Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Parker, S. H.
Right arrow Articles by Garver, P. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Parker, S. H.
Right arrow Articles by Garver, P. R.

Radiology, Vol 193, 359-364, Copyright © 1994 by Radiological Society of North America


ARTICLES

Percutaneous large-core breast biopsy: a multi-institutional study

SH Parker, F Burbank, RJ Jackman, CJ Aucreman, G Cardenosa, TM Cink, JL Coscia Jr, GW Eklund, WP Evans 3rd and PR Garver
Breast Diagnostic and Counseling Centre, Radiