|
|
||||||||
Radiology, Vol 186, 753-761, Copyright © 1993 by Radiological Society of North America
ARTICLES |
W Lin, JA Tkach, EM Haacke and TJ Masaryk
Department of Radiology, MRI, University Hospitals of Cleveland, OH 44106.
To circumvent artifacts related to saturation, turbulence, and data processing in three-dimensional (3D) time-of-flight (TOF) magnetic resonance (MR) angiography, the authors used a high-resolution (256 x 512), short, asymmetric velocity-compensated gradient-echo sequence, magnetization transfer contrast (MTC) between all excitation pulses to suppress brain parenchyma signal, and frequency-offset fat saturation (FS) to suppress fat signal. Signal intensity and blood-background contrast was measured in several regions of interest on conventional 3D TOF MR images, MTC images, and those with MTC and FS in seven volunteers. One patient each with an arteriovenous malformation, an aneurysm, and stenosis in the intracranial vascular system underwent the protocols with an echo time (TE) of 5 msec and then a TE of 8 msec. Use of the 5-msec-TE sequence with MTC and FS led to reduced problems associated with signal void in areas of fast flow in patients. In volunteers and patients, vascular visualization was superior to that of current 3D TOF techniques.
This article has been cited by other articles:
![]() |
K. Nael, J. P. Villablanca, L. Mossaz, W. Pope, A. Juncosa, G. Laub, and J. P. Finn 3-T Contrast-Enhanced MR Angiography in Evaluation of Suspected Intracranial Aneurysm: Comparison with MDCT Angiography Am. J. Roentgenol., February 1, 2008; 190(2): 389 - 395. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nael, J.P. Villablanca, R. Saleh, W. Pope, A. Nael, G. Laub, and J.P. Finn Contrast-Enhanced MR Angiography at 3T in the Evaluation of Intracranial Aneurysms: A Comparison with Time-of-Flight MR Angiography AJNR Am. J. Neuroradiol., November 1, 2006; 27(10): 2118 - 2121. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. M. Adams, R. D. Laitt, and A. Jackson The Role of MR Angiography in the Pretreatment Assessment of Intracranial Aneurysms: A Comparative Study AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1618 - 1628. [Abstract] [Full Text] |
||||
![]() |
S. Ouanounou, T. A. Tomsick, C. Heitsman, and C. K. Holland Cavernous Sinus and Inferior Petrosal Sinus Flow Signal on Three-Dimensional Time-of-Flight MR Angiography AJNR Am. J. Neuroradiol., September 1, 1999; 20(8): 1476 - 1481. [Abstract] [Full Text] |
||||
![]() |
J. S. Ross Newer Sequences for Spinal MR Imaging: Smorgasbord or Succotash of Acronyms? AJNR Am. J. Neuroradiol., March 1, 1999; 20(3): 361 - 373. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |