Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Edelman, R. R.
Right arrow Articles by Warach, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Edelman, R. R.
Right arrow Articles by Warach, S.

Radiology, Vol 192, 513-520, Copyright © 1994 by Radiological Society of North America


ARTICLES

Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency

RR Edelman, B Siewert, DG Darby, V Thangaraj, AC Nobre, MM Mesulam and S Warach
Department of Radiology, Beth Israel Hospital, Boston, MA 02215.

PURPOSE: To create qualitative maps of cerebral blood flow (CBF) with the EPISTAR (echo-planar imaging and signal targeting with alternating radio frequency) technique. MATERIALS AND METHODS: The EPISTAR technique was performed in a pig model of hypercapnia and then tested in 26 volunteers by using various paradigms for cortical activation. Echo-planar images were acquired with and without use of a radio- frequency inversion pulse applied to inflowing arterial spins. A qualitative map of CBF was then created by subtracting the image obtained without the radio-frequency pulse from that obtained with the radio-frequency pulse. RESULTS: Progressively more distal portions of the tagged vessels were seen as the inflow time was lengthened until cortical enhancement was seen for inflow times of approximately 1 second or longer. Signal intensity increases from rest to sensorimotor activation ranged from 13% to 193%. CBF changes in the motor strip, primary visual cortex, and the motor area for eye movements were well localized to the cortical gray matter ribbon. CONCLUSION: The EPISTAR technique is a rapid, noninvasive means for creating qualitative maps of CBF.


This article has been cited by other articles:


Home page
NeuroscientistHome page
S.-G. Kim and M. Fukuda
Lessons from fMRI about Mapping Cortical Columns
Neuroscientist, June 1, 2008; 14(3): 287 - 299.
[Abstract] [PDF]


Home page
Am. J. Neuroradiol.Home page
G. Zaharchuk
Theoretical Basis of Hemodynamic MR Imaging Techniques to Measure Cerebral Blood Volume, Cerebral Blood Flow, and Permeability
AJNR Am. J. Neuroradiol., November 1, 2007; 28(10): 1850 - 1858.
[Abstract] [Full Text] [PDF]


Home page
J. Neurosci.Home page
C.-H. Moon, M. Fukuda, S.-H. Park, and S.-G. Kim
Neural Interpretation of Blood Oxygenation Level-Dependent fMRI Maps at Submillimeter Columnar Resolution
J. Neurosci., June 27, 2007; 27(26): 6892 - 6902.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E T Petersen, I Zimine, Y-C L Ho, and X Golay
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Br. J. Radiol., August 1, 2006; 79(944): 688 - 701.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Fenchel, P. Martirosian, J. Langanke, J. Giersch, S. Miller, N. I. Stauder, U. Kramer, C. D. Claussen, and F. Schick
Perfusion MR Imaging with FAIR True FISP Spin Labeling in Patients with and without Renal Artery Stenosis: Initial Experience
Radiology, March 1, 2006; 238(3): 1013 - 1021.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
C. Warmuth, M. Ruping, A. Forschler, H.-C. Koennecke, J. M. Valdueza, A. Kauert, S. J. Schreiber, R. Siekmann, and C. Zimmer
Dynamic Spin Labeling Angiography in Extracranial Carotid Artery Stenosis
AJNR Am. J. Neuroradiol., May 1, 2005; 26(5): 1035 - 1043.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
R. E. Latchaw, H. Yonas, G. J. Hunter, W. T.C. Yuh, T. Ueda, A. G. Sorensen, J. L. Sunshine, J. Biller, L. Wechsler, R. Higashida, et al.
Guidelines and Recommendations for Perfusion Imaging in Cerebral Ischemia: A Scientific Statement for Healthcare Professionals by the Writing Group on Perfusion Imaging, From the Council on Cardiovascular Radiology of the American Heart Association
Stroke, April 1, 2003; 34(4): 1084 - 1104.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Kikuchi, K. Murase, H. Miki, Y. Yasuhara, Y. Sugawara, T. Mochizuki, J. Ikezoe, and S. Ohue
Quantitative Evaluation of Mean Transit Times Obtained with Dynamic Susceptibility Contrast-Enhanced MR Imaging and with 133Xe SPECT in Occlusive Cerebrovascular Disease
Am. J. Roentgenol., July 1, 2002; 179(1): 229 - 235.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. S. Arbab, S. Aoki, K. Toyama, N. Miyazawa, H. Kumagai, T. Umeda, T. Arai, T. Araki, H. Kabasawa, and Y. Takahashi
Quantitative Measurement of Regional Cerebral Blood Flow with Flow-Sensitive Alternating Inversion Recovery Imaging: Comparison with [Iodine 123]-Iodoamphetamin Single Photon Emission CT
AJNR Am. J. Neuroradiol., March 1, 2002; 23(3): 381 - 388.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
T. Q. Duong, D.-S. Kim, K. Ugurbil, and S.-G. Kim
Localized cerebral blood flow response at submillimeter columnar resolution
PNAS, August 23, 2001; (2001) 191101098.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
A. Darquie, J.-B. Poline, C. Poupon, H. Saint-Jalmes, and D. Le Bihan
Transient decrease in water diffusion observed in human occipital cortex during visual stimulation
PNAS, July 13, 2001; (2001) 151125698.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. Poustchi-Amin, S. A. Mirowitz, J. J. Brown, R. C. McKinstry, and T. Li
Principles and Applications of Echo-planar Imaging: A Review for the General Radiologist
RadioGraphics, May 1, 2001; 21(3): 767 - 779.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
W. R. Bauer, K.-H. Hiller, P. Galuppo, S. Neubauer, J. Kopke, A. Haase, C. Waller, and G. Ertl
Fast High-Resolution Magnetic Resonance Imaging Demonstrates Fractality of Myocardial Perfusion in Microscopic Dimensions
Circ. Res., February 16, 2001; 88(3): 340 - 346.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. R. Petrella and J. M. Provenzale
MR Perfusion Imaging of the Brain: Techniques and Applications
Am. J. Roentgenol., July 1, 2000; 175(1): 207 - 219.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Cha, E. A. Knopp, G. Johnson, A. Litt, J. Glass, M. L. Gruber, S. Lu, and D. Zagzag
Dynamic Contrast-enhanced T2*-weighted MR Imaging of Recurrent Malignant Gliomas Treated with Thalidomide and Carboplatin
AJNR Am. J. Neuroradiol., May 1, 2000; 21(5): 881 - 890.
[Abstract] [Full Text]


