Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bogdanov, A. A.
Right arrow Articles by Brady, T. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bogdanov, A. A., Jr
Right arrow Articles by Brady, T. J.

Radiology, Vol 187, 701-706, Copyright © 1993 by Radiological Society of North America


ARTICLES

A new macromolecule as a contrast agent for MR angiography: preparation, properties, and animal studies

AA Bogdanov Jr, R Weissleder, HW Frank, AV Bogdanova, N Nossif, BK Schaffer, E Tsai, MI Papisov and TJ Brady
Department of Radiology, Massachusetts General Hospital, Charlestown 02129.

The authors developed and evaluated a polymer as a contrast agent for magnetic resonance (MR) angiography. The agent consists of a monomethoxy ether of poly(ethylene glycol) covalently attached to poly(L-lysine) (PL), with PL serving as the carrier of gadolinium diethylenetriaminepentaacetic acid (DTPA). Immunogenicity and toxicity studies were performed in mice, and biokinetic and metabolic studies were performed in rats. Dose response studies were performed with a three-dimensional time-of-flight sequence in eight rats. No permanent immune response was elicited against Gd-DTPA or the carrier molecule, and accumulation in organs of the reiculoendothelial system was minimal. The blood half-life of the agent was 14 hours. A dose of 20 mumol of gadolinium per kilogram of body weight was sufficient to increase the vessel-muscle ratio by four- to fivefold. Contrast was substantially improved and remained unchanged 2 hours after contrast medium administration, and good visualization of four orders of vasculature was allowed.


This article has been cited by other articles:


Home page
DiabetesHome page
Z. Medarova, G. Castillo, G. Dai, E. Bolotin, A. Bogdanov, and A. Moore
Noninvasive Magnetic Resonance Imaging of Microvascular Changes in Type 1 Diabetes
Diabetes, November 1, 2007; 56(11): 2677 - 2682.
[Abstract] [Full Text] [PDF]


Home page
Cancer Res.Home page
Y. R. Kim, A. Yudina, J. Figueiredo, W. Reichardt, D. Hu-Lowe, A. Petrovsky, H. W. Kang, D. Torres, U. Mahmood, R. Weissleder, et al.
Detection of Early Antiangiogenic Effects in Human Colon Adenocarcinoma Xenografts: In vivo Changes of Tumor Blood Volume in Response to Experimental VEGFR Tyrosine Kinase Inhibitor
Cancer Res., October 15, 2005; 65(20): 9253 - 9260.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
M. Seshadri, J. A. Spernyak, R. Mazurchuk, S. H. Camacho, A. R. Oseroff, R. T. Cheney, and D. A. Bellnier
Tumor Vascular Response to Photodynamic Therapy and the Antivascular Agent 5,6-Dimethylxanthenone-4-Acetic Acid: Implications for Combination Therapy
Clin. Cancer Res., June 1, 2005; 11(11): 4241 - 4250.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Reimer, C. Bremer, T. Allkemper, M. Engelhardt, M. Mahler, W. Ebert, and B. Tombach
Myocardial Perfusion and MR Angiography of Chest with SH U 555 C: Results of Placebo-controlled Clinical Phase I Study
Radiology, May 1, 2004; 231(2): 474 - 481.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Weissleder and U. Mahmood
Molecular Imaging
Radiology, May 1, 2001; 219(2): 316 - 333.
[Abstract] [Full Text]


Home page
RadiologyHome page
F. Sardanelli, G. Molinari, F. Zandrino, and M. Balbi
Three-dimensional, Navigator-Echo MR Coronary Angiography in Detecting Stenoses of the Major Epicardial Vessels, with Conventional Coronary Angiography as the Standard of Reference
Radiology, March 1, 2000; 214(3): 808 - 814.
[Abstract] [Full Text]


Home page
RadiologyHome page
U. Mahmood, C.-H. Tung, A. Bogdanov Jr, and R. Weissleder
Near-Infrared Optical Imaging of Protease Activity for Tumor Detection
Radiology, December 1, 1999; 213(3): 866 - 870.
[Abstract] [Full Text]


Home page
RadiologyHome page
T. Allkemper, C. Bremer, L. Matuszewski, W. Ebert, and P. Reimer
Contrast-enhanced Blood-Pool MR Angiography with Optimized Iron Oxides: Effect of Size and Dose on Vascular Contrast Enhancement in Rabbits
Radiology, May 1, 2002; 223(2): 432 - 438.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.