Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Coleman, C. C.
Right arrow Articles by Amplatz, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Coleman, C. C.
Right arrow Articles by Amplatz, K.

Radiology, Vol 189, 803-805, Copyright © 1993 by Radiological Society of North America


ARTICLES

Mechanical thrombectomy: results of early experience

CC Coleman, C Krenzel, CA Dietz, GK Nazarian and K Amplatz
Department of Radiology, Veterans Affairs Medical Center, Minneapolis, Minn.

PURPOSE: To evaluate the clinical application of a mechanical thrombectomy device in occluded lower extremity arteries and bypass grafts. MATERIALS AND METHODS: A mechanical thrombectomy device was used in five patients with acutely occluded lower extremity bypass grafts (n = 2) or superficial femoral arteries (n = 3). RESULTS: The thrombus was completely removed in three cases (two bypass grafts and one native superficial femoral artery). In two of the patients with occlusions in the native superficial femoral artery, the thrombus was partially removed. In these two patients, the aspirate demonstrated a more fibrous thrombus that was not easily fragmented. In one of these two patients, the coagulum was thought to be embolic from the heart. CONCLUSION: The thrombectomy device works well in recent thromboses, particularly in polytetrafluoroethylene grafts in which organization does not occur. Its efficacy in chronically occluded vessels is not certain.


This article has been cited by other articles:


Home page
RadiologyHome page
S. Müller-Hülsbeck, C. Bangard, H. Schwarzenberg, C. C. Glüer, and M. Heller
In Vitro Effectiveness Study of Three Hydrodynamic Thrombectomy Devices
Radiology, May 1, 1999; 211(2): 433 - 439.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1993 by the Radiological Society of North America.