Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Edelman, R. R.
Right arrow Articles by Li, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Edelman, R. R.
Right arrow Articles by Li, W.

Radiology, Vol 187, 719-722, Copyright © 1993 by Radiological Society of North America


ARTICLES

Human coronary arteries: projection angiograms reconstructed from breath-hold two-dimensional MR images

RR Edelman, WJ Manning, J Pearlman and W Li
Department of Radiology, Charles A. Dana Research Institute, Boston, Mass 02215.

The authors sought to render projection magnetic resonance (MR) angiograms depicting a substantial length of human coronary arteries from sequential breath-hold two-dimensional MR images. Tomographic images of the right and left anterior descending coronary arteries were collected with use of a segmented gradient-recalled sequence that incorporated fat suppression and prone positioning of the patient over a surface coil. After editing the images to eliminate overlapping chamber signals and after realigning the images, a maximum-intensity- projection algorithm was applied to create projection angiograms. For the 10 coronary arteries without severe narrowing, visualized length with projection MR angiography was 109 mm +/- 29 (mean +/- standard error of estimate) versus 121 mm +/- 29 with conventional coronary angiography (ranges, 62-147 mm and 70-180 mm, respectively). At conventional angiography linear regression indicated vessel length to be 1.03 times the length depicted at MR angiography with good correlation (r = .8). Results indicate good correlation between measurements of vessel length with both conventional and MR angiography.


This article has been cited by other articles:


Home page
RadiologyHome page
F. Sardanelli, G. Molinari, F. Zandrino, and M. Balbi
Three-dimensional, Navigator-Echo MR Coronary Angiography in Detecting Stenoses of the Major Epicardial Vessels, with Conventional Coronary Angiography as the Standard of Reference
Radiology, March 1, 2000; 214(3): 808 - 814.
[Abstract] [Full Text]


Home page
J Am Coll CardiolHome page
J. H. S. Cullen, M. A. Horsfield, C. R. Reek, G. R. Cherryman, D. B. Barnett, and N. J. Samani
A myocardial perfusion reserve index in humans using first-pass contrast-enhanced magnetic resonance imaging
J. Am. Coll. Cardiol., April 1, 1999; 33(5): 1386 - 1394.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.