Home page
Am. J. PsychiatryHome page
P. M. Doraiswamy, J. MacFall, K. R. R. Krishnan, C. O'Connor, X. Wan, M. Benaur, M. Lewandowski, and M. Fortner
Magnetic Resonance Assessment of Cerebral Perfusion in Depressed Cardiac Patients: Preliminary Findings
Am J Psychiatry, October 1, 1999; 156(10): 1641 - 1643.
[Abstract] [Full Text]


Home page
RadiologyHome page
S. B. Reeder, A. A. Holmes, E. R. McVeigh, and J. R. Forder
Simultaneous Noninvasive Determination of Regional Myocardial Perfusion and Oxygen Content in Rabbits: Toward Direct Measurement of Myocardial Oxygen Consumption at MR Imaging
Radiology, September 1, 1999; 212(3): 739 - 747.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
A. Kastrup, T.-Q. Li, G. H. Glover, and M. E. Moseley
Cerebral Blood Flow-Related SignalChanges during Breath-Holding
AJNR Am. J. Neuroradiol., August 1, 1999; 20(7): 1233 - 1238.
[Abstract] [Full Text]


Home page
RadiologyHome page
N. J. Beauchamp Jr, P. B. Barker, P. Y. Wang, and P. C. M. vanZijl
Imaging of Acute Cerebral Ischemia
Radiology, August 1, 1999; 212(2): 307 - 324.
[Abstract] [Full Text]


Home page
RadiologyHome page
E. A. Knopp, S. Cha, G. Johnson, A. Mazumdar, J. G. Golfinos, D. Zagzag, D. C. Miller, P. J. Kelly, and I. I. Kricheff
Glial Neoplasms: Dynamic Contrast-enhanced T2*-weighted MR Imaging
Radiology, June 1, 1999; 211(3): 791 - 798.
[Abstract] [Full Text]


Home page
RadiologyHome page
H. Yamada, Y. Koshimoto, N. Sadato, Y. Kawashima, M. Tanaka, C. Tsuchida, M. Maeda, Y. Yonekura, and Y. Ishii
Crossed Cerebellar Diaschisis: Assessment with Dynamic Susceptibility Contrast MR Imaging
Radiology, February 1, 1999; 210(2): 558 - 562.
[Abstract] [Full Text]


Home page
StrokeHome page
B. Siewert, P. A. Wielopolski, G. Schlaug, R. R. Edelman, and S. Warach
STAR MR Angiography for Rapid Detection of Vascular Abnormalities in Patients With Acute Cerebrovascular Disease
Stroke, June 1, 1997; 28(6): 1211 - 1215.
[Abstract] [Full Text]


Home page
NeuroscientistHome page
S. Warach
Review : Mapping Brain Pathophysiology and Higher Cortical Function with Magnetic Resonance Imaging
Neuroscientist, July 1, 1995; 1(4): 221 - 235.
[Abstract] [PDF]


Home page
ScienceHome page
J. Sanes, J. Donoghue, V Thangaraj, R. Edelman, and S Warach
Shared neural substrates controlling hand movements in human motor cortex
Science, June 23, 1995; 268(5218): 1775 - 1777.
[Abstract] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
A. Darquie, J.-B. Poline, C. Poupon, H. Saint-Jalmes, and D. Le Bihan
Transient decrease in water diffusion observed in human occipital cortex during visual stimulation
PNAS, July 31, 2001; 98(16): 9391 - 9395.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
T. Q. Duong, D.-S. Kim, K. Ugurbil, and S.-G. Kim
Localized cerebral blood flow response at submillimeter columnar resolution
PNAS, September 11, 2001; 98(19): 10904 - 10909.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Cha, E. A. Knopp, G. Johnson, S. G. Wetzel, A. W. Litt, and D. Zagzag
Intracranial Mass Lesions: Dynamic Contrast-enhanced Susceptibility-weighted Echo-planar Perfusion MR Imaging
Radiology, April 1, 2002; 223(1): 11 - 29.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.