Radiology, Vol 193, 173-180, Copyright © 1994 by Radiological Society of North America
ARTICLES |
JN Rydberg, CA Hammond, RC Grimm, BJ Erickson, CR Jack Jr, J Huston 3rd and SJ Riederer
Department of Diagnostic Radiology, Mayo Clinic and Foundation, Rochester, MN 55905.
PURPOSE: To evaluate fast fluid-attenuated inversion-recovery (FLAIR) technique for imaging brain abnormalities. MATERIALS AND METHODS: A fast FLAIR sequence was developed that provided 36 5-mm contiguous sections in 5 minutes 8 seconds. Resulting images were compared with dual-echo T2-weighted spin-echo images of 41 consecutive patients with brain abnormalities. RESULTS: Contrast and contrast-to-noise ratios (C/Ns) (for contrast between the lesion and background and between the lesion and cerebrospinal fluid) for fast FLAIR exceeded the corresponding values for T2-weighted spin-echo images for all but the second-echo lesion-to-background C/N. Fast FLAIR provided equivalent or greater overall lesion conspicuity and enabled greater lesion detection in 98% and 100%, respectively, of the evaluations. Fast FLAIR images more often had image artifact, but this did not interfere with image interpretation in a significantly (P < or = .05) greater number of evaluations. CONCLUSION: Fast FLAIR provides images that are superior to proton-density- and T2-weighted images for many image quality criteria.
This article has been cited by other articles:
![]() |
C. R. Jack Jr, S. D. Weigand, M. M. Shiung, S. A. Przybelski, P. C. O'Brien, J. L. Gunter, D. S. Knopman, B. F. Boeve, G. E. Smith, and R. C. Petersen Atrophy rates accelerate in amnestic mild cognitive impairment Neurology, May 6, 2008; 70(19_Part_2): 1740 - 1752. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. L. Stuckey, T. D. Goh, T. Heffernan, and D. Rowan Hyperintensity in the Subarachnoid Space on FLAIR MRI Am. J. Roentgenol., October 1, 2007; 189(4): 913 - 921. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. S.C. Korf, L. R. White, P. Scheltens, and L. J. Launer Brain Aging in Very Old Men With Type 2 Diabetes: The Honolulu-Asia Aging Study Diabetes Care, October 1, 2006; 29(10): 2268 - 2274. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Cianfoni, M.G.M. Martin, J. Du, J.R. Hesselink, S.G. Imbesi, W.G. Bradley, and G.M. Bydder Artifact simulating subarachnoid and intraventricular hemorrhage on single-shot, fast spin-echo fluid-attenuated inversion recovery images caused by head movement: A trap for the unwary. AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 843 - 849. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Ercan, S. Gultekin, H. Celik, T. E. Tali, Y. A. Oner, and G. Erbas Diagnostic Value of Contrast-Enhanced Fluid-Attenuated Inversion Recovery MR Imaging of Intracranial Metastases AJNR Am. J. Neuroradiol., May 1, 2004; 25(5): 761 - 765. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Bastos Leite, E. C.W. van Straaten, P. Scheltens, G. Lycklama, and F. Barkhof Thalamic Lesions in Vascular Dementia: Low Sensitivity of Fluid-Attenuated Inversion Recovery (FLAIR) Imaging Stroke, February 1, 2004; 35(2): 415 - 419. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. J. Nelson Multivoxel Magnetic Resonance Spectroscopy of Brain Tumors Mol. Cancer Ther., May 1, 2003; 2(5): 497 - 507. [Abstract] [Full Text] [PDF] |
||||
![]() |
U C Wieshmann Clinical application of neuroimaging in epilepsy J. Neurol. Neurosurg. Psychiatry, April 1, 2003; 74(4): 466 - 470. [Abstract] [Full Text] [PDF] |
||||
![]() |
