|
|
||||||||
Radiology, Vol 192, 351-357, Copyright © 1994 by Radiological Society of North America
ARTICLES |
TR McCauley, A Monib, KW Dickey, J Clemett, GH Meier, TK Egglin, RJ Gusberg, M Rosenblatt and JS Pollak
Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT 06510.
PURPOSE: To determine the accuracy and reliability of magnetic resonance (MR) angiography for identification of stenosis and patent distal vessels in patients with peripheral vascular disease. MATERIALS AND METHODS: Two-dimensional time-of-flight MR angiography and conventional arteriography were performed in 22 patients. Four blinded radiologists independently graded multiple anatomic segments. RESULTS: MR angiography allowed detection of more patent vessel segments than did conventional arteriography. For detection of significant stenosis (> 75%), MR angiography had 43%-67% sensitivity and 74%-89% specificity. Discrepancies in detection of significant stenosis occurred in 39 segments for the most accurate reviewer; 27 of these discrepancies were avoidable. CONCLUSION: For detection of significant stenosis, MR angiography has low to moderate sensitivity and specificity; however, observer variability appears to be a major contributing factor to the discrepancies. Greater reviewer experience or techniques for improving reliability may improve the accuracy of MR angiography in peripheral vascular disease.
This article has been cited by other articles:
![]() |
M. Miyazaki and V. S. Lee Nonenhanced MR Angiography Radiology, July 1, 2008; 248(1): 20 - 43. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Korosoglou, W. D. Gilson, M. Schar, A. Ustun, L. V. Hofmann, D. L. Kraitchman, and M. Stuber Hind Limb Ischemia in Rabbit Model: T2-prepared versus Time-of-Flight MR Angiography at 3 T Radiology, December 1, 2007; 245(3): 761 - 769. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Tatli, M. J. Lipton, B. D. Davison, R. B. Skorstad, and E. K. Yucel From the RSNA Refresher Courses: MR Imaging of Aortic and Peripheral Vascular Disease RadioGraphics, October 1, 2003; 23(90001): S59 - 78. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. L. Martin, K. H. Tay, B. Flak, P. D. Fry, D. L. Doyle, D. C. Taylor, Y. N. Hsiang, and L. S. Machan Multidetector CT Angiography of the Aortoiliac System and Lower Extremities: A Prospective Comparison with Digital Subtraction Angiography Am. J. Roentgenol., April 1, 2003; 180(4): 1085 - 1091. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Swan, T. J. Carroll, T. W. Kennell, D. M. Heisey, F. R. Korosec, R. Frayne, C. A. Mistretta, and T. M. Grist Time-resolved Three-dimensional Contrast-enhanced MR Angiography of the Peripheral Vessels Radiology, October 1, 2002; 225(1): 43 - 52. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. F. Hany, T. J. Carroll, R. A. Omary, E. Esparza-Coss, F. R. Korosec, C. A. Mistretta, and T. M. Grist Aorta and Runoff Vessels: Single-Injection MR Angiography with Automated Table Movement Compared with Multiinjection Time-resolved MR Angiography—Initial Results Radiology, October 1, 2001; 221(1): 266 - 272. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Ruehm, T. F. Hany, T. Pfammatter, E. Schneider, M. Ladd, and J. F. Debatin Pelvic and Lower Extremity Arterial Imaging: Diagnostic Performance of Three-Dimensional Contrast-Enhanced MR Angiography Am. J. Roentgenol., April 1, 2000; 174(4): 1127 - 1135. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. M. Rofsky and M. A. Adelman MR Angiography in the Evaluation of Atherosclerotic Peripheral Vascular Disease Radiology, February 1, 2000; 214(2): 325 - 338. [Abstract] [Full Text] |
||||
![]() |
E. K. Yucel, C. M. Anderson, R. R. Edelman, T. M. Grist, R. A. Baum, W. J. Manning, A. Culebras, and W. Pearce Magnetic Resonance Angiography : Update on Applications for Extracranial Arteries Circulation, November 30, 1999; 100(22): 2284 - 2301. [Full Text] [PDF] |
||||
![]() |
J. F. M. Meaney, J. P. Ridgway, S. Chakraverty, I. Robertson, D. Kessel, A. Radjenovic, M. Kouwenhoven, A. Kassner, and M. A. Smith Stepping-Table Gadolinium- enhanced Digital Subtraction MR Angiography of the Aorta and Lower Extremity Arteries: Preliminary Experience Radiology, April 1, 1999; 211(1): 59 - 67. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |