Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Higashida, Y.
Right arrow Articles by Yamashita, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Higashida, Y.
Right arrow Articles by Yamashita, J.

Radiology, Vol 183, 483-486, Copyright © 1992 by Radiological Society of North America


ARTICLES

Detection of subtle microcalcifications: comparison of computed radiography and screen-film mammography

Y Higashida, N Moribe, K Morita, N Katsuda, M Hatemura, T Takada, M Takahashi and J Yamashita
Department of Radiological Technology, Kumamoto University College of Medical Science, Japan.

Observer performance tests were conducted to compare the effects of image-processing technique (unsharp mask filtering) on the diagnostic accuracy of computed radiography (CR) with storage phosphors in the detection of microcalcifications. Comparison of detectability of microcalcifications with CR and with screen-film mammography was also performed. Clusters of microcalcifications (125-250 microns in diameter) were randomly superimposed on human breast specimens. Observer performance tests were carried out with receiver operating characteristic (ROC) analysis. The area under the ROC curve and the cumulative true-positive-localization fraction were both used as indexes of performance. Observer performance experiments with nine observers indicated that the two types of screen-film images used provided higher detectability than the CR images. The detectability of microcalcifications on the CR images improved slightly with use of the unsharp masking technique. However, no statistically significant difference was found between processed and unprocessed CR images, and detectability still did not reach the level achieved with the screen- film images.


This article has been cited by other articles:


Home page
J. Neurol. Neurosurg. PsychiatryHome page
M S A Deloire, E Salort, M Bonnet, Y Arimone, M Boudineau, H Amieva, B Barroso, J-C Ouallet, C Pachai, E Galliaud, et al.
Cognitive impairment as marker of diffuse brain abnormalities in early relapsing remitting multiple sclerosis
J. Neurol. Neurosurg. Psychiatry, April 1, 2005; 76(4): 519 - 526.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. Iinuma, K. Ushio, T. Ishikawa, S. Nawano, R. Sekiguchi, and M. Satake
Diagnosis of Gastric Cancers: Comparison of Conventional Radiography and Digital Radiography with a 4 Million-Pixel Charge-coupled Device
Radiology, February 1, 2000; 214(2): 497 - 502.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1992 by the Radiological Society of North America.