Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jackman, R. J.
Right arrow Articles by Marzoni, F. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jackman, R. J.
Right arrow Articles by Marzoni, F. A., Jr

Radiology, Vol 193, 91-95, Copyright © 1994 by Radiological Society of North America


ARTICLES

Stereotaxic large-core needle biopsy of 450 nonpalpable breast lesions with surgical correlation in lesions with cancer or atypical hyperplasia

RJ Jackman, KW Nowels, MJ Shepard, SI Finkelstein and FA Marzoni Jr
Department of Radiology, Palo Alto Medical Clinic, CA 94301.

PURPOSE: To determine whether histologic findings of cancer or atypical hyperplasia at large-core needle biopsy (LCNB) of nonpalpable breast lesions match histologic findings at excision. MATERIALS AND METHODS: Stereotaxic LCNB was performed with an automated prone unit, biopsy gun, and 14-gauge cutting needles in 450 nonpalpable breast lesions. Lesions classified as carcinoma or atypical ductal hyperplasia (ADH) at histologic examination after LCNB were excised. A pathologist retrospectively compared core and excisional histologic findings. RESULTS: Histologic comparison was performed in 116 of 135 carcinomas after LCNB. Histologic findings were concordant in 99 carcinomas. Partial discordance in 17 carcinomas led to an additional surgical procedure in one case. Histologic comparison was performed in 16 of 19 ADHs diagnosed with LCNB. Histologic findings were concordant in five and discordant in 11 ADHs. CONCLUSION: LCNB findings of carcinoma are accurate and allow definitive therapeutic surgery, including mastectomy. LCNB findings of ADH are inaccurate, and excisional biopsy is necessary.


This article has been cited by other articles:


Home page
RadiologyHome page
G. Schueller, S. Jaromi, L. Ponhold, M. Fuchsjaeger, M. Memarsadeghi, M. Rudas, M. Weber, L. Liberman, and T. H. Helbich
US-guided 14-gauge Core-Needle Breast Biopsy: Results of a Validation Study in 1352 Cases
Radiology, August 1, 2008; 248(2): 406 - 413.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. F. Brem, M. C. Lechner, R. J. Jackman, J. A. Rapelyea, W. P. Evans, L. E. Philpotts, J. Hargreaves, and S. Wasden
Lobular Neoplasia at Percutaneous Breast Biopsy: Variables Associated with Carcinoma at Surgical Excision
Am. J. Roentgenol., March 1, 2008; 190(3): 637 - 641.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Pathol.Home page
E A Rakha and I O Ellis
An overview of assessment of prognostic and predictive factors in breast cancer needle core biopsy specimens
J. Clin. Pathol., December 1, 2007; 60(12): 1300 - 1306.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, A. E. Holland, D. Marjan, M. P. Murray, L. Bartella, E. A. Morris, D. D. Dershaw, and R. T. Wynn
Underestimation of Atypical Ductal Hyperplasia at MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy
Am. J. Roentgenol., March 1, 2007; 188(3): 684 - 690.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. C. Mahoney, T. M. Robinson-Smith, and E. A. Shaughnessy
Lobular Neoplasia at 11-Gauge Vacuum-Assisted Stereotactic Biopsy: Correlation with Surgical Excisional Biopsy and Mammographic Follow-Up
Am. J. Roentgenol., October 1, 2006; 187(4): 949 - 954.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
R. M. Golub, C. L. Bennett, T. Stinson, L. Venta, and M. Morrow
Cost Minimization Study of Image-Guided Core Biopsy Versus Surgical Excisional Biopsy for Women With Abnormal Mammograms
J. Clin. Oncol., June 15, 2004; 22(12): 2430 - 2437.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. C. Foster, M. A. Helvie, N. E. Gregory, M. Rebner, A. V. Nees, and C. Paramagul
Lobular Carcinoma in Situ or Atypical Lobular Hyperplasia at Core-Needle Biopsy: Is Excisional Biopsy Necessary?
Radiology, June 1, 2004; 231(3): 813 - 819.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. J. Kirshenbaum, T. Voruganti, C. Overbeeke, M. D. Kirshenbaum, P. Patel, G. Kaplan, V. Maker, C. August, and R. P. Cavallino
Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions Using a Conventional Mammography Unit with an Add-On Device
Am. J. Roentgenol., August 1, 2003; 181(2): 527 - 531.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Pathol.Home page
P J Carder and J C Liston
Will the spectrum of lesions prompting a "B3" breast core biopsy increase the benign biopsy rate?
J. Clin. Pathol., February 1, 2003; 56(2): 133 - 138.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. E. Philpotts, R. J. Hooley, and C. H. Lee
Comparison of Automated Versus Vacuum-Assisted Biopsy Methods for Sonographically Guided Core Biopsy of the Breast
Am. J. Roentgenol., February 1, 2003; 180(2): 347 - 351.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
S. Pandelidis, D. Heilman, D. Jones, K. Stough, J. Trapeni, and Y. Suliman
Accuracy of 11-Gauge Vacuum-Assisted Core Biopsy of Mammographic Breast Lesions
Ann. Surg. Oncol., January 1, 2003; 10(1): 43 - 47.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. J. Brenner, R. J. Jackman, S. H. Parker, W. P. Evans III, L. Philpotts, B. M. Deutch, M. C. Lechner, D. Lehrer, P. Sylvan, R. Hunt, et al.
Percutaneous Core Needle Biopsy of Radial Scars of the Breast: When Is Excision Necessary?
Am. J. Roentgenol., November 1, 2002; 179(5): 1179 - 1184.
[Abstract] [Full Text] [PDF]


Home page
CA Cancer J ClinHome page
M. Morrow, E. A. Strom, L. W. Bassett, D. D. Dershaw, B. Fowble, J. R. Harris, F. O'Malley, S. J. Schnitt, S. E. Singletary, and D. P. Winchester
Standard for the Management of Ductal Carcinoma In Situ of the Breast (DCIS)
CA Cancer J Clin, September 1, 2002; 52(5): 256 - 276.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
G. F. Tillman, S. G. Orel, M. D. Schnall, D. J. Schultz, J. E. Tan, and L. J. Solin
Effect of Breast Magnetic Resonance Imaging on the Clinical Management of Women With Early-Stage Breast Carcinoma
J. Clin. Oncol., August 15, 2002; 20(16): 3413 - 3423.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Jackman, R. L. Birdwell, and D. M. Ikeda
Atypical Ductal Hyperplasia: Can Some Lesions Be Defined as Probably Benign after Stereotactic 11-gauge Vacuum-assisted Biopsy, Eliminating the Recommendation for Surgical Excision?
Radiology, August 1, 2002; 224(2): 548 - 554.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Georgian-Smith, C. D'Orsi, E. Morris, C. F. Clark Jr., E. Liberty, and C. D. Lehman
Stereotactic Biopsy of the Breast Using an Upright Unit, a Vacuum-Suction Needle, and a Lateral Arm-Support System
Am. J. Roentgenol., April 1, 2002; 178(4): 1017 - 1024.
[Abstract] [Full Text] [PDF]


Home page
Arch SurgHome page
B. N. Fahy, R. J. Bold, P. D. Schneider, V. Khatri, and J. E. Goodnight Jr
Cost-Benefit Analysis of Biopsy Methods for Suspicious Mammographic Lesions
Arch Surg, September 1, 2001; 136(9): 990 - 995.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Orel and M. D. Schnall
MR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer
Radiology, July 1, 2001; 220(1): 13 - 30.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Brenner, L. W. Bassett, L. L. Fajardo, D. D. Dershaw, W. P. Evans III, R. Hunt, C. Lee, I. Tocino, P. Fisher, M. McCombs, et al.
Stereotactic Core-Needle Breast Biopsy: A Multi-institutional Prospective Trial
Radiology, March 1, 2001; 218(3): 866 - 872.
[Abstract] [Full Text]


Home page
RadiologyHome page
P. C. Stomper, C. C. Stewart, and D. L. Stoler
Stereotactic Core Biopsy Breast and Blood Cell By-products: A Source of Material for Molecular Genetics Research-Initial Experience
Radiology, March 1, 2001; 218(3): 881 - 885.
[Abstract] [Full Text]


Home page
J. Clin. Pathol.Home page
A E K Ibrahim, A C Bateman, J M Theaker, J L Low, B Addis, P Tidbury, C Rubin, M Briley, and G T Royle
The role and histological classification of needle core biopsy in comparison with fine needle aspiration cytology in the preoperative assessment of impalpable breast lesions
J. Clin. Pathol., February 1, 2001; 54(2): 121 - 125.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Jackman, F. Burbank, S. H. Parker, W. P. Evans III, M. C. Lechner, T. R. Richardson, A. A. Smid, H. B. Borofsky, C. H. Lee, H. M. Goldstein, et al.
Stereotactic Breast Biopsy of Nonpalpable Lesions: Determinants of Ductal Carcinoma in Situ Underestimation Rates
Radiology, February 1, 2001; 218(2): 497 - 502.
[Abstract] [Full Text]


