Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Niklason, L. T.
Right arrow Articles by Chan, H. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Niklason, L. T.
Right arrow Articles by Chan, H. P.

Radiology, Vol 187, 729-733, Copyright © 1993 by Radiological Society of North America


ARTICLES

Interventional radiologists: occupational radiation doses and risks

LT Niklason, MV Marx and HP Chan
Department of Radiology, Massachusetts General Hospital, Boston 02114.

Interventional radiologists receive nonuniform occupational radiation doses, with relatively high doses to the head and extremities and low doses to the trunk, which is protected by a lead apron. Twenty-eight interventional radiologists from 17 institutions wore thermoluminescent dosimeters over their collars and under their aprons for a 2-month period. The estimated annual radiation dose was converted to effective dose as suggested by the International Commission on Radiological Protection. Effective dose is used to relate the risk associated with nonuniform dose to that associated with an equivalent uniform whole- body dose. The mean annual effective dose was 3.16 mSv (316 mrem), with a range of 0.37-10.1 mSv. The mean annual effective dose is approximately equal to the mean natural background dose of 3 mSv per year from radon and other natural sources and is only 6% of the National Council on Radiation Protection and Measurements' recommended effective dose equivalent limit of 50 mSv per year. The annual radiation risk of fatal cancer would be less than one per 10,000 for almost the entire career of an interventional radiologist.


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
H. Jarvinen, N. Buls, P. Clerinx, J. Jansen, S. Miljanic, D. Nikodemova, M. Ranogajec-Komor, and F. d'Errico
OVERVIEW OF DOUBLE DOSIMETRY PROCEDURES FOR THE DETERMINATION OF THE EFFECTIVE DOSE TO THE INTERVENTIONAL RADIOLOGY STAFF
Radiat Prot Dosimetry, May 14, 2008; (2008) ncn082v1.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
T Siiskonen, M Tapiovaara, A Kosunen, M Lehtinen, and E Vartiainen
Monte Carlo simulations of occupational radiation doses in interventional radiology
Br. J. Radiol., June 1, 2007; 80(954): 460 - 468.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
B. A. Schueler, T. J. Vrieze, H. Bjarnason, and A. W. Stanson
An Investigation of Operator Exposure in Interventional Radiology
RadioGraphics, September 1, 2006; 26(5): 1533 - 1541.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Vano, L. Gonzalez, J. M. Fernandez, C. Prieto, and E. Guibelalde
Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology
Radiat Prot Dosimetry, June 1, 2006; 118(3): 325 - 330.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N Hidajat, P Wust, M Kreuschner, R Felix, and R-J Schroder
Radiation risks for the radiologist performing transjugular intrahepatic portosystemic shunt (TIPS).
Br. J. Radiol., June 1, 2006; 79(942): 483 - 486.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
H. Goni, D. Papadopoulou, Em. Yakoumakis, N. Stratigis, J. Benos, V. Siriopoulou, Tr. Makri, and Ev. Georgiou
Investigation of occupational radiation exposure during interventional cardiac catheterisations performed via radial artery
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 107 - 110.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
E Vano
Radiation exposure to cardiologists: how it could be reduced
Heart, October 1, 2003; 89(10): 1123 - 1124.
[Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J M C Gallet and M H Reed
Paediatric personnel extremity dose study
Br. J. Radiol., March 1, 2002; 75(891): 249 - 252.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. N. King, A. M. Champlin, C. A. Kelsey, and D. A. Tripp
Using a Sterile Disposable Protective Surgical Drape for Reduction of Radiation Exposure to Interventionalists
Am. J. Roentgenol., January 1, 2002; 178(1): 153 - 157.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
W M Teeuwisse, J Geleijns, J J Broerse, W R Obermann, and E L van Persijn van Meerten
Patient and staff dose during CT guided biopsy, drainage and coagulation
Br. J. Radiol., August 1, 2001; 74(884): 720 - 726.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.