|
|
||||||||
Radiology, Vol 192, 129-139, Copyright © 1994 by Radiological Society of North America
ARTICLES |
SW Atlas, J Listerud, W Chung and ES Flamm
Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia 19104.
PURPOSE: To compare a new method for postprocessing data, soft thresholding and depth cueing of unrestricted techniques (STANDOUT), with maximum intensity projection (MIP) for magnetic resonance (MR) angiograms of intracranial aneurysms. MATERIALS AND METHODS: Eighteen patients with 19 intracranial aneurysms were studied. Images generated with STANDOUT were compared with those of MIP for both three- dimensional (3D) time-of-flight (TOF) and 3D phase-contrast (PC) techniques. Images were assessed for detection of aneurysms, scored for delineation of aneurysmal features and overall MR angiographic characteristics, and compared with catheter angiograms. RESULTS: Both postprocessing techniques demonstrated aneurysms on most TOF and PC MR angiograms. Statistically significant improvement of aneurysmal features, aneurysmal neck definition, and delineation of adjacent arterial anatomy was seen on both TOF and PC MR angiograms with STANDOUT. Feature definition was most improved for smaller aneurysms. TOF and PC MR angiograms with STANDOUT showed improved elimination of artifactual intraluminal signal loss in normal large vessels, reduced artifactual narrowing of vessel caliber, and better small vessel delineation. CONCLUSION: STANDOUT has great benefits for postprocessing of intracranial MR angiograms, regardless of the technique of data acquisition.
This article has been cited by other articles:
![]() |
J. B. Bederson, I. A. Awad, D. O. Wiebers, D. Piepgras, E. C. Haley Jr, T. Brott, G. Hademenos, D. Chyatte, R. Rosenwasser, and C. Caroselli Recommendations for the Management of Patients With Unruptured Intracranial Aneurysms : A Statement for Healthcare Professionals From the Stroke Council of the American Heart Association Stroke, November 1, 2000; 31(11): 2742 - 2750. [Full Text] [PDF] |
||||
![]() |
J. B. Bederson, I. A. Awad, D. O. Wiebers, D. Piepgras, E. C. Haley Jr, T. Brott, G. Hademenos, D. Chyatte, R. Rosenwasser, and C. Caroselli Recommendations for the Management of Patients With Unruptured Intracranial Aneurysms : A Statement for Healthcare Professionals From the Stroke Council of the American Heart Association Circulation, October 31, 2000; 102(18): 2300 - 2308. [Full Text] [PDF] |
||||
![]() |
W. M. Adams, R. D. Laitt, and A. Jackson The Role of MR Angiography in the Pretreatment Assessment of Intracranial Aneurysms: A Comparative Study AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1618 - 1628. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |