Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Polacin, A.
Right arrow Articles by Marchal, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Polacin, A.
Right arrow Articles by Marchal, G.

Radiology, Vol 185, 29-35, Copyright © 1992 by Radiological Society of North America


ARTICLES

Evaluation of section sensitivity profiles and image noise in spiral CT

A Polacin, WA Kalender and G Marchal
Siemens Medical Systems, Erlangen, Germany.

Spiral computed tomography (CT) offers continuous volume scanning of complete organs or body sections within a single breath hold. Almost all image quality characteristics of spiral CT are identical to those of conventional section-by-section CT; however, there is a change in pixel noise values and degradation in the shape of the section sensitivity profiles (SSPs). Computer simulations, phantom measurements, and clinical studies were used in evaluating the SSP and noise characteristics of two new section-interpolation algorithms. The results were compared with standard CT and spiral CT data processed with the commonly employed linear section-interpolation algorithm. Degradation of SSP quality was insignificant for a table feed distance per 360 degrees revolution equal to the section thickness when the new algorithms were applied; noise values, however, increased. SSP width increased for table feed distances greater than the section width, the effect being less pronounced with the new algorithms. The value of these algorithms is primarily seen in the improved quality of multiplanar reformations and cine and three-dimensional displays.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
R. Grosjean, B. Sauer, R. M. Guerra, M. Daudon, A. Blum, J. Felblinger, and J. Hubert
Characterization of Human Renal Stones with MDCT: Advantage of Dual Energy and Limitations Due to Respiratory Motion
Am. J. Roentgenol., March 1, 2008; 190(3): 720 - 728.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
A. N. Primak, C. H. McCollough, M. R. Bruesewitz, J. Zhang, and J. G. Fletcher
Relationship between Noise, Dose, and Pitch in Cardiac Multi-Detector Row CT
RadioGraphics, November 1, 2006; 26(6): 1785 - 1794.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
N. C. Dalrymple, S. R. Prasad, M. W. Freckleton, and K. N. Chintapalli
Informatics in Radiology (infoRAD): Introduction to the Language of Three-dimensional Imaging with Multidetector CT
RadioGraphics, September 1, 2005; 25(5): 1409 - 1428.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. G. Flohr, S. Schaller, K. Stierstorfer, H. Bruder, B. M. Ohnesorge, and U. J. Schoepf
Multi-Detector Row CT Systems and Image-Reconstruction Techniques
Radiology, June 1, 2005; 235(3): 756 - 773.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. R. Mayo, J. Aldrich, and N. L. Muller
Radiation Exposure at Chest CT: A Statement of the Fleischner Society
Radiology, July 1, 2003; 228(1): 15 - 21.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Kozuka, T. Johkoh, S. Hamada, H. Naito, N. Tomiyama, M. Koyama, N. Mihara, O. Honda, H. Nakamura, and M. Kudo
Detection of Pulmonary Metastases with Multi-Detector Row CT Scans of 5-mm Nominal Section Thickness: Autopsy Lung Study
Radiology, January 1, 2003; 226(1): 231 - 234.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. Engelke, C. Schaefer-Prokop, E. Schirg, J. Freihorst, S. Grubnic, and M. Prokop
High-Resolution CT and CT Angiography of Peripheral Pulmonary Vascular Disorders
RadioGraphics, July 1, 2002; 22(4): 739 - 764.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E T H Wong, S K Yu, M Lai, Y C Wong, and P C Lau
MAPD--an objective way to select mAs for paediatric brain CT
Br. J. Radiol., October 1, 2001; 74(886): 932 - 937.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. R. Whiting, E. G. McFarland, and J. A. Brink
Influence of Image Acquisition Parameters on CT Artifacts and Polyp Depiction in Spiral CT Colonography: In Vitro Evaluation
Radiology, October 1, 2000; 217(1): 165 - 172.
[Abstract] [Full Text]


Home page
RadiologyHome page
B. C. Vande Berg, F. E. Lecouvet, P. Poilvache, J.-E. Dubuc, B. Bedat, B. Maldague, J.-J. Rombouts, and J. Malghem
Dual-Detector Spiral CT Arthrography of the Knee: Accuracy for Detection of Meniscal Abnormalities and Unstable Meniscal Tears
Radiology, September 1, 2000; 216(3): 851 - 857.
[Abstract] [Full Text]


Home page
RadiologyHome page
D. Fleischmann, G. D. Rubin, D. S. Paik, S. Y. Yen, P. R. Hilfiker, C. F. Beaulieu, and S. Napel
Stair-Step Artifacts with Single versus Multiple Detector-Row Helical CT
Radiology, July 1, 2000; 216(1): 185 - 196.
[Abstract] [Full Text]


Home page
RadiologyHome page
G. D. Rubin, M. C. Shiau, A. N. Leung, S. T. Kee, L. J. Logan, and M. C. Sofilos
Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography
Radiology, June 1, 2000; 215(3): 670 - 676.
[Abstract] [Full Text]


Home page
RadiologyHome page
H. Hu, H. D. He, W. D. Foley, and S. H. Fox
Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Radiology, April 1, 2000; 215(1): 55 - 62.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
C. H. Coulam, D. H. Sheafor, R. A. Leder, E. K. Paulson, D. M. DeLong, and R. C. Nelson
Evaluation of Pseudoenhancement of Renal Cysts During Contrast-Enhanced CT
Am. J. Roentgenol., February 1, 2000; 174(2): 493 - 498.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. A. Brink, G. Wang, and E. G. McFarland
Optimal Section Spacing in Single-Detector Helical CT
Radiology, February 1, 2000; 214(2): 575 - 578.
[Abstract] [Full Text]


Home page
RadiologyHome page
H. Azhari and D. Sazbon
Volumetric Imaging with Ultrasonic Spiral CT
Radiology, July 1, 1999; 212(1): 270 - 275.
[Abstract] [Full Text]


Home page
RadiologyHome page
X. Leclerc, O. Godefroy, C. Lucas, J.-F. Benhaim, T. S. Michel, D. Leys, and J. P. Pruvo
Internal Carotid Arterial Stenosis: CT Angiography with Volume Rendering
Radiology, March 1, 1999; 210(3): 673 - 682.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1992 by the Radiological Society of North America.