Radiology, Vol 183, 741-744, Copyright © 1992 by Radiological Society of North America
ARTICLES |
E Casalini
Department of Radiology, Istituti Clinici di Perfezionamento, Milan, Italy.
Numerous in vitro studies have found that clot formation may occur when blood is mixed directly with nonionic low-osmolality contrast media during angiographic procedures because of activation of hemostasis in the catheter; ionic contrast media, on the other hand, inhibit clot formation. Thirty patients were injected with low-osmolality contrast media--15 with ioxaglate, an ionic dimer, and 15 with iopamidol, a nonionic monomer. The inner wall of the angiographic catheter was studied with electron microscopy after selective catheterization of supraaortic vessels. Clot formation of various extent was observed in nine (60%) of the patients administered iopamidol. No coagulation process was found in the catheters of the patients administered ioxaglate. Results indicate that nonionic, low-osmolality contrast media may play a role in the formation of thromboembolisms.
This article has been cited by other articles:
![]() |
B. Scheller A reply Eur. Heart J., January 2, 2002; 23(2): 173 - 175. [Full Text] [PDF] |
||||
![]() |
B Scheller, B Hennen, A Pohl, H Schieffer, and T Markwirth Acute and subacute stent occlusion; risk-reduction by ionic contrast media Eur. Heart J., March 1, 2001; 22(5): 385 - 391. [Abstract] [PDF] |
||||