Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schaefer, C. M.
Right arrow Articles by Galanski, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schaefer, C. M.
Right arrow Articles by Galanski, M.

Radiology, Vol 184, 77-81, Copyright © 1992 by Radiological Society of North America


ARTICLES

Impact of hard-copy size on observer performance in digital chest radiography

CM Schaefer, M Prokop, JW Oestmann, W Wiesmann, B Haubitz, A Meschede, S Reichelt, E Schirg, HS Stender and M Galanski
Department of Radiology, Medizinische Hochschule Hannover, Germany.

To determine the impact of reduced hard-copy size on diagnostic performance of digital radiography, screen-film chest radiographs were compared with isodose digital storage phosphor radiographs in the detection of simulated nodules, fine pulmonary lines, and micronodular opacities superimposed on the chests of 10 healthy volunteers. Digital radiographs were laser-printed in a full-size conventional format and in image lengths of two-thirds, one-half, and five-elevenths of the conventional format. Eighteen thousand observations by eight radiologists were analyzed by use of receiver operating characteristics. The detectability of lines and micronodular opacities decreased with declining image format size. In the detection of micronodular opacities, only the nearly full-size digital images were equivalent to conventional images. In the detection of linear opacities, reduction of image length by one-half or more reduced performance (analysis of variance, P less than .05). Only for the detection of nodules was no major difference found.


This article has been cited by other articles:


Home page
JOURNAL OF THE ICRUHome page
References
J. ICRU, April 1, 2008; 8(1): 57 - 62.
[PDF]


Home page
RadiologyHome page
S. P. M. Miró, A. N. Leung, G. D. Rubin, Y. H. Choi, S. T. Kee, R. E. Mindelzun, P. Stark, L. Wexler, S. K. Plevritis, and B. J. Betts
Digital Storage Phosphor Chest Radiography: An ROC Study of the Effect of 2K versus 4K Matrix Size on Observer Performance
Radiology, February 1, 2001; 218(2): 527 - 532.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1992 by the Radiological Society of North America.