Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chotas, H. G.
Right arrow Articles by Ravin, C. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chotas, H. G.
Right arrow Articles by Ravin, C. E.

Radiology, Vol 186, 395-398, Copyright © 1993 by Radiological Society of North America


ARTICLES

Digital chest radiography with photostimulable storage phosphors: signal-to-noise ratio as a function of kilovoltage with matched exposure risk

HG Chotas, CE Floyd Jr, JT Dobbins 3d and CE Ravin
Department of Radiology, Duke University Medical Center, Durham, NC 27710.

A photostimulable storage phosphor (PSP) digital radiography system was evaluated regarding the signal-to-noise ratio (S/N) on chest images acquired at differing peak kilovoltage settings but with matched risk from radiation exposure. Images of two chest phantoms were acquired by using bedside (portable) imaging equipment at tube voltages ranging from 60 to 120 kV. Exposure factors were set so that the effective dose equivalent, a risk estimator weighted for various organs, was approximately equal in all exposures. The S/N in the lung-equivalent regions was found to be slightly higher (maximum, 15%) in the low- energy exposures, while the S/N values in the mediastinum- and subdiaphragm-equivalent regions were approximately equal at all kilovoltage settings. The absence of a high sensitivity of S/N to kilovoltage in risk-matched PSP images should enable institutions to select x-ray beam quality on the basis of other imaging criteria.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
E Alpoz, E Sogur, and B. Baksi Akdeniz
Perceptibility curve test for digital radiographs before and after application of various image processing algorithms
Dentomaxillofac. Radiol., December 1, 2007; 36(8): 490 - 494.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
C S Moore, G P Liney, A W Beavis, and J R Saunderson
A method to optimize the processing algorithm of a computed radiography system for chest radiography
Br. J. Radiol., September 1, 2007; 80(957): 724 - 730.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
H Warren-Forward, L Arthur, L Hobson, R Skinner, A Watts, K Clapham, D Lou, and A Cook
An assessment of exposure indices in computed radiography for the posterior-anterior chest and the lateral lumbar spine
Br. J. Radiol., January 1, 2007; 80(949): 26 - 31.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
O. W. Hamer, C. B. Sirlin, M. Strotzer, I. Borisch, N. Zorger, S. Feuerbach, and M. Volk
Chest Radiography with a Flat-Panel Detector: Image Quality with Dose Reduction after Copper Filtration
Radiology, November 1, 2005; 237(2): 691 - 700.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
A. Tingberg and D. Sjostrom
Optimisation of image plate radiography with respect to tube voltage
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 286 - 293.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
I D Honey, A Mackenzie, and D S Evans
Investigation of optimum energies for chest imaging using film-screen and computed radiography
Br. J. Radiol., May 1, 2005; 78(929): 422 - 427.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Uffmann, U. Neitzel, M. Prokop, N. Kabalan, M. Weber, C. J. Herold, and C. Schaefer-Prokop
Flat-Panel-Detector Chest Radiography: Effect of Tube Voltage on Image Quality
Radiology, May 1, 2005; 235(2): 642 - 650.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. M. Bernhardt, U. Rapp-Bernhardt, H. Lenzen, F. W. Roehl, S. Diederich, K. Papke, K. Ludwig, and W. Heindel
Low-Voltage Digital Selenium Radiography: Detection of Simulated Interstitial Lung Disease, Nodules, and Catheters--A Phantom Study
Radiology, September 1, 2004; 232(3): 693 - 700.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. T. Dobbins III, E. Samei, H. G. Chotas, R. J. Warp, A. H. Baydush, C. E. Floyd Jr, and C. E. Ravin
Chest Radiography: Optimization of X-ray Spectrum for Cesium Iodide-Amorphous Silicon Flat-Panel Detector
Radiology, January 1, 2003; 226(1): 221 - 230.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.