Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lin, W.
Right arrow Articles by Masaryk, T. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lin, W.
Right arrow Articles by Masaryk, T. J.

Radiology, Vol 186, 753-761, Copyright © 1993 by Radiological Society of North America


ARTICLES

Intracranial MR angiography: application of magnetization transfer contrast and fat saturation to short gradient-echo, velocity- compensated sequences

W Lin, JA Tkach, EM Haacke and TJ Masaryk
Department of Radiology, MRI, University Hospitals of Cleveland, OH 44106.

To circumvent artifacts related to saturation, turbulence, and data processing in three-dimensional (3D) time-of-flight (TOF) magnetic resonance (MR) angiography, the authors used a high-resolution (256 x 512), short, asymmetric velocity-compensated gradient-echo sequence, magnetization transfer contrast (MTC) between all excitation pulses to suppress brain parenchyma signal, and frequency-offset fat saturation (FS) to suppress fat signal. Signal intensity and blood-background contrast was measured in several regions of interest on conventional 3D TOF MR images, MTC images, and those with MTC and FS in seven volunteers. One patient each with an arteriovenous malformation, an aneurysm, and stenosis in the intracranial vascular system underwent the protocols with an echo time (TE) of 5 msec and then a TE of 8 msec. Use of the 5-msec-TE sequence with MTC and FS led to reduced problems associated with signal void in areas of fast flow in patients. In volunteers and patients, vascular visualization was superior to that of current 3D TOF techniques.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. Nael, J. P. Villablanca, L. Mossaz, W. Pope, A. Juncosa, G. Laub, and J. P. Finn
3-T Contrast-Enhanced MR Angiography in Evaluation of Suspected Intracranial Aneurysm: Comparison with MDCT Angiography
Am. J. Roentgenol., February 1, 2008; 190(2): 389 - 395.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
K. Nael, J.P. Villablanca, R. Saleh, W. Pope, A. Nael, G. Laub, and J.P. Finn
Contrast-Enhanced MR Angiography at 3T in the Evaluation of Intracranial Aneurysms: A Comparison with Time-of-Flight MR Angiography
AJNR Am. J. Neuroradiol., November 1, 2006; 27(10): 2118 - 2121.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
W. M. Adams, R. D. Laitt, and A. Jackson
The Role of MR Angiography in the Pretreatment Assessment of Intracranial Aneurysms: A Comparative Study
AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1618 - 1628.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
S. Ouanounou, T. A. Tomsick, C. Heitsman, and C. K. Holland
Cavernous Sinus and Inferior Petrosal Sinus Flow Signal on Three-Dimensional Time-of-Flight MR Angiography
AJNR Am. J. Neuroradiol., September 1, 1999; 20(8): 1476 - 1481.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
J. S. Ross
Newer Sequences for Spinal MR Imaging: Smorgasbord or Succotash of Acronyms?
AJNR Am. J. Neuroradiol., March 1, 1999; 20(3): 361 - 373.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.