Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sakuma, H.
Right arrow Articles by Higgins, C. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sakuma, H.
Right arrow Articles by Higgins, C. B.

Radiology, Vol 188, 377-380, Copyright © 1993 by Radiological Society of North America


ARTICLES

Evaluation of left ventricular volume and mass with breath-hold cine MR imaging

H Sakuma, N Fujita, TK Foo, GR Caputo, SJ Nelson, J Hartiala, A Shimakawa and CB Higgins
Department of Radiology, University of California, San Francisco 94143- 0628.

Left ventricular (LV) volumes and mass were evaluated in 10 healthy volunteers with breath-hold cine magnetic resonance (MR) imaging. The results were compared with those obtained with conventional cine MR imaging. The breath-hold studies showed no ghosting artifact, and cardiac edges were clearly identified because of the reduced blurring. Measurements of LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), and LV mass obtained with breath-hold cine MR imaging showed close correlation with those obtained with conventional cine MR imaging (r = .98, .97, and .99, respectively). The interobserver variabilities for LVEDV, LVESV, and LV mass determined with breath-hold cine MR imaging (4.0%, 8.0%, and 3.7%, respectively) were equal to or less than those determined with conventional cine MR imaging (4.0%, 8.6%, and 5.0%, respectively). The authors conclude that breath-hold cine MR imaging is highly useful because an accurate assessment of cardiac function is obtained in less than 5 minutes.


This article has been cited by other articles:


Home page
RadiologyHome page
H. V. Dinh, J. Alvergue, J. Sayre, J. S. Child, V. S. Deshpande, G. Laub, and J. P. Finn
Isovolumic Cardiac Contraction on High-Temporal-Resolution Cine MR Images: Study in Heart Failure Patients and Healthy Volunteers
Radiology, August 1, 2008; 248(2): 458 - 465.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
F. Saremi, J. D. Grizzard, and R. J. Kim
Optimizing Cardiac MR Imaging: Practical Remedies for Artifacts
RadioGraphics, July 1, 2008; 28(4): 1161 - 1187.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
S.-C. Yap, R.-J. M. van Geuns, A. Nemes, F. J. Meijboom, J. S. McGhie, M. L. Geleijnse, M. L. Simoons, and J. W. Roos-Hesselink
Rapid and accurate measurement of LV mass by biplane real-time 3D echocardiography in patients with concentric LV hypertrophy: comparison to CMR
Eur J Echocardiogr, March 1, 2008; 9(2): 255 - 260.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. B. Mascarenhas, R. Muthupillai, B. Cheong, M. Pereyra, and S. D. Flamm
Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold.
Am. J. Roentgenol., November 1, 2006; 187(5): 1235 - 1239.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. T. Boll, A. S. Bossert, A. J. Aschoff, M. H. Hoffmann, and R. C. Gilkeson
Synergy of MDCT and Cine MRI for the Evaluation of Cardiac Motility
Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S379 - S386.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Sipola, K. Lauerma, P. Jaaskelainen, M. Laakso, K. Peuhkurinen, H. Manninen, H. J. Aronen, and J. Kuusisto
Cine MR Imaging of Myocardial Contractile Impairment in Patients with Hypertrophic Cardiomyopathy Attributable to Asp175Asn Mutation in the {alpha}-Tropomyosin Gene
Radiology, September 1, 2005; 236(3): 815 - 824.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Lembcke, A. C. Borges, S. Dushe, P. M. Dohmen, T. H. Wiese, P. Rogalla, K.-G. A. Hermann, B. Hamm, and C. N. H. Enzweiler
Assessment of Mitral Valve Regurgitation at Electron-Beam CT: Comparison with Doppler Echocardiography
Radiology, July 1, 2005; 236(1): 47 - 55.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Schlosser, K. Pagonidis, C. U. Herborn, P. Hunold, K.-U. Waltering, T. C. Lauenstein, and J. Barkhausen
Assessment of Left Ventricular Parameters Using 16-MDCT and New Software for Endocardial and Epicardial Border Delineation
Am. J. Roentgenol., March 1, 2005; 184(3): 765 - 773.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Spuentrup, J. Schroeder, A. H. Mahnken, T. Schaeffter, R. M. Botnar, H. P. Kuhl, P. Hanrath, R. W. Gunther, and A. Buecker
Quantitative Assessment of Left Ventricular Function with Interactive Real-Time Spiral and Radial MR Imaging
Radiology, June 1, 2003; 227(3): 870 - 876.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Plein, S. Bulugahapitiya, T. R. Jones, G. J. Bainbridge, J. P. Ridgway, and M. U. Sivananthan
Cardiac MR Imaging with External Respirator: Synchronizing Cardiac and Respiratory Motion—Feasibility Study
Radiology, June 1, 2003; 227(3): 877 - 882.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Sipola, K. Lauerma, M. Husso-Saastamoinen, J. T. Kuikka, E. Vanninen, T. Laitinen, H. Manninen, P. Niemi, K. Peuhkurinen, P. Jaaskelainen, et al.
First-Pass MR Imaging in the Assessment of Perfusion Impairment in Patients with Hypertrophic Cardiomyopathy and the Asp175Asn Mutation of the {alpha}-Tropomyosin Gene
Radiology, January 1, 2003; 226(1): 129 - 137.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Schalla, C. Klein, I. Paetsch, H. Lehmkuhl, A. Bornstedt, B. Schnackenburg, E. Fleck, and E. Nagel
Real-Time MR Image Acquisition during High-Dose Dobutamine Hydrochloride Stress for Detecting Left Ventricular Wall-Motion Abnormalities in Patients with Coronary Arterial Disease
Radiology, September 1, 2002; 224(3): 845 - 851.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. P. A. Ioannidis, T. A. Trikalinos, and P. G. Danias
Electrocardiogram-gated single-photonemission computed tomography versus cardiacmagnetic resonance imaging for the assessmentof left ventricular volumes and ejection fraction: A meta-analysis
J. Am. Coll. Cardiol., June 19, 2002; 39(12): 2059 - 2068.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. C. C. Moon, C. H. Lorenz, J. M. Francis, G. C. Smith, and D. J. Pennell
Breath-hold FLASH and FISP Cardiovascular MR Imaging: Left Ventricular Volume Differences and Reproducibility
Radiology, June 1, 2002; 223(3): 789 - 797.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. J. Salton, M. L. Chuang, C. J. O'Donnell, M. J. Kupka, M. G. Larson, K. V. Kissinger, R. R. Edelman, D. Levy, and W. J. Manning
Gender differences and normal left ventricular anatomy in an adult population free of hypertension: A cardiovascular magnetic resonance study of the Framingham Heart Study Offspring cohort
J. Am. Coll. Cardiol., March 20, 2002; 39(6): 1055 - 1060.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. W. Koskenvuo, J. J. Hartiala, J. Knuuti, H. Sakuma, J. O. Toikka, M. Komu, M. Saraste, and P. Niemi
Assessing Coronary Sinus Blood Flow in Patients with Coronary Artery Disease: A Comparison of Phase-Contrast MR Imaging with Positron Emission Tomography
Am. J. Roentgenol., November 1, 2001; 177(5): 1161 - 1166.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Kaji, P. C. Yang, A. B. Kerr, W. H. W. Tang, C. H. Meyer, A. Macovski, J. M. Pauly, D. G. Nishimura, and B. S. Hu
Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system
J. Am. Coll. Cardiol., August 1, 2001; 38(2): 527 - 533.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. L. Chuang, M. G. Hibberd, C. J. Salton, R. A. Beaudin, M. F. Riley, R. A. Parker, P. S. Douglas, and W. J. Manning
Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction: Assessment by two- and three-dimensional echocardiography and magnetic resonance imaging
J. Am. Coll. Cardiol., February 1, 2000; 35(2): 477 - 484.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Cottin, C. Touzery, F. Guy, A. Lalande, O. Ressencourt, S. Roy, P. M. Walker, P. Louis, F. Brunotte, and J. E. Wolf
MR Imaging of the Heart in Patients after Myocardial Infarction: Effect of Increasing Intersection Gap on Measurements of Left Ventricular Volume, Ejection Fraction, and Wall Thickness
Radiology, November 1, 1999; 213(2): 513 - 520.
[Abstract] [Full Text]


