Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schmitz-Rode, T.
Right arrow Articles by Rosch, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schmitz-Rode, T.
Right arrow Articles by Rosch, J.

Radiology, Vol 188, 95-100, Copyright © 1993 by Radiological Society of North America


ARTICLES

Self-expandable spindle for transcatheter vascular occlusion: in vivo experiments. Work in progress

T Schmitz-Rode, H Timmermans, B Uchida, K Kichikawa, N Nishida, RW Gunther and J Rosch
Department of Diagnostic Radiology, University of Technology Aachen, Germany.

A mechanical vascular occluder was studied in eight pigs to test its efficacy in arteries of different diameters, stability over time, and safety in placement. The main component is a self-expandable spindle made of tubular stainless steel mesh. Simple steel spindles, double spindles, and Dacron-core spindles were placed in the common carotid artery, main renal artery, renal artery branches, and infrarenal aorta. Follow-up arteriograms were obtained immediately, 30-60 minutes, and (except for aortic spindles) 7 days after deployment. The left common carotid artery was occluded in all pigs, regardless of spindle type. In the main renal artery and its branches, simple steel spindles did not achieve complete occlusion. Double and Dacron-core spindles produced immediate occlusion without recanalization on the 1-week follow-up arteriogram, except for one spindle with an incomplete Dacron core and two spindles that did not completely fill the arterial lumen. Two Dacron-core spindles achieved immediate complete occlusion of the infrarenal aorta. No migration was seen with any spindle.