I L. Tan, R. A. van Schijndel, P. J. W. Pouwels, H. J. Ader, and F. Barkhof Serial Isotropic Three-Dimensional Fast FLAIR Imaging: Using Image Registration and Subtraction to Reveal Active Multiple Sclerosis Lesions Am. J. Roentgenol., September 1, 2002; 179(3): 777 - 782. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Rovira, J. Cordoba, F. Sanpedro, E. Grive, A. Rovira-Gols, and J. Alonso Normalization of T2 signal abnormalities in hemispheric white matter with liver transplant Neurology, August 13, 2002; 59(3): 335 - 341. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. K. Singh, N. E. Leeds, and L. E. Ginsberg MR Imaging of Leptomeningeal Metastases: Comparison of Three Sequences AJNR Am. J. Neuroradiol., May 1, 2002; 23(5): 817 - 821. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.-M. Wu, D. M. Yousem, H.-W. Chung, W.-Y. Guo, C.-Y. Chang, and C.-Y. Chen Influence of Imaging Parameters on High-Intensity Cerebrospinal Fluid Artifacts in Fast-FLAIR MR Imaging AJNR Am. J. Neuroradiol., March 1, 2002; 23(3): 393 - 399. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. M. Frohman, H. Zhang, P. D. Kramer, J. Fleckenstein, K. Hawker, M. K. Racke, and T. C. Frohman MRI characteristics of the MLF in MS patients with chronic internuclear ophthalmoparesis Neurology, September 11, 2001; 57(5): 762 - 768. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Chen, F. Ikawa, K. Kurisu, K. Arita, J. Takaba, and Y. Kanou Quantitative MR Evaluation of Intracranial Epidermoid Tumors by Fast Fluid-attenuated Inversion Recovery Imaging and Echo-planar Diffusion-weighted Imaging AJNR Am. J. Neuroradiol., June 1, 2001; 22(6): 1089 - 1096. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. H. Herlihy, J. V. Hajnal, W. L. Curati, N. Virji, A. Oatridge, B. K. Puri, and G. M. Bydder Reduction of CSF and Blood Flow Artifacts on FLAIR Images of the Brain with k-Space Reordered by Inversion Time at each Slice Position (KRISP) AJNR Am. J. Neuroradiol., May 1, 2001; 22(5): 896 - 904. [Abstract] [Full Text] |
||||
![]() |
R. Bakshi, S. Ariyaratana, R. H. B. Benedict, and L. Jacobs Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Detects Cortical and Juxtacortical Multiple Sclerosis Lesions Arch Neurol, May 1, 2001; 58(5): 742 - 748. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. H. Herskovits, R. Itoh, and E. R. Melhem Accuracy for Detection of Simulated Lesions: Comparison of Fluid-Attenuated Inversion-Recovery, Proton Density-Weighted, and T2-Weighted Synthetic Brain MR Imaging Am. J. Roentgenol., May 1, 2001; 176(5): 1313 - 1318. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. G. Filippi, A. M. Ulug, D. Lin, L. A. Heier, and R. D. Zimmerman Hyperintense Signal Abnormality in Subarachnoid Spaces and Basal Cisterns on MR Images of Children Anesthetized with Propofol: New Fluid-attenuated Inversion Recovery Finding AJNR Am. J. Neuroradiol., February 1, 2001; 22(2): 394 - 399. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. R. Melhem and R. Itoh Effect of T1 Relaxation Time on Lesion Contrast Enhancement in FLAIR MR Imaging: A Study Using Computer-Generated Brain Maps Am. J. Roentgenol., February 1, 2001; 176(2): 537 - 539. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. K. Singh, J. M. Agris, N. E. Leeds, and L. E. Ginsberg Intracranial Leptomeningeal Metastases: Comparison of Depiction at FLAIR and Contrast-enhanced MR Imaging Radiology, October 1, 2000; 217(1): 50 - 53. [Abstract] [Full Text] |
||||
![]() |
J. P. Mugler III, S. Bao, R. V. Mulkern, C. R. G. Guttmann, R. L. Robertson, F. A. Jolesz, and J. R. Brookeman Optimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the Brain Radiology, September 1, 2000; 216(3): 891 - 899. [Abstract] [Full Text] |
||||
![]() |
N. Hirono, H. Kitagaki, H. Kazui, M. Hashimoto, and E. Mori Impact of White Matter Changes on Clinical Manifestation of Alzheimer's Disease : A Quantitative Study Stroke, September 1, 2000; 31(9): 2182 - 2188. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kamran, V. Bates, R. Bakshi, P. Wright, W. Kinkel, and R. Miletich Significance of hyperintense vessels on FLAIR MRI in acute stroke Neurology, July 25, 2000; 55(2): 265 - 269. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Tanaka, T. Abe, K. Kojima, H. Nishimura, and N. Hayabuchi Applicability and Advantages of Flow artifact-insensitive Fluid-attenuated Inversion-recovery MR Sequences for Imaging the Posterior Fossa AJNR Am. J. Neuroradiol., June 1, 2000; 21(6): 1095 - 1098. [Abstract] [Full Text] |
||||
![]() |
T. Hirai, Y. Korogi, K. Yoshizumi, Y. Shigematsu, T. Sugahara, and M. Takahashi Limbic Lobe of the Human Brain: Evaluation with Turbo Fluid-attenuated Inversion-Recovery MR Imaging Radiology, May 1, 2000; 215(2): 470 - 475. [Abstract] [Full Text] |
||||
![]() |
R. Bakshi, S. D. Caruthers, V. Janardhan, and M. Wasay Intraventricular CSF Pulsation Artifact on Fast Fluid-Attenuated Inversion-Recovery MR Images: Analysis of 100 Consecutive Normal Studies AJNR Am. J. Neuroradiol., March 1, 2000; 21(3): 503 - 508. [Abstract] [Full Text] |
||||
![]() |
M. Filippi, M. A. Rocca, M. Wiessmann, S. Mennea, M. Cercignani, T. A. Yousry, M. P. Sormani, and G. Comi A Comparison of MR Imaging with Fast-FLAIR, HASTE-FLAIR, and EPI-FLAIR Sequences in the Assessment of Patients with Multiple Sclerosis AJNR Am. J. Neuroradiol., November 1, 1999; 20(10): 1931 - 1938. [Abstract] [Full Text] |
||||
![]() |
D. M. Moriarty, A. J. Blackshaw, P. R. Talbot, H. L. Griffiths, J. S. Snowden, V. F. Hillier, S. Capener, R. D. Laitt, and A. Jackson Memory Dysfunction in Multiple Sclerosis Corresponds to Juxtacortical Lesion Load on Fast Fluid-Attenuated Inversion-Recovery MR Images AJNR Am. J. Neuroradiol., November 1, 1999; 20(10): 1956 - 1962. [Abstract] [Full Text] |
||||
![]() |
J. W. Murakami, E. Weinberger, and D. W. W. Shaw Normal Myelination of the Pediatric Brain Imaged with Fluid-Attenuated Inversion-Recovery (FLAIR)MR Imaging AJNR Am. J. Neuroradiol., September 1, 1999; 20(8): 1406 - 1411. [Abstract] [Full Text] |
||||
![]() |
T. Okuda, Y. Korogi, Y. Shigematsu, T. Sugahara, T. Hirai, I. Ikushima, L. Liang, and M. Takahashi Brain Lesions: When Should Fluid-attenuated Inversion-Recovery Sequences Be Used in MR Evaluation? Radiology, September 1, 1999; 212(3): 793 - 798. [Abstract] [Full Text] |
||||
![]() |
N. J. Beauchamp Jr, P. B. Barker, P. Y. Wang, and P. C. M. vanZijl Imaging of Acute Cerebral Ischemia Radiology, August 1, 1999; 212(2): 307 - 324. [Abstract] [Full Text] |
||||
![]() |
Rovaris, Comi, M. Rocca, Cercignani, Colombo, Santuccio, and Filippi Relevance of Hypointense Lesions on Fast Fluid-Attenuated Inversion Recovery MR Images as a Marker of Disease Severity in Cases of Multiple AJNR Am. J. Neuroradiol., May 1, 1999; 20(5): 813 - 820. [Abstract] [Full Text] |
||||
![]() |
S. Palmer, W. G. Bradley, D.-Y. Chen, and S. Patel Subcallosal Striations: Early Findings of Multiple Sclerosis on Sagittal, Thin-Section, Fast FLAIR MR Images Radiology, January 1, 1999; 210(1): 149 - 153. [Abstract] [Full Text] |
||||
![]() |
J. C. Corvol, C. Oppenheim, R. Manai, M. Logak, D. Dormont, Y. Samson, C. Marsault, and G. Rancurel Diffusion-Weighted Magnetic Resonance Imaging in a Case of Cerebral Venous Thrombosis Stroke, December 1, 1998; 29(12): 2649 - 2652. [Abstract] [Full Text] [PDF] |
||||
![]() |
M L Gawne-Cain, J I O'Riordan, A Coles, B Newell, A J Thompson, and D H Miller MRI lesion volume measurement in multiple sclerosis and its correlation with disability: a comparison of fast fluid attenuated inversion recovery (fFLAIR) and spin echo sequences J. Neurol. Neurosurg. Psychiatry, February 1, 1998; 64(2): 197 - 203. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Knauth, S. Ries, S. Pohimann, T. Kerby, M. Forsting, M. Daffertshofer, M. Hennerici, and K. Sartor Cohort study of multiple brain lesions in sport divers: role of a patent foramen ovale BMJ, March 8, 1997; 314(7082): 701 - 701. [Abstract] [Full Text] |
||||
![]() |
M. Brant-Zawadzki, D. Atkinson, M. Detrick, W. G. Bradley, and G. Scidmore Fluid-Attenuated Inversion Recovery (FLAIR) for Assessment of Cerebral Infarction: Initial Clinical Experience in 50 Patients Stroke, July 1, 1996; 27(7): 1187 - 1191. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |