Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gur, D.
Right arrow Articles by Rosenthal, M. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gur, D.
Right arrow Articles by Rosenthal, M. S.

Radiology, Vol 191, 119-122, Copyright © 1994 by Radiological Society of North America


ARTICLES

Sequential viewing of abdominal CT images at varying rates

D Gur, WF Good, JH Oliver, FL Thaete, RL Baron, MP Federle, WL Campbell and MS Rosenthal
Department of Radiology, University of Pittsburgh, PA 15261-0001.

PURPOSE: To evaluate radiologists' ability to detect abdominal masses during sequential viewing of series of computed tomographic (CT) scans at varying rates. MATERIALS AND METHODS: Receiver operating characteristic (ROC) analysis was used to assess the ability of five experienced radiologists to determine the presence or absence of subtle abdominal masses in 29 cases (15 positive, 14 negative) while viewing CT scans sequentially at different rates (0.5, 1, 2, 4, 7, and 21 images per second) and also at reader-selectable rates. RESULTS: Even at extremely fast viewing rates (21 images per second), radiologists performed significantly better (P < .05) than would be expected by chance alone (average area Az under the ROC curve = 0.73 vs 0.5). As the viewing rate decreased, their performance increased. The reader- selectable mode was better than any fixed-rate cine mode (average Az = 0.93). CONCLUSION: Fixed-rate sequential viewing of CT images for the primary diagnosis of subtle abdominal masses should be restricted to no more than one or two images per second, but the reader-selectable viewing mode is preferable to any fixed-rate cine mode.


This article has been cited by other articles:


Home page
RadiologyHome page
C. D. Johnson
Hard- versus Soft-Copy Interpretation
Radiology, June 1, 2003; 227(3): 629 - 630.
[Full Text] [PDF]


Home page
RadiologyHome page
M. E. J. Pijl, M. N. J. M. Wasser, E. C. Joekes, C. J. H. van de Velde, and J. L. Bloem
Metastases of Colorectal Carcinoma: Comparison of Soft- and Hard-Copy Helical CT Interpretation
Radiology, June 1, 2003; 227(3): 747 - 751.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.