Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Posse, S.
Right arrow Articles by Le Bihan, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Posse, S.
Right arrow Articles by Le Bihan, D.

Radiology, Vol 192, 733-738, Copyright © 1994 by Radiological Society of North America


ARTICLES

Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain

S Posse, C DeCarli and D Le Bihan
Department of Diagnostic Radiology, National Institutes of Health, Bethesda, MD 20892.

PURPOSE: To demonstrate the feasibility of three-dimensional echo- planar spectroscopic imaging (EPSI) at short echo time (13 msec) with a conventional clinical imager in the human brain. MATERIALS AND METHODS: Periodic inversions of a readout gradient were used during data acquisition to simultaneously encode chemical shift and one spatial dimension in one excitation. Aliasing artifacts were avoided with a modified acquisition-and-processing method based on oversampling. A double outer-volume suppression technique that adapts to the ovoid brain shape was used to strongly reduce extracranial lipid resonances. RESULTS: Three-dimensional spatial encoding in vivo of eight sections with 32 x 32 voxels each (0.75 cm3) was performed in 34 minutes with four signal averages. The spectral resolution and signal-to-noise ratio (S/N) of resonances of inositol, choline, creatine, glutamate and glutamine, and N-acetyl aspartate were consistent with those previously recorded with conventional phase encoding. CONCLUSION: EPSI substantially reduces acquisition time for three-dimensional spatial encoding and yields a spectral quality similar to that obtained with conventional techniques without affecting the S/N per unit time and unit volume.


This article has been cited by other articles:


Home page
Molecular Cancer TherapeuticsHome page
S. J. Nelson
Multivoxel Magnetic Resonance Spectroscopy of Brain Tumors
Mol. Cancer Ther., May 1, 2003; 2(5): 497 - 507.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.