Radiology, Vol 192, 272-273, Copyright © 1994 by Radiological Society of North America
ARTICLES |
U Fischer, R Vosshenrich, D Keating, H Bruhn, W Doler, JW Oestmann and E Grabbe
Department of Radiology, Georg-August-Universitat Gottingen, Germany.
A guiding attachment is described that transforms a conventional magnetic resonance (MR) imaging surface coil into a stereotaxic biopsy unit. Eight patients, aged 38-66 years (mean, 54 years), with suspect breast lesions detected exclusively at contrast material-enhanced MR imaging underwent MR-guided needle biopsy with this unit. Diagnostic material was successfully aspirated in all patients (four carcinomas, three fibroadenomas, and one intraductal hyperplasia), and the diagnosis was subsequently confirmed at surgical biopsy. This technique promises to increase the diagnostic specificity for lesions seen solely at MR imaging.
This article has been cited by other articles:
![]() |
A. Gossmann, C. Bangard, M. Warm, R. K. Schmutzler, P. Mallmann, and K.-J. Lackner Real-time MR-guided Wire Localization of Breast Lesions by Using an Open 1.0-T Imager: Initial Experience Radiology, May 1, 2008; 247(2): 535 - 542. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Kuhl The Current Status of Breast MR Imaging * Part I. Choice of Technique, Image Interpretation, Diagnostic Accuracy, and Transfer to Clinical Practice Radiology, August 1, 2007; 244(2): 356 - 378. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Orel, M. Rosen, C. Mies, and M. D. Schnall MR Imaging-guided 9-gauge Vacuum-assisted Core-Needle Breast Biopsy: Initial Experience Radiology, December 1, 2005; 238(1): 54 - 61. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, N. Bracero, E. Morris, C. Thornton, and D. D. Dershaw MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy: Initial Clinical Experience Am. J. Roentgenol., July 1, 2005; 185(1): 183 - 193. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Lehman, E. R. DePeri, S. Peacock, M. D. McDonough, W. B. DeMartini, and J. Shook Clinical Experience with MRI-Guided Vacuum-Assisted Breast Biopsy Am. J. Roentgenol., June 1, 2005; 184(6): 1782 - 1787. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Chen, C. D. Lehman, and K. E. Dee MRI-Guided Breast Biopsy: Clinical Experience with 14-Gauge Stainless Steel Core Biopsy Needle Am. J. Roentgenol., April 1, 2004; 182(4): 1075 - 1080. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, E. A. Morris, D. D. Dershaw, C. M. Thornton, K. J. Van Zee, and L. K. Tan Fast MRI-Guided Vacuum-Assisted Breast Biopsy: Initial Experience Am. J. Roentgenol., November 1, 2003; 181(5): 1283 - 1293. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Orel and M. D. Schnall MR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer Radiology, July 1, 2001; 220(1): 13 - 30. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
U. Fischer, L. Kopka, and E. Grabbe Breast Carcinoma: Effect of Preoperative Contrast-enhanced MR Imaging on the Therapeutic Approach Radiology, December 1, 1999; 213(3): 881 - 888. [Abstract] [Full Text] |
||||