Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kreft, B. P.
Right arrow Articles by Stark, D. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kreft, B. P.
Right arrow Articles by Stark, D. D.

Radiology, Vol 186, 543-548, Copyright © 1993 by Radiological Society of North America


ARTICLES

Orally administered manganese chloride: enhanced detection of hepatic tumors in rats

BP Kreft, Y Baba, A Tanimoto, JP Finn and DD Stark
Department of Radiology, University of Bonn, Germany.

To evaluate its potential as a tissue-specific hepatobiliary magnetic resonance (MR) contrast agent, manganese chloride was orally administered to rats in increasing doses of 100-1,500 mumol/kg MnCl2, and the relaxation times of liver, pancreas, kidney, and heart were measured with ex vivo relaxometry and in vivo MR imaging. Two hours after ingestion of 200 mumol/kg MnCl2, liver T1 was decreased by 48%, whereas tumor T1 decreased by only 9%. On spin-echo MR images, the signal-to-noise ratio in liver increased by 54%; the contrast-to-noise ratio in tumor, by 375%. The T1 of pancreas, kidney, and heart decreased by 8%, 23%, and 13%, respectively. At subjective assessment, the signal intensity of the upper gastrointestinal tract was reduced, likely because of the high concentration of manganese in the lumen, and delineation of the intestine from other abdominal structures was improved. These results indicate that orally administered MnCl2 causes substantial, reproducible, and tissue-specific enhancement of liver. Because enhancement of tumor was minimal, orally administered MnCl2 may potentially be used to improve detection of hepatic tumors.


This article has been cited by other articles:


Home page
IOVSHome page
S. K. Li, E.-K. Jeong, and M. S. Hastings
Magnetic Resonance Imaging Study of Current and Ion Delivery into the Eye during Transscleral and Transcorneal Iontophoresis
Invest. Ophthalmol. Vis. Sci., April 1, 2004; 45(4): 1224 - 1231.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.