Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Muhler, A.
Right arrow Articles by Brasch, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Muhler, A.
Right arrow Articles by Brasch, R. C.

Radiology, Vol 184, 207-213, Copyright © 1992 by Radiological Society of North America


ARTICLES

Hepatobiliary enhancement with Gd-EOB-DTPA: comparison of spin-echo and STIR imaging for detection of experimental liver metastases

A Muhler, O Clement, V Vexler, Y Berthezene, W Rosenau and RC Brasch
Department of Radiology, University of California San Francisco 94143- 0628.

Gadolinium (4S)-4-(4-ethoxybenzyl)-3,6,9-tris(carboxylatomethyl)-3,6,9- triazaundecandioic acid-disodium salt (EOB-DTPA) ethoxybenzyl is a new hepatobiliary magnetic resonance (MR) contrast agent with dual elimination: 75% through the liver and bile and 25% through the kidneys in normal rats. In this study, Gd-EOB-DTPA was evaluated in a rodent model of metastatic liver disease to measure both relative enhancement and lesion-to-liver contrast. A secondary goal was to compare the relative performance of spin-echo (SE) and short inversion time inversion-recovery (STIR) imaging to demonstrate enhancement with Gd- EOB-DTPA. After administration of 0.1 mmol of Gd-EOB-DTPA per kilogram, liver signal increased (positive enhancement) more than 200% with the use of the SE technique and declined (negative enhancement) by more than 80% with use of the STIR technique. Only minimal enhancement of implanted liver tumor was observed. Unlike the tumor, the gall-bladder and lumen of the duodenum were progressively enhanced over time. The lesion-to-liver contrast increased by approximately 500% with both the SE and STIR techniques after administration of Gd-EOB-DTPA.