Home page
J Am Coll CardiolHome page
E. Tadamura, T. Kudoh, M. Motooka, M. Inubushi, S. Shirakawa, N. Hattori, T. Okada, T. Matsuda, T. Koshiji, K. Nishimura, et al.
Assessment of regional and global left ventricular function by reinjection Tl-201 and rest Tc-99m sestamibi ECG-gated SPECT: Comparison with three-dimensional magnetic resonance imaging
J. Am. Coll. Cardiol., March 15, 1999; 33(4): 991 - 997.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. Gepstein, G. Hayam, S. Shpun, and S. A. Ben-Haim
Hemodynamic Evaluation of the Heart With a Nonfluoroscopic Electromechanical Mapping Technique
Circulation, November 18, 1997; 96(10): 3672 - 3680.
[Abstract] [Full Text]


Home page
CirculationHome page
E. E. van der Wall, H. W. Vliegen, A. de Roos, and A. V.G. Bruschke
Magnetic Resonance Imaging in Coronary Artery Disease
Circulation, November 1, 1995; 92(9): 2723 - 2739.
[Abstract] [Full Text]


Home page
RadiologyHome page
V. S. Lee, D. Resnick, J. M. Bundy, O. P. Simonetti, P. Lee, and J. C. Weinreb
Cardiac Function: MR Evaluation in One Breath Hold with Real-time True Fast Imaging with Steady-State Precession
Radiology, March 1, 2002; 222(3): 835 - 842.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.