Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hausegger, K. A.
Right arrow Articles by Pilger, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hausegger, K. A.
Right arrow Articles by Pilger, E.

Radiology, Vol 190, 199-202, Copyright © 1994 by Radiological Society of North America


ARTICLES

Iliac artery stent placement: clinical experience with a nitinol stent

KA Hausegger, AH Cragg, J Lammer, M Lafer, F Fluckiger, GE Klein, MH Sternthal and E Pilger
Department of Radiology, University Hospital Graz, Austria.

PURPOSE: To determine the effectiveness of a prototype nitinol stent in the iliac arteries. MATERIALS AND METHODS: Fourteen patients with arteriosclerotic lesions of the iliac arteries (nine stenoses, five occlusions) were treated percutaneously with a prototype nitinol vascular stent (Cragg stent) after unsuccessful percutaneous transluminal angioplasty. RESULTS: In 13 patients available for follow- up, the mean ankle-brachial index (ABI) increased from 0.4 +/- 0.32 (standard deviation) before the procedure to 0.81 +/- 0.27 after the procedure (P < .01). After 6, 12, and 24 months, the mean ABI was 0.97 +/- 0.2, 0.87 +/- 0.15, and 0.89 +/- 0.1, respectively. In two patients, radial stiffness of the stent was too low to completely eliminate a high-grade, calcified stenosis; long-term patency of the vessel, however, was preserved. In all other patients, stent placement achieved good vascular reconstitution. No stent occlusion or restenosis was observed. CONCLUSION: The results with the Cragg stent were similar to those with other commercially available stents. These preliminary results require confirmation with a larger series.


This article has been cited by other articles:


Home page
RadiologyHome page
R. Ahmadi, M. Schillinger, T. Maca, and E. Minar
Femoropopliteal Arteries: Immediate and Long-term Results with a Dacron-covered Stent-Graft
Radiology, March 21, 2002; (2002) 2232010971.
[Abstract] [Full Text]


Home page
Vasc MedHome page
L. A Sanchez and F. J Veith
Diagnosis and treatment of chronic lower extremity ischemia
Vascular Medicine, November 1, 1998; 3(4): 291 - 299.
[Abstract] [PDF]


Home page
PERSPECT VASC SURG ENDOVASC THERHome page
G. J. Landry and J. M. Porter
Arterial Rupture Secondary to Placement of an Iliac Artery Stent
Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 1995; 8(1): 69 - 75.
[PDF]


Home page
RadiologyHome page
R. Ahmadi, M. Schillinger, T. Maca, and E. Minar
Femoropopliteal Arteries: Immediate and Long-term Results with a Dacron-covered Stent-Graft
Radiology, May 1, 2002; 223(2): 345 - 350.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.