Radiology, Vol 189, 647-656, Copyright © 1993 by Radiological Society of North America
REVIEWS |
JP Heiken, JA Brink and MW Vannier
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO 63110.
Spiral (helical) computed tomography (CT) involves continuous patient translation during x-ray source rotation and data acquisition. As a result, a volume data set is obtained in a relatively short period of time. For chest or abdominal scanning, an entire examination can be completed in a single breath hold of the patient or in several successive short breath holds. The data volume may be viewed as conventional transaxial images or with multiplanar and three- dimensional methods. The authors review the technologic aspects of spiral CT, as well as its advantages, limitations, and current clinical applications.
This article has been cited by other articles:
![]() |
A. Gosalia, L. B. Haramati, M. P. Sheth, and H. Spindola-Franco CT Detection of Acute Myocardial Infarction Am. J. Roentgenol., June 1, 2004; 182(6): 1563 - 1566. [Abstract] [Full Text] [PDF] |
||||
![]() |
C Walter, M Kruessell, A Gindele, H G Brochhagen, A Gossmann, and P Landwehr Imaging of renal lesions: evaluation of fast MRI and helical CT Br. J. Radiol., October 1, 2003; 76(910): 696 - 703. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Awai, K. Takada, H. Onishi, and S. Hori Aortic and Hepatic Enhancement and Tumor-to-Liver Contrast: Analysis of the Effect of Different Concentrations of Contrast Material at Multi-Detector Row Helical CT Radiology, September 1, 2002; 224(3): 757 - 763. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. K. Kang, Y. Y. Jeong, J. H. Choi, S. Choi, T. W. Chung, J. J. Seo, J. K. Kim, W. Yoon, and J. G. Park Three-dimensional Multi-Detector Row CT Portal Venography in the Evaluation of Portosystemic Collateral Vessels in Liver Cirrhosis RadioGraphics, September 1, 2002; 22(5): 1053 - 1061. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Lim, D. Choi, S. H. Kim, S. J. Lee, W. J. Lee, H. K. Lim, and S. Kim Detection of Hepatocellular Carcinoma: Value of Adding Delayed Phase Imaging to Dual-Phase Helical CT Am. J. Roentgenol., July 1, 2002; 179(1): 67 - 73. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kim, T. Murakami, M. Hori, M. Takamura, S. Takahashi, A. Okada, S. Kawata, M. Cruz, M. P. Federle, and H. Nakamura Small Hypervascular Hepatocellular Carcinoma Revealed by Double Arterial Phase CT Performed with Single Breath-Hold Scanning and Automatic Bolus Tracking Am. J. Roentgenol., April 1, 2002; 178(4): 899 - 904. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Uematsu, M. Sano, and K. Homma In Vitro High-Resolution Helical CT of Small Axillary Lymph Nodes in Patients with Breast Cancer: Correlation of CT and Histology Am. J. Roentgenol., April 1, 2001; 176(4): 1069 - 1074. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Mitsumori, K. Yasui, S. Akaki, I. Togami, I. Joja, H. Hashimoto, H. Kumon, and Y. Hiraki Evaluation of Crossing Vessels in Patients with Ureteropelvic Junction Obstruction by Means of Helical CT RadioGraphics, September 1, 2000; 20(5): 1383 - 1393. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. W. Steyerberg, H. J. Keizer, D. T. Sleijfer, S. D. Fosså, D. F. Bajorin, A. Gerl, R. de Wit, W. J. Kirkels, H. S. Koops, and J. D. F. Habbema Retroperitoneal Metastases in Testicular Cancer: Role of CT Measurements of Residual Masses in Decision Making for Resection after Chemotherapy Radiology, May 1, 2000; 215(2): 437 - 444. [Abstract] [Full Text] |
||||
![]() |
B. A. Urban and E. K. Fishman Tailored Helical CT Evaluation of Acute Abdomen : (CME available in print version and on RSNA Link) RadioGraphics, May 1, 2000; 20(3): 725 - 749. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Azhari and D. Sazbon Volumetric Imaging with Ultrasonic Spiral CT Radiology, July 1, 1999; 212(1): 270 - 275. [Abstract] [Full Text] |
||||
![]() |
B. A. Birnbaum, J. E. Jacobs, C. P. Langlotz, and P. Ramchandani Assessment of a Bolus-tracking Technique in Helical Renal CT to Optimize Nephrographic Phase Imaging Radiology, April 1, 1999; 211(1): 87 - 94. [Abstract] [Full Text] |
||||
![]() |
R. Corti, C. Ferrari, M. Roberti, M. Alerci, P. L. Pedrazzi, and A. Gallino Spiral Computed Tomography : A Novel Diagnostic Approach for Investigation of the Extracranial Cerebral Arteries and Its Complementary Role in Duplex Ultrasonography Circulation, September 8, 1998; 98(10): 984 - 989. [Abstract] [Full Text] |
||||
![]() |
J. Gorich, A.J. Aschoff, K.-H. Orend, V. Mickley, R. Sokiranski, H.-J. Brambs, N. Rilinger, and S. C. Kramer Diagnostic Value of Spiral-CT Angiography in Comparison with Digital Subtraction Angiography Before and After Peripheral Vascular Intervention Angiology, August 1, 1998; 49(8): 599 - 606. [Abstract] [PDF] |
||||
![]() |
J Davies, A G Chalmers, H M Sue-Ling, J May, G V Miller, I G Martin, and D Johnston Spiral computed tomography and operative staging of gastric carcinoma: a comparison with histopathological staging Gut, September 1, 1997; 41(3): 314 - 319. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |