Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wang, G.
Right arrow Articles by Vannier, M. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wang, G.
Right arrow Articles by Vannier, M. W.

Radiology, Vol 191, 79-83, Copyright © 1994 by Radiological Society of North America


ARTICLES

Stair-step artifacts in three-dimensional helical CT: an experimental study

G Wang and MW Vannier
Division of Radiology Research, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO 63110.

PURPOSE: Stair-step artifacts in helical computed tomography (CT) are associated with inclined surfaces in longitudinal sections. The authors investigated the origin and the characteristics of the artifacts. MATERIALS AND METHODS: A cone phantom and a skull were dry-scanned with a helical CT scanner, and images were reconstructed by using the half- scan interpolation algorithm with combinations of detector collimation (1 and 5 mm), table feed (1, 2, 5, and 10 mm), and reconstruction interval (1, 2, 5, and 10 mm). RESULTS: Stair-step artifacts were perceived in most instances. Stair-step artifacts arose from two sources: large reconstruction intervals and asymmetric helix interpolation, forming isoclosed curves and spirallike patterns in three-dimensional axial views, respectively. CONCLUSION: To eliminate the stair-step artifacts, both the collimation and the table feed should be less than the longitudinal dimension of the important feature on inclined surfaces, and the reconstruction interval should be less than the table feed. Adaptive interpolation may correct the artifacts.


This article has been cited by other articles:


Home page
Dentomaxillofac RadiolHome page
T Rodt, S. Bartling, J. Zajaczek, M. Vafa, T Kapapa, O Majdani, J. Krauss, M Zumkeller, H Matthies, H Becker, et al.
Evaluation of surface and volume rendering in 3D-CT of facial fractures.
Dentomaxillofac. Radiol., July 1, 2006; 35(4): 227 - 231.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. W. Kwan, B. L. Partik, S. E. Zinck, F. P. Chan, S. T. Kee, A. N. Leung, M. Voracek, and G. D. Rubin
Primary Interpretation of Thoracic MDCT Images Using Coronal Reformations
Am. J. Roentgenol., December 1, 2005; 185(6): 1500 - 1508.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
O. Honda, T. Johkoh, S. Yamamoto, M. Koyama, N. Tomiyama, T. Kozuka, S. Hamada, N. Mihara, H. Nakamura, and N. L. Muller
Comparison of Quality of Multiplanar Reconstructions and Direct Coronal Multidetector CT Scans of the Lung
Am. J. Roentgenol., October 1, 2002; 179(4): 875 - 879.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. Engelke, C. Schaefer-Prokop, E. Schirg, J. Freihorst, S. Grubnic, and M. Prokop
High-Resolution CT and CT Angiography of Peripheral Pulmonary Vascular Disorders
RadioGraphics, July 1, 2002; 22(4): 739 - 764.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. R. Whiting, E. G. McFarland, and J. A. Brink
Influence of Image Acquisition Parameters on CT Artifacts and Polyp Depiction in Spiral CT Colonography: In Vitro Evaluation
Radiology, October 1, 2000; 217(1): 165 - 172.
[Abstract] [Full Text]


Home page
RadiologyHome page
B. C. Vande Berg, F. E. Lecouvet, P. Poilvache, J.-E. Dubuc, B. Bedat, B. Maldague, J.-J. Rombouts, and J. Malghem
Dual-Detector Spiral CT Arthrography of the Knee: Accuracy for Detection of Meniscal Abnormalities and Unstable Meniscal Tears
Radiology, September 1, 2000; 216(3): 851 - 857.
[Abstract] [Full Text]


Home page
RadiologyHome page
D. Fleischmann, G. D. Rubin, D. S. Paik, S. Y. Yen, P. R. Hilfiker, C. F. Beaulieu, and S. Napel
Stair-Step Artifacts with Single versus Multiple Detector-Row Helical CT
Radiology, July 1, 2000; 216(1): 185 - 196.
[Abstract] [Full Text]


Home page
RadiologyHome page
B. C. Vande Berg, F. E. Lecouvet, P. Poilvache, J. Jamart, R. Materne, B. Lengele, B. Maldague, and J. Malghem
Assessment of Knee Cartilage in Cadavers with Dual-Detector Spiral CT Arthrography and MR Imaging
Radiology, February 1, 2002; 222(2): 430 - 436.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.