Radiology, Vol 187, 729-733, Copyright © 1993 by Radiological Society of North America
ARTICLES |
LT Niklason, MV Marx and HP Chan
Department of Radiology, Massachusetts General Hospital, Boston 02114.
Interventional radiologists receive nonuniform occupational radiation doses, with relatively high doses to the head and extremities and low doses to the trunk, which is protected by a lead apron. Twenty-eight interventional radiologists from 17 institutions wore thermoluminescent dosimeters over their collars and under their aprons for a 2-month period. The estimated annual radiation dose was converted to effective dose as suggested by the International Commission on Radiological Protection. Effective dose is used to relate the risk associated with nonuniform dose to that associated with an equivalent uniform whole- body dose. The mean annual effective dose was 3.16 mSv (316 mrem), with a range of 0.37-10.1 mSv. The mean annual effective dose is approximately equal to the mean natural background dose of 3 mSv per year from radon and other natural sources and is only 6% of the National Council on Radiation Protection and Measurements' recommended effective dose equivalent limit of 50 mSv per year. The annual radiation risk of fatal cancer would be less than one per 10,000 for almost the entire career of an interventional radiologist.
This article has been cited by other articles:
![]() |
H. Jarvinen, N. Buls, P. Clerinx, J. Jansen, S. Miljanic, D. Nikodemova, M. Ranogajec-Komor, and F. d'Errico OVERVIEW OF DOUBLE DOSIMETRY PROCEDURES FOR THE DETERMINATION OF THE EFFECTIVE DOSE TO THE INTERVENTIONAL RADIOLOGY STAFF Radiat Prot Dosimetry, May 14, 2008; (2008) ncn082v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
T Siiskonen, M Tapiovaara, A Kosunen, M Lehtinen, and E Vartiainen Monte Carlo simulations of occupational radiation doses in interventional radiology Br. J. Radiol., June 1, 2007; 80(954): 460 - 468. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. A. Schueler, T. J. Vrieze, H. Bjarnason, and A. W. Stanson An Investigation of Operator Exposure in Interventional Radiology RadioGraphics, September 1, 2006; 26(5): 1533 - 1541. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Vano, L. Gonzalez, J. M. Fernandez, C. Prieto, and E. Guibelalde Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology Radiat Prot Dosimetry, June 1, 2006; 118(3): 325 - 330. [Abstract] [Full Text] [PDF] |
||||
![]() |
N Hidajat, P Wust, M Kreuschner, R Felix, and R-J Schroder Radiation risks for the radiologist performing transjugular intrahepatic portosystemic shunt (TIPS). Br. J. Radiol., June 1, 2006; 79(942): 483 - 486. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Goni, D. Papadopoulou, Em. Yakoumakis, N. Stratigis, J. Benos, V. Siriopoulou, Tr. Makri, and Ev. Georgiou Investigation of occupational radiation exposure during interventional cardiac catheterisations performed via radial artery Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 107 - 110. [Abstract] [Full Text] [PDF] |
||||
![]() |
E Vano Radiation exposure to cardiologists: how it could be reduced Heart, October 1, 2003; 89(10): 1123 - 1124. [Full Text] [PDF] |
||||
![]() |
J M C Gallet and M H Reed Paediatric personnel extremity dose study Br. J. Radiol., March 1, 2002; 75(891): 249 - 252. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. N. King, A. M. Champlin, C. A. Kelsey, and D. A. Tripp Using a Sterile Disposable Protective Surgical Drape for Reduction of Radiation Exposure to Interventionalists Am. J. Roentgenol., January 1, 2002; 178(1): 153 - 157. [Abstract] [Full Text] [PDF] |
||||
![]() |
W M Teeuwisse, J Geleijns, J J Broerse, W R Obermann, and E L van Persijn van Meerten Patient and staff dose during CT guided biopsy, drainage and coagulation Br. J. Radiol., August 1, 2001; 74(884): 720 - 726. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |