Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chambers, T. P.
Right arrow Articles by Confer, S. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chambers, T. P.
Right arrow Articles by Confer, S. R.

Radiology, Vol 188, 627-631, Copyright © 1993 by Radiological Society of North America


ARTICLES

Hepatic CT enhancement: a method to demonstrate reproducibility

TP Chambers, RL Baron, RM Lush, GD Dodd 3d, WJ Miller and SR Confer
Department of Radiology, University of Pittsburgh Medical Center, Pa.

Optimal techniques for intravenous administration of contrast material in computed tomographic (CT) examination of the liver remain controversial mainly because of inaccurate methods of data evaluation. This study tested the reproducibility of hepatic contrast material enhancement within the same patient and the accuracy of two methods of data analysis. Fourteen patients received identical CT examinations. Attenuation of liver and vessels was measured before and after administration of contrast material, and enhancement was calculated for each image. Data were analyzed by averaging enhancement values obtained over 5- and 10-second intervals and by using a new computer program that creates an enhancement-time curve and measures area under the curve (AUC) for any specific time interval. Data were compared between patients' first and second examinations. Mean liver enhancement was nearly identical at all time intervals with the AUC technique. Analysis of interpatient data showed marked variability of all parameters at all measured time intervals, suggesting that results from comparative studies within the same patient may be more accurate than those for studies of two different treatment groups. The AUC technique is preferable to other methods of data analysis for contrast enhancement evaluation.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. F. Behrendt, A. H. Mahnken, S. Stanzel, P. Seidensticker, E. Jost, R. W. Gunther, and G. Muhlenbruch
Intraindividual Comparison of Contrast Media Concentrations for Combined Abdominal and Thoracic MDCT
Am. J. Roentgenol., July 1, 2008; 191(1): 145 - 150.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. T. Bae, K. Awai, and Y. Yamashita
Comparison of Moderate versus High Concentration of Contrast Media Injected at the Same Total Iodine Dose and Fixed Injection Duration * Drs Awai and Yamashita respond:
Radiology, August 1, 2005; 236(2): 740 - 741.
[Full Text] [PDF]