Home page
RadiologyHome page
C. H. Lee, D. Carter, L. E. Philpotts, M. E. Couce, L. J. Horvath, R. C. Lange, and I. Tocino
Ductal Carcinoma in Situ Diagnosed with Stereotactic Core Needle Biopsy: Can Invasion Be Predicted?
Radiology, November 1, 2000; 217(2): 466 - 470.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
M. L. R. Darling, D. N. Smith, S. C. Lester, C. Kaelin, D.-L. G. Selland, C. M. Denison, P. J. DiPiro, D. I. Rose, E. Rhei, and J. E. Meyer
Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy: Results of Surgical Excision
Am. J. Roentgenol., November 1, 2000; 175(5): 1341 - 1346.
[Abstract] [Full Text] [PDF]


Home page
INT J SURG PATHOLHome page
D. B. Troxel
Diagnostic Errors in Surgical Pathology Uncovered by a Review of Malpractice Claims: Part 111. Breast Biopsies
International Journal of Surgical Pathology, October 1, 2000; 8(4): 335 - 337.
[PDF]


Home page
Am. J. Roentgenol.Home page
L. E. Philpotts, C. H. Lee, L. J. Horvath, R. C. Lange, D. Carter, and I. Tocino
Underestimation of Breast Cancer with II-Gauge Vacuum Suction Biopsy
Am. J. Roentgenol., October 1, 2000; 175(4): 1047 - 1050.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. L. Smathers
Advanced Breast Biopsy Instrumentation Device: Percentages of Lesion and Surrounding Tissue Removed
Am. J. Roentgenol., September 1, 2000; 175(3): 801 - 803.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman
Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium
Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. E. Reynolds
Core Needle Biopsy of Challenging Benign Breast Conditions: A Comprehensive Literature Review
Am. J. Roentgenol., May 1, 2000; 174(5): 1245 - 1250.
[Full Text] [PDF]


Home page
RadiologyHome page
R. J. Brenner
Lesions Entirely Removed during Stereotactic Biopsy: Preoperative Localization on the Basis of Mammographic Landmarks and Feasibility of Freehand Technique-Initial Experience
Radiology, February 1, 2000; 214(2): 585 - 590.
[Abstract] [Full Text]


Home page
Arch SurgHome page
J. M. Johnson, R. R. Dalton, S. M. Wester, J. Landercasper, and P. J. Lambert
Histological Correlation of Microcalcifications in Breast Biopsy Specimens
Arch Surg, July 1, 1999; 134(7): 712 - 716.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
J. E. Meyer, D. N. Smith, S. C. Lester, C. Kaelin, P. J. DiPiro, C. M. Denison, R. L. Christian, S. C. Harvey, D.-L. G. Selland, and S. M. Durfee
Large-Core Needle Biopsy of Nonpalpable Breast Lesions
JAMA, May 5, 1999; 281(17): 1638 - 1641.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Jackman, K. W. Nowels, J. Rodriguez-Soto, F. A. Marzoni Jr, S. I. Finkelstein, and M. J. Shepard
Stereotactic, Automated, Large-Core Needle Biopsy of Nonpalpable Breast Lesions: False-Negative and Histologic Underestimation Rates after Long-term Follow-up
Radiology, March 1, 1999; 210(3): 799 - 805.
[Abstract] [Full Text]


Home page
Arch SurgHome page
H. Seoudi, J. Mortier, R. Basile, and E. Curletti
Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions: Initial Experience With a Promising Technique
Arch Surg, April 1, 1998; 133(4): 366 - 372.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. A. Berg, C. L. Arnoldus, E. Teferra, and M. Bhargavan
Biopsy of Amorphous Breast Calcifications: Pathologic Outcome and Yield at Stereotactic Biopsy
Radiology, November 1, 2001; 221(2): 495 - 503.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. L. Mercado, D. Hamele-Bena, C. Singer, T. Koenigsberg, E. Pile-Spellman, H. Higgins, and S. J. Smith
Papillary Lesions of the Breast: Evaluation with Stereotactic Directional Vacuum-assisted Biopsy
Radiology, December 1, 2001; 221(3): 650 - 655.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.