Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Low, R. N.
Right arrow Articles by Foo, T. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Low, R. N.
Right arrow Articles by Foo, T. K.

Radiology, Vol 186, 803-811, Copyright © 1993 by Radiological Society of North America


ARTICLES

Abdominal MR imaging: comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient- recalled imaging

RN Low, IR Francis, JS Sigeti and TK Foo
Sharp and Children's MRI Center/San Diego Diagnostic Radiology, CA 92123-2740.

T2-weighted fast and conventional spin-echo (SE) and dynamic gadolinium- enhanced fast multiplanar spoiled gradient-recalled (FMPSPGR) images in 26 patients (18 with hepatic masses and eight with no detected abnormality) were compared to determine the efficacy of the newer pulse sequences (fast SE and FMPSPGR) in abdominal imaging. FMPSPGR allows for breath-hold magnetic resonance imaging of the liver. The contrast- to-noise ratio (C/N) of the hepatic lesions was calculated for each sequence and was superior in fast SE compared with that in conventional SE in 16 of 18 patients. Lesion detection was 90% with fast SE and was 85% and 80% for conventional SE and contrast material-enhanced FMPSPGR sequences, respectively. Of the T2-weighted sequences, fast SE showed consistently sharper anatomic structures and less respiratory and cardiac motion artifact. Thus, fast SE (with its superior C/N and shorter imaging time) and gadolinium-enhanced FMPSPGR images, when combined, demonstrate potential value as routine sequences in abdominal imaging.


This article has been cited by other articles:


Home page
RadiologyHome page
T. Parikh, S. J. Drew, V. S. Lee, S. Wong, E. M. Hecht, J. S. Babb, and B. Taouli
Focal Liver Lesion Detection and Characterization with Diffusion-weighted MR Imaging: Comparison with Standard Breath-hold T2-weighted Imaging
Radiology, March 1, 2008; 246(3): 812 - 822.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Kanematsu, S. Goshima, H. Kondo, Y. Tsuge, R. Yokoyama, K. Kajita, M. Onozuka, Y. Suzuki, M. Van Cauteren, and N. Moriyama
Gadolinium-Enhanced Multiphasic 3D MRI of the Liver with Prospective Adaptive Navigator Correction: Phantom Study and Preliminary Clinical Evaluation
Am. J. Roentgenol., April 1, 2007; 188(4): W309 - W316.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. K. Hussain, I. Syed, H. V. Nghiem, T. D. Johnson, R. C. Carlos, W. J. Weadock, and I. R. Francis
T2-weighted MR Imaging in the Assessment of Cirrhotic Liver
Radiology, March 1, 2004; 230(3): 637 - 644.
[Abstract] [Full Text] [PDF]


Home page
Cancer Res.Home page
M. Wu, R. Mazurchuk, N. D. Chaudhary, J. Spernyak, J. Veith, P. Pera, W. Greco, R. M. Hoffman, T. Kobayashi, and R. J. Bernacki
High-Resolution Magnetic Resonance Imaging of the Efficacy of the Cytosine Analogue 1-[2-C-Cyano-2-deoxy-{beta}-D-arabino-pentofuranosyl]-N4-palmitoyl Cytosine (CS-682) in a Liver-Metastasis Athymic Nude Mouse Model
Cancer Res., May 15, 2003; 63(10): 2477 - 2482.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Kanematsu, R. C. Semelka, M. Matsuo, H. Kondo, M. Enya, S. Goshima, N. Moriyama, and H. Hoshi
Gadolinium-enhanced MR Imaging of the Liver: Optimizing Imaging Delay for Hepatic Arterial and Portal Venous Phases—A Prospective Randomized Study in Patients with Chronic Liver Damage
Radiology, November 1, 2002; 225(2): 407 - 415.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Y. Jeong, D. G. Mitchell, and G. A. Holland
Liver Lesion Conspicuity: T2-weighted Breath-hold Fast Spin-Echo MR Imaging before and after Gadolinium Enhancement—Initial Experience
Radiology, May 1, 2001; 219(2): 455 - 460.
[Abstract] [Full Text]


Home page
RadiologyHome page
R. C. Semelka and T. K. G. Helmberger
Contrast Agents for MR Imaging of the Liver
Radiology, January 1, 2001; 218(1): 27 - 38.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
M. Scialpi, A. Di Maggio, M. Midiri, A. Loperfido, G. Angelelli, and A. Rotondo
Small Renal Masses: Assessment of Lesion Characterization and Vascularity on Dynamic Contrast-Enhanced MR Imaging with Fat Suppression
Am. J. Roentgenol., September 1, 2000; 175(3): 751 - 757.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. A. Soto, O. Alvarez, J. E. Lopera, F. Munera, J. C. Restrepo, and G. Correa
Biliary Obstruction: Findings at MR Cholangiography and Cross-sectional MR Imaging
RadioGraphics, March 1, 2000; 20(2): 353 - 366.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Kanematsu, H. Hoshi, K. Itoh, T. Murakami, M. Hori, H. Kondo, R. Yokoyama, and H. Nakamura
Focal Hepatic Lesion Detection: Comparison of Four Fat-suppressed T2-weighted MR Imaging Pulse Sequences
Radiology, May 1, 1999; 211(2): 363 - 371.
[Abstract] [Full Text]


Home page
RadiologyHome page
R. N. Low, R. C. Semelka, S. Worawattanakul, G. D. Alzate, and J. S. Sigeti
Extrahepatic Abdominal Imaging in Patients with Malignancy: Comparison of MR Imaging and Helical CT, with Subsequent Surgical Correlation
Radiology, March 1, 1999; 210(3): 625 - 632.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.