Radiology, Vol 189, 765-768, Copyright © 1993 by Radiological Society of North America
ARTICLES |
TH Lim, DH Lee, YH Kim, SW Park, PH Park, DM Seo, ST Kim, TK Lee and CW Mun
Department of Radiology, Asan Medical Center, SongPa-Ku, Seoul, Korea.
PURPOSE: To assess the capability of gadolinium polylysine-enhanced cardiac magnetic resonance (MR) imaging in depicting normal and ischemic myocardium during occlusion and reperfusion of the left anterior descending artery. MATERIALS AND METHODS: Contrast-enhanced MR images were obtained in 18 cats during 90 minutes each of occlusion and reperfusion. The change in signal intensity (SI) was compared among normal myocardium and central and peripheral ischemic zones. Results were compared with those of 2,3,5-triphenyltetrazolium chloride staining. RESULTS: During occlusion, the ischemic zone lacked enhancement while normal myocardium had gradual enhancement. During reperfusion, the ischemic zone had strong enhancement. In cats with large infarction, the central and peripheral ischemic zones had intermediate and high SI, respectively; in cats with focal or no infarction, the entire ischemic zone had high SI. CONCLUSION: Occlusive and reperfused myocardial infarction can be detected at gadolinium polylysine-enhanced MR imaging by means of differential SI changes in normal myocardium and central and peripheral ischemic zones.
This article has been cited by other articles:
![]() |
S. S. Lee, H. W. Goo, S. B. Park, C. H. Lim, G. Gong, J. B. Seo, and T.-H. Lim MR Imaging of Reperfused Myocardial Infarction: Comparison of Necrosis-Specific and Intravascular Contrast Agents in a Cat Model Radiology, March 1, 2003; 226(3): 739 - 747. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Choi, S. S. Lee, S. I. Choi, S. T. Kim, K. H. Lim, C. H. Lim, H.-J. Weinmann, and T.-H. Lim Occlusive Myocardial Infarction: Investigation of Bis-Gadolinium Mesoporphyrins-enhanced T1-weighted MR Imaging in a Cat Model Radiology, August 1, 2001; 220(2): 436 - 440. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. I. Choi, S. H. Choi, S. T. Kim, K. H. Lim, C. H. Lim, G. Y. Gong, H. Y. Kim, H.-J. Weinmann, and T.-H. Lim Irreversibly Damaged Myocardium at MR Imaging with a Necrotic Tissue-Specific Contrast Agent in a Cat Model Radiology, June 1, 2000; 215(3): 863 - 868. [Abstract] [Full Text] |
||||
![]() |
J. Bremerich, M. F. Wendland, H.a. Arheden, R. Wyttenbach, D. W. Gao, J. P. Huberty, M. W. Dae, C. B. Higgins, and M. Saeed Microvascular injury in reperfused infarcted myocardium: noninvasive assessment with contrast-enhanced echoplanar magnetic resonance imaging J. Am. Coll. Cardiol., September 1, 1998; 32(3): 787 - 793. [Abstract] [Full Text] [PDF] |
||||