Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ginsberg, L. E.
Right arrow Articles by Moody, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ginsberg, L. E.
Right arrow Articles by Moody, D. M.

Radiology, Vol 191, 813-816, Copyright © 1994 by Radiological Society of North America


ARTICLES

Air embolus risk with glass versus plastic syringes: in vitro study and implications for neuroangiography

LE Ginsberg, DA Stump, JC King, DD Deal and DM Moody
Department of Radiology, Bowman Gray School of Medicine, Winston-Salem, NC 27157-1088.

PURPOSE: To assess syringe use among neuroangiographers and evaluate air emboli produced with glass and plastic syringes. MATERIALS AND METHODS: Questionnaires on syringes use were sent to 100 members of the American Society of Neuroradiology (ASNR). An in vitro system counted emboli during injections of contrast material and saline solution with either glass or plastic syringes. At Doppler sonography, an embolic signal was defined as the power of the reflected amplitude with auditory and visual confirmation. RESULTS: Of 62 respondents, 11.3% used glass syringes exclusively and 80.6% used plastic exclusively. Glass breakage was experienced by 72.5%, and 40% of them recalled an injury associated with such a breakage. No statistically significant difference was found between glass and plastic syringes for introduction of air emboli, though two outlying values represented larger numbers of emboli in the group with plastic syringes and contrast material. CONCLUSION: No reason for the continued use of glass syringes was found. No statistically greater risk of air emboli was shown with plastic syringes, and risk of breakage and injury is prevented. Caution is advised when injecting contrast material with plastic syringes because more air emboli may be introduced.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
C. P. Derdeyn
Diffusion-weighted Imaging as a Surrogate Marker for Stroke as a Complication of Cerebrovascular Procedures and Devices
AJNR Am. J. Neuroradiol., August 1, 2001; 22(7): 1234 - 1235.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. C. Mamourian, M. Weglarz, J. Dunn, L. D. Cromwell, and A. J. Saykin
Injection of Air Bubbles during Flushing of Angiocatheters: An In Vitro Trial of Conventional Hardware and Techniques
AJNR Am. J. Neuroradiol., April 1, 2001; 22(4): 709 - 712.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
Cooperative Study between the ASNR ASITN, and the
Quality Improvement Guidelines for Adult Diagnostic Neuroangiography
AJNR Am. J. Neuroradiol., January 1, 2000; 21(1): 146 - 150.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.