Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Geleijns, J.
Right arrow Articles by Kool, L. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Geleijns, J.
Right arrow Articles by Kool, L. J.

Radiology, Vol 185, 719-723, Copyright © 1992 by Radiological Society of North America


ARTICLES

AMBER and conventional chest radiography: comparison of radiation dose and image quality

J Geleijns, JJ Broerse, HW Julius, HA Vrooman, J Zoetelief, D Zweers and LJ Kool
Department of Clinical Oncology, University Hospital Leiden, The Netherlands.

The authors compared the radiation dose to the patient and the image quality in advanced multiple-beam equalization radiography (AMBER) with those in conventional chest radiography. Organ doses were estimated for an anthropomorphic phantom from measurements with thermoluminescence dosimeters. These measurements were supplemented with area-air kerma products obtained during chest examinations of 223 patients. Image quality was determined by means of a contrast-detail image evaluation test. An improvement in image quality in regions of high absorption and an increased dose to the patient were found for the AMBER technique compared with the conventional technique. However, for both techniques, the radiation exposure was relatively low compared with other reported values of patient dose during chest radiography. The estimated effective dose for an average-size patient during chest radiography with posteroanterior and lateral projections is 0.085 mSv for the conventional and 0.14 mSv for the AMBER technique.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
R T M van Soldt, D Zweers, L van den Berg, J Geleijns, J T. M Jansen, and J Zoetelief
Survey of posteroanterior chest radiography in The Netherlands: patient dose and image quality