Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maurer, A. H.
Right arrow Articles by Krevsky, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maurer, A. H.
Right arrow Articles by Krevsky, B.

Radiology, Vol 185, 187-192, Copyright © 1992 by Radiological Society of North America


ARTICLES

Gastrointestinal bleeding: improved localization with cine scintigraphy

AH Maurer, MS Rodman, RA Vitti, G Revez and B Krevsky
Department of Diagnostic Imaging, Temple University Hospital, Philadelphia, PA 19140.

Studies of gastrointestinal bleeding, done with technetium-99m-labeled red blood cells were performed in 52 consecutive patients to determine whether cinematic acquisition and display localized sites of bleeding more accurately than did conventional static imaging. Computerized images were obtained for 15 seconds per image in 15-minute sets. Interpretations based on a cinematic display were compared with those based on standard 1-minute images obtained every 5 minutes. Pathologic confirmation of a site of bleeding was obtained in 21 patients. The cinematic display demonstrated bleeding not seen on static images and yielded either more accurate localization or increased sensitivity in eight of 21 patients (38%). Linear regression showed that the cinematic correlation (r = .98) to the actual site of bleeding was better than either of two readers' interpretations of the static display (r = .93, P less than .02; and r = .88, P less than .0004). The mean error for cinematic localization of bleeding (0.4 anatomic segments +/- 0.6 [standard deviation]) was less than that for the static interpretations (1.1 anatomic segments +/- 1.4) (P less than .01). It is concluded that computerized cinematic acquisition and display of scintigrams improves localization and detection of gastrointestinal bleeding.


This article has been cited by other articles:


Home page
JNMHome page
G. Mariani, E. K.J. Pauwels, A. AlSharif, S. Marchi, G. Boni, M. Barreca, M. Bellini, M. Grosso, N. de Bortoli, G. Mumolo, et al.
Radionuclide Evaluation of the Lower Gastrointestinal Tract
J. Nucl. Med., May 1, 2008; 49(5): 776 - 787.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
B. R. Krynyckyi, C. K. Kim, M. R. Goyenechea, P. T. Chan, Z.-Y. Zhang, and J. Machac
Clinical Breast Lymphoscintigraphy: Optimal Techniques for Performing Studies, Image Atlas, and Analysis of Images
RadioGraphics, January 1, 2004; 24(1): 121 - 145.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
L. E. Holder
Radionuclide Imaging in the Evaluation of Acute Gastrointestinal Bleeding
RadioGraphics, July 1, 2000; 20(4): 1153 - 1159.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1992 by the Radiological Society of North America.