PURPOSE: To evaluate detection of intracranial aneurysms with helical computed tomography (CT) and compare the results with those of conventional angiography and magnetic resonance (MR) angiography. MATERIALS AND METHODS: Twenty-one patients with 30 intracranial aneurysms were studied with helical CT and conventional angiography; 17 of the patients (24 aneurysms) also underwent MR angiography. RESULTS: All aneurysms 3 mm or larger in greatest dimension were seen with helical CT and MR angiography; no aneurysms smaller than 3 mm were apparent with either modality. Of the 21 aneurysms demonstrated with both helical CT and MR angiography, 11 were seen equally well with both techniques; six were seen better with helical CT owing to flow-related or motion artifact at MR angiography, and four were seen better with MR angiography because calcium partially obscured them at helical CT. CONCLUSION: Helical CT is a promising noninvasive method of imaging the intracranial vasculature and is comparable with standard MR angiographic techniques in demonstrating aneurysms.
This article has been cited by other articles:
![]() |
M. Romijn, H.A.F. G. van Andel, M.A. van Walderveen, M.E. Sprengers, J.C. van Rijn, W.J. van Rooij, H.W. Venema, C.A. Grimbergen, G.J. den Heeten, and C.B. Majoie Diagnostic Accuracy of CT Angiography with Matched Mask Bone Elimination for Detection of Intracranial Aneurysms: Comparison with Digital Subtraction Angiography and 3D Rotational Angiography AJNR Am. J. Neuroradiol., January 1, 2008; 29(1): 134 - 139. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Lubicz, M. Levivier, O. Francois, P. Thoma, N. Sadeghi, L. Collignon, and D. Baleriaux Sixty-Four-Row Multisection CT Angiography for Detection and Evaluation of Ruptured Intracranial Aneurysms: Interobserver and Intertechnique Reproducibility AJNR Am. J. Neuroradiol., November 1, 2007; 28(10): 1949 - 1955. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Sakamoto, Y. Kiura, M. Shibukawa, S. Ohba, K. Arita, and K. Kurisu Subtracted 3D CT Angiography for Evaluation of Internal Carotid Artery Aneurysms: Comparison with Conventional Digital Subtraction Angiography AJNR Am. J. Neuroradiol., June 1, 2006; 27(6): 1332 - 1337. [Abstract] [Full Text] [PDF] |
||||
![]() |
D.Y. Yoon, C.S. Choi, K.H. Kim, and B.-M. Cho Multidetector-Row CT Angiography of Cerebral Vasospasm after Aneurysmal Subarachnoid Hemorrhage: Comparison of Volume-Rendered Images and Digital Subtraction Angiography. AJNR Am. J. Neuroradiol., February 1, 2006; 27(2): 370 - 377. [Abstract] [Full Text] [PDF] |
||||
![]() |
B.F. Tomandl, T. Hammen, E. Klotz, H. Ditt, B. Stemper, and M. Lell Bone-Subtraction CT Angiography for the Evaluation of Intracranial Aneurysms AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 55 - 59. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. K. Jayakrishnan, P. M. White, D. Aitken, P. Crane, A. D. McMahon, and E. M. Teasdale Subtraction Helical CT Angiography of Intra- and Extracranial Vessels: Technical Considerations and Preliminary Experience AJNR Am. J. Neuroradiol., March 1, 2003; 24(3): 451 - 455. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Mallouhi, S. Felber, A. Chemelli, A. Dessl, A. Auer, M. Schocke, W. R. Jaschke, and P. Waldenberger Detection and Characterization of Intracranial Aneurysms with MR Angiography: Comparison of Volume-Rendering and Maximum-Intensity-Projection Algorithms Am. J. Roentgenol., January 1, 2003; 180(1): 55 - 64. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Villablanca, R. Jahan, P. Hooshi, S. Lim, G. Duckwiler, A. Patel, J. Sayre, N. Martin, J. Frazee, J. Bentson, et al. Detection and Characterization of Very Small Cerebral Aneurysms by Using 2D and 3D Helical CT Angiography AJNR Am. J. Neuroradiol., August 1, 2002; 23(7): 1187 - 1198. [Abstract] [Full Text] [PDF] |
