Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Graf, O.
Right arrow Articles by Lechner, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Graf, O.
Right arrow Articles by Lechner, G.

Radiology, Vol 190, 43-47, Copyright © 1994 by Radiological Society of North America


ARTICLES

Determination of optimal time window for liver scanning with CT during arterial portography

O Graf, WI Dock, J Lammer, S Thurnher, KL Eibenberger, R Wildling, B Niederle, EK Lang and G Lechner
Department of Radiology, University of Vienna, Austria.

PURPOSE: To determine the optimal time window for scanning the liver with computed tomography (CT) during arterial portography (CTAP). MATERIALS AND METHODS: After vasodilation and contrast medium injection into the superior mesenteric artery (80 mL at 5 mL/sec), 25 repeated scans were obtained at a single level within 83 seconds in 13 patients. Attenuation was measured on every scan, and time-attenuation curves were created. Enhancement characteristics of the portal vein, liver parenchyma, aorta, and tumors were evaluated. RESULTS: Parenchymal enhancement of more than 60 HU was achieved between 18 seconds +/- 4 (standard deviation) and 67 seconds +/- 15, and high parenchyma-to- tumor contrast of more than 50 HU occurred between 18 seconds +/- 3 and 62 seconds +/- 14. CONCLUSION: To scan the liver within such a narrow time window, a spiral CT technique is necessary. When the above injection parameters are used in CTAP, the spiral CT sequence should be started 20 seconds after the beginning of the injection.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. Loewe, M. Schindl, M. Cejna, B. Niederle, J. Lammer, and S. Thurnher
Permanent Transarterial Embolization of Neuroendocrine Metastases of the Liver Using Cyanoacrylate and Lipiodol: Assessment of Mid- and Long-Term Results
Am. J. Roentgenol., May 1, 2003; 180(5): 1379 - 1384.
[Abstract] [Full Text] [PDF]