Radiology, Vol 185, 29-35, Copyright © 1992 by Radiological Society of North America
ARTICLES |
A Polacin, WA Kalender and G Marchal
Siemens Medical Systems, Erlangen, Germany.
Spiral computed tomography (CT) offers continuous volume scanning of complete organs or body sections within a single breath hold. Almost all image quality characteristics of spiral CT are identical to those of conventional section-by-section CT; however, there is a change in pixel noise values and degradation in the shape of the section sensitivity profiles (SSPs). Computer simulations, phantom measurements, and clinical studies were used in evaluating the SSP and noise characteristics of two new section-interpolation algorithms. The results were compared with standard CT and spiral CT data processed with the commonly employed linear section-interpolation algorithm. Degradation of SSP quality was insignificant for a table feed distance per 360 degrees revolution equal to the section thickness when the new algorithms were applied; noise values, however, increased. SSP width increased for table feed distances greater than the section width, the effect being less pronounced with the new algorithms. The value of these algorithms is primarily seen in the improved quality of multiplanar reformations and cine and three-dimensional displays.
This article has been cited by other articles:
![]() |
R. Grosjean, B. Sauer, R. M. Guerra, M. Daudon, A. Blum, J. Felblinger, and J. Hubert Characterization of Human Renal Stones with MDCT: Advantage of Dual Energy and Limitations Due to Respiratory Motion Am. J. Roentgenol., March 1, 2008; 190(3): 720 - 728. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. N. Primak, C. H. McCollough, M. R. Bruesewitz, J. Zhang, and J. G. Fletcher Relationship between Noise, Dose, and Pitch in Cardiac Multi-Detector Row CT RadioGraphics, November 1, 2006; 26(6): 1785 - 1794. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. C. Dalrymple, S. R. Prasad, M. W. Freckleton, and K. N. Chintapalli Informatics in Radiology (infoRAD): Introduction to the Language of Three-dimensional Imaging with Multidetector CT RadioGraphics, September 1, 2005; 25(5): 1409 - 1428. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. G. Flohr, S. Schaller, K. Stierstorfer, H. Bruder, B. M. Ohnesorge, and U. J. Schoepf Multi-Detector Row CT Systems and Image-Reconstruction Techniques Radiology, June 1, 2005; 235(3): 756 - 773. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Mayo, J. Aldrich, and N. L. Muller Radiation Exposure at Chest CT: A Statement of the Fleischner Society Radiology, July 1, 2003; 228(1): 15 - 21. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kozuka, T. Johkoh, S. Hamada, H. Naito, N. Tomiyama, M. Koyama, N. Mihara, O. Honda, H. Nakamura, and M. Kudo Detection of Pulmonary Metastases with Multi-Detector Row CT Scans of 5-mm Nominal Section Thickness: Autopsy Lung Study Radiology, January 1, 2003; 226(1): 231 - 234. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Engelke, C. Schaefer-Prokop, E. Schirg, J. Freihorst, S. Grubnic, and M. Prokop High-Resolution CT and CT Angiography of Peripheral Pulmonary Vascular Disorders RadioGraphics, July 1, 2002; 22(4): 739 - 764. [Abstract] [Full Text] [PDF] |
||||
![]() |
E T H Wong, S K Yu, M Lai, Y C Wong, and P C Lau MAPD--an objective way to select mAs for paediatric brain CT Br. J. Radiol., October 1, 2001; 74(886): 932 - 937. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. R. Whiting, E. G. McFarland, and J. A. Brink Influence of Image Acquisition Parameters on CT Artifacts and Polyp Depiction in Spiral CT Colonography: In Vitro Evaluation Radiology, October 1, 2000; 217(1): 165 - 172. [Abstract] [Full Text] |
||||
![]() |
B. C. Vande Berg, F. E. Lecouvet, P. Poilvache, J.-E. Dubuc, B. Bedat, B. Maldague, J.-J. Rombouts, and J. Malghem Dual-Detector Spiral CT Arthrography of the Knee: Accuracy for Detection of Meniscal Abnormalities and Unstable Meniscal Tears Radiology, September 1, 2000; 216(3): 851 - 857. [Abstract] [Full Text] |
||||
![]() |
D. Fleischmann, G. D. Rubin, D. S. Paik, S. Y. Yen, P. R. Hilfiker, C. F. Beaulieu, and S. Napel Stair-Step Artifacts with Single versus Multiple Detector-Row Helical CT Radiology, July 1, 2000; 216(1): 185 - 196. [Abstract] [Full Text] |
||||
![]() |
G. D. Rubin, M. C. Shiau, A. N. Leung, S. T. Kee, L. J. Logan, and M. C. Sofilos Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography Radiology, June 1, 2000; 215(3): 670 - 676. [Abstract] [Full Text] |
||||
![]() |
H. Hu, H. D. He, W. D. Foley, and S. H. Fox Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed Radiology, April 1, 2000; 215(1): 55 - 62. [Abstract] [Full Text] |
||||
![]() |
C. H. Coulam, D. H. Sheafor, R. A. Leder, E. K. Paulson, D. M. DeLong, and R. C. Nelson Evaluation of Pseudoenhancement of Renal Cysts During Contrast-Enhanced CT Am. J. Roentgenol., February 1, 2000; 174(2): 493 - 498. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Brink, G. Wang, and E. G. McFarland Optimal Section Spacing in Single-Detector Helical CT Radiology, February 1, 2000; 214(2): 575 - 578. [Abstract] [Full Text] |
||||
![]() |
H. Azhari and D. Sazbon Volumetric Imaging with Ultrasonic Spiral CT Radiology, July 1, 1999; 212(1): 270 - 275. [Abstract] [Full Text] |
||||
![]() |
X. Leclerc, O. Godefroy, C. Lucas, J.-F. Benhaim, T. S. Michel, D. Leys, and J. P. Pruvo Internal Carotid Arterial Stenosis: CT Angiography with Volume Rendering Radiology, March 1, 1999; 210(3): 673 - 682. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |