Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fornage, B. D.
Right arrow Articles by Singletary, S. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fornage, B. D.
Right arrow Articles by Singletary, S. E.

Radiology, Vol 191, 339-342, Copyright © 1994 by Radiological Society of North America


ARTICLES

Masses in breasts with implants: diagnosis with US-guided fine-needle aspiration biopsy

BD Fornage, N Sneige and SE Singletary
Department of Diagnostic Radiology, University of Texas M.D. Anderson Cancer Center, Houston 77030.

PURPOSE: To evaluate retrospectively the findings at ultrasound (US)- guided fine-needle aspiration biopsy (FNAB) of masses in breasts that contain a prosthesis. MATERIALS AND METHODS: Real-time US-guided FNAB was performed in 22 lesions in 17 patients with breast implants. Pneumocystography was performed in seven of eight cysts. The final diagnosis was based on either histologic findings after surgical excision or a combination of cytologic, imaging, and clinical findings. RESULTS: The lesions had a mean diameter of 15 mm +/- 9 (standard deviation). Fifteen lesions (68%) were not identified on mammograms. In all cases, FNAB was completed without complication. Pneumocystography was successful in seven of seven cysts. Cytologic diagnosis was correct in 21 of 22 lesions (95%). There was one case of inadequate specimen (5%). In 16 cases (73%), the diagnosis was established with a single pass. CONCLUSION: Real-time US allowed continuous visualization of the needle during insertion and sampling, which resulted in pinpoint accuracy and safety. US-guided FNAB is recommended for needle biopsy in breasts with implants.


This article has been cited by other articles:


Home page
RadiologyHome page
R. J. Jackman and R. L. Lamm
Stereotactic Histologic Biopsy in Breasts with Implants
Radiology, January 1, 2002; 222(1): 157 - 164.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.