Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davis, C. P.
Right arrow Articles by von Schulthess, G. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davis, C. P.
Right arrow Articles by von Schulthess, G. K.

Radiology, Vol 191, 691-696, Copyright © 1994 by Radiological Society of North America


ARTICLES

Normal heart: evaluation with echo-planar MR imaging

CP Davis, GC McKinnon, JF Debatin, D Wetter, AC Eichenberger, S Duewell and GK von Schulthess
Department of Medical Radiology, University Hospital, Zurich, Switzerland.

PURPOSE: To evaluate the appearance of the heart on spin-echo (SE) and gradient-echo (GRE) echo-planar magnetic resonance (MR) images. MATERIALS AND METHODS: Nine healthy volunteers were examined with an MR imager with transaxial echo-planar imaging (EPI) capabilities. SE EPI and GRE EPI sequences were used. Full k-space signal was obtained with readout time of 40 msec per image, and total image acquisition time was 72 and 52 msec, respectively, for SE EPI and GRE EPI. RESULTS: Delineation of cardiac structures was superior with SE EPI, reflective of significantly higher contrast between myocardial and intraluminal signal intensity (SI) (P < .001). The higher (P < .01) and more homogeneous (P < .001) intraluminal SI with GRE EPI allowed better assessment of intracardiac flow. Septal SI was significantly higher for GRE EPI (P < .01), but signal homogeneity was similar for both sequences (P > .2). CONCLUSION: Diagnostic images of the heart were obtained with both SE EPI and GRE EPI. GRE EPI is more suitable for flow studies because of the higher and more homogeneous intravascular SI.


This article has been cited by other articles:


Home page
RadioGraphicsHome page
P. J. Sparrow, J. B. Kurian, T. R. Jones, and M. U. Sivananthan
MR Imaging of Cardiac Tumors
RadioGraphics, September 1, 2005; 25(5): 1255 - 1276.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Barkhausen, M. Goyen, S. G. Ruhm, H. Eggebrecht, J. F. Debatin, and M. E. Ladd
Assessment of Ventricular Function with Single Breath-Hold Real-Time Steady-State Free Precession Cine MR Imaging
Am. J. Roentgenol., March 1, 2002; 178(3): 731 - 735.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. C. Yang, A. B. Kerr, A. C. Liu, D. H. Liang, C. Hardy, C. H. Meyer, A. Macovski, J. M. Pauly, and B. S. Hu
New real-time interactive cardiac magnetic resonance imaging system complements echocardiography
J. Am. Coll. Cardiol., December 1, 1998; 32(7): 2049 - 2056.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.