||||
![]() |
U J Schoepf, C R Becker, R D Bruening, B M Ohnesorge, A Huber, L-G Haw, H Hildebrandt, and M F Reiser Multislice CT angiography Imaging, December 15, 2001; 13(5): 357 - 365. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. F. Tomandl, P. Hastreiter, C. Rezk-Salama, K. Engel, T. Ertl, W. J. Huk, R. Naraghi, O. Ganslandt, C. Nimsky, and K. E. W. Eberhardt Local and Remote Visualization Techniques for Interactive Direct Volume Rendering in Neuroradiology RadioGraphics, November 1, 2001; 21(6): 1561 - 1572. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. White, E. M. Teasdale, J. M. Wardlaw, and V. Easton Intracranial Aneurysms: CT Angiography and MR Angiography for Detection—Prospective Blinded Comparison in a Large Patient Cohort Radiology, June 1, 2001; 219(3): 739 - 749. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Anxionnat, S. Bracard, X. Ducrocq, Y. Trousset, L. Launay, E. Kerrien, M. Braun, R. Vaillant, F. Scomazzoni, A. Lebedinsky, et al. Intracranial Aneurysms: Clinical Value of 3D Digital Subtraction Angiography in the Therapeutic Decision and Endovascular Treatment Radiology, March 1, 2001; 218(3): 799 - 808. [Abstract] [Full Text] |
||||
![]() |
H. W. Venema, F. J. H. Hulsmans, and G. J. den Heeten CT Angiography of the Circle of Willis and Intracranial Internal Carotid Arteries: Maximum Intensity Projection with Matched Mask Bone Elimination--Feasibility Study Radiology, March 1, 2001; 218(3): 893 - 898. [Abstract] [Full Text] |
||||
![]() |
P. M. White, J. M. Wardlaw, and V. Easton Can Noninvasive Imaging Accurately Depict Intracranial Aneurysms? A Systematic Review Radiology, November 1, 2000; 217(2): 361 - 370. [Abstract] [Full Text] |
||||
![]() |
W. M. Adams, R. D. Laitt, and A. Jackson The Role of MR Angiography in the Pretreatment Assessment of Intracranial Aneurysms: A Comparative Study AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1618 - 1628. [Abstract] [Full Text] |
||||
![]() |
O. Coskun, M. Hamon, G. Catroux, L. Gosme, P. Courthéoux, and J. Théron Carotid-cavernous Fistulas: Diagnosis with Spiral CT Angiography AJNR Am. J. Neuroradiol., April 1, 2000; 21(4): 712 - 716. [Abstract] [Full Text] |
||||
![]() |
Y. Korogi, M. Takahashi, K. Katada, Y. Ogura, K. Hasuo, M. Ochi, H. Utsunomiya, T. Abe, and S. Imakita Intracranial Aneurysms: Detection with Three-dimensional CT Angiography with Volume Rendering—Comparison with Conventional Angiographic and Surgical Findings Radiology, May 1, 1999; 211(2): 497 - 506. [Abstract] [Full Text] |
||||
![]() |
T.-S. Chung, J.-Y. Joo, S.-K. Lee, D. Chien, and G. Laub Evaluation of Cerebral Aneurysms with High-Resolution MR Angiography Using a Section-Interpolation Technique: Correlation with Digital Subtraction Angiography AJNR Am. J. Neuroradiol., February 1, 1999; 20(2): 229 - 235. [Abstract] [Full Text] |
||||
![]() |
R. A. Alberico, P. Barnes, R. L. Robertson, and P. E. Burrows Helical CT Angiography: Dynamic Cerebrovascular Imaging in Children AJNR Am. J. Neuroradiol., February 1, 1999; 20(2): 328 - 334. [Abstract] [Full Text] |
||||
![]() |
S. D Chang and G. K Steinberg Management of intracranial aneurysms Vascular Medicine, November 1, 1998; 3(4): 315 - 326. [Abstract] [PDF] |
||||
![]() |
X. L. Zhu, M. S. Y. Chan, and W. S. Poon Spontaneous Intracranial Hemorrhage: Which Patients Need Diagnostic Cerebral Angiography? : A Prospective Study of 206 Cases and Review of the Literature Stroke, July 1, 1997; 28(7): 1406 - 1409. [Abstract] [Full Text] |
||||
![]() |
W. I. Schievink Intracranial Aneurysms N. Engl. J. Med., January 2, 1997; 336(1): 28 - 40. [Full Text] [PDF] |
||||