Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Newman, J. S.
Right arrow Articles by Wahl, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Newman, J. S.
Right arrow Articles by Wahl, R. L.

Radiology, Vol 190, 111-116, Copyright © 1994 by Radiological Society of North America


ARTICLES

Imaging of lymphoma with PET with 2-[F-18]-fluoro-2-deoxy-D-glucose: correlation with CT

JS Newman, IR Francis, MS Kaminski and RL Wahl
Department of Radiology, University of Michigan Hospitals, Ann Arbor 48109-0028.

PURPOSE: To prospectively compare the accuracy of positron emission tomography (PET) with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) in imaging thoracicoabdominal lymphoma to that of computed tomography (CT). MATERIALS AND METHODS: Sixteen patients with lymphoma (11 with non-Hodgkin lymphoma [NHL] and five with Hodgkin disease) underwent FDG- PET and CT. Blinded, independent interpretations of PET and CT studies were followed by a direct comparison of the images. Measurement of tumor uptake of FDG was performed on positive PET studies. RESULTS: Fifty-four foci of abnormal uptake were detected with PET in 13 patients. Forty-nine corresponding sites of lymphadenopathy and/or masses were detected with CT. All sites of adenopathy seen at CT were detected at PET. Three patients with Hodgkin disease had negative findings at abdominal PET, CT, and subsequent staging laparotomy. FDG uptake was comparable for both the low- and intermediate-grade lymphomas. CONCLUSION: These preliminary data indicate excellent accuracy for FDG-PET imaging of thoracicoabdominal lymphoma. All grades of NHL were successfully imaged with FDG-PET. PET appears to be a useful method for imaging lymphoma.


This article has been cited by other articles:


Home page
Ann OncolHome page
M. de Wit, W. Brenner, M. Hartmann, J. Kotzerke, D. Hellwig, J. Lehmann, C. Franzius, S. Kliesch, M. Schlemmer, K. Tatsch, et al.
[18F]-FDG-PET in clinical stage I/II non-seminomatous germ cell tumours: results of the German multicentre trial
Ann. Onc., May 16, 2008; (2008) mdn170v2.
[Abstract] [Full Text] [PDF]


Home page
BloodHome page
P. Seam, M. E. Juweid, and B. D. Cheson
The role of FDG-PET scans in patients with lymphoma
Blood, November 15, 2007; 110(10): 3507 - 3516.
[Abstract] [Full Text] [PDF]


Home page
haematolHome page
P. L. Zinzani, M. Tani, R. Trisolini, S. Fanti, V. Stefoni, M. Alifano, P. Castellucci, G. Musuraca, G. Dalpiaz, L. Alinari, et al.
Histological verification of positive positron emission tomography findings in the follow-up of patients with mediastinal lymphoma
Haematologica, June 1, 2007; 92(6): 771 - 777.
[Abstract] [Full Text] [PDF]


Home page
Ann OncolHome page
K Strobel, N. Schaefer, C Renner, P Veit-Haibach, D Husarik, A. Koma, and T. Hany
Cost-effective therapy remission assessment in lymphoma patients using 2-[fluorine-18]fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography: is an end of treatment exam necessary in all patients?
Ann. Onc., April 1, 2007; 18(4): 658 - 664.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Tatsumi, C. Cohade, Y. Nakamoto, E. K. Fishman, and R. L. Wahl
Direct Comparison of FDG PET and CT Findings in Patients with Lymphoma: Initial Experience
Radiology, December 1, 2005; 237(3): 1038 - 1045.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
M. E. Juweid, G. A. Wiseman, J. M. Vose, J. M. Ritchie, Y. Menda, J. E. Wooldridge, F. M. Mottaghy, E. M. Rohren, N. M. Blumstein, A. Stolpen, et al.
Response Assessment of Aggressive Non-Hodgkin's Lymphoma by Integrated International Workshop Criteria and Fluorine-18-Fluorodeoxyglucose Positron Emission Tomography
J. Clin. Oncol., July 20, 2005; 23(21): 4652 - 4661.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. Mengiardi, H. Honegger, J. Hodler, U. G. Exner, M. D. Csherhati, and W. Bruhlmann
Primary Lymphoma of Bone: MRI and CT Characteristics During and After Successful Treatment
Am. J. Roentgenol., January 1, 2005; 184(1): 185 - 192.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. G. Schaefer, T. F. Hany, C. Taverna, B. Seifert, K. D. M. Stumpe, G. K. von Schulthess, and G. W. Goerres
Non-Hodgkin Lymphoma and Hodgkin Disease: Coregistered FDG PET and CT at Staging and Restaging--Do We Need Contrast-enhanced CT?
Radiology, September 1, 2004; 232(3): 823 - 829.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. Guay, M. Lepine, J. Verreault, and F. Benard
Prognostic Value of PET Using 18F-FDG in Hodgkin's Disease for Posttreatment Evaluation
J. Nucl. Med., August 1, 2003; 44(8): 1225 - 1231.
[Abstract] [Full Text] [PDF]


Home page
BloodHome page
R. Elstrom, L. Guan, G. Baker, K. Nakhoda, J.-A. Vergilio, H. Zhuang, S. Pitsilos, A. Bagg, L. Downs, A. Mehrotra, et al.
Utility of FDG-PET scanning in lymphoma by WHO classification
Blood, May 15, 2003; 101(10): 3875 - 3876.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Takahashi, T. Inaoka, N. Murakami, H. Hirota, K. Iwata, K. Nagasawa, T. Yamada, M. Mineta, and T. Aburano
Characterization of the Normal and Hyperplastic Thymus on Chemical-Shift MR Imaging
Am. J. Roentgenol., May 1, 2003; 180(5): 1265 - 1269.
[Abstract] [Full Text] [PDF]


Home page
Ann OncolHome page
G. Jerusalem, Y. Beguin, M. F. Fassotte, T. Belhocine, R. Hustinx, P. Rigo, and G. Fillet
Early detection of relapse by whole-body positron emission tomography in the follow-up of patients with Hodgkin's disease
Ann. Onc., January 1, 2003; 14(1): 123 - 130.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. F. Hany, H. C. Steinert, G. W. Goerres, A. Buck, and G. K. von Schulthess
PET Diagnostic Accuracy: Improvement with In-Line PET-CT System: Initial Results
Radiology, November 1, 2002; 225(2): 575 - 581.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
H. A. Nabi and J. M. Zubeldia
Clinical Applications of 18F-FDG in Oncology
J. Nucl. Med. Technol., March 1, 2002; 30(1): 3 - 9.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S. S. Gambhir, J. Czernin, J. Schwimmer, D. H. S. Silverman, R. E. Coleman, and M. E. Phelps
A Tabulated Summary of the FDG PET Literature
J. Nucl. Med., May 1, 2001; 42(90050): 1S - 93.
[Full Text] [PDF]


Home page
JNMHome page
M. Tatsumi, H. Kitayama, H. Sugahara, N. Tokita, H. Nakamura, Y. Kanakura, and T. Nishimura
Whole-Body Hybrid PET with 18F-FDG in the Staging of Non-Hodgkin's Lymphoma
J. Nucl. Med., April 1, 2001; 42(4): 601 - 608.
[Abstract] [Full Text]


Home page
JNMHome page
P. J. Lugtenburg, B. Löwenberg, R. Valkema, H.-Y. Oei, S. W. Lamberts, M. J. Eijkemans, W. L. van Putten, and E. P. Krenning
Somatostatin Receptor Scintigraphy in the Initial Staging of Low-Grade Non-Hodgkin's Lymphomas
J. Nucl. Med., February 1, 2001; 42(2): 222 - 229.
[Abstract] [Full Text]


Home page
JNMHome page
E. Sutinen, S. Jyrkkio, M. Varpula, P. Lindholm, T. Gronroos, P. Lehikoinen, M. Teras, and H. Minn
Nodal Staging of Lymphoma with Whole-Body PET: Comparison of [11C]Methionine and FDG
J. Nucl. Med., December 1, 2000; 41(12): 1980 - 1988.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Anzai, S. Minoshima, G. T. Wolf, and R. L. Wahl
Head and Neck Cancer: Detection of Recurrence with Three-dimensional Principal Components Analysis at Dynamic FDG PET
Radiology, July 1, 1999; 212(1): 285 - 290.
[Abstract] [Full Text]


Home page
ThoraxHome page
V. J Lowe and K. S Naunheim
Current role of positron emission tomography in thoracic oncology
Thorax, August 1, 1998; 53(8): 703 - 712.
[Full Text]


Home page
BloodHome page
R. Carr, S. F. Barrington, B. Madan, M. J. O'Doherty, C. A.B. Saunders, J. van der Walt, and A. R. Timothy
Detection of Lymphoma in Bone Marrow by Whole-Body Positron Emission Tomography
Blood, May 1, 1998; 91(9): 3340 - 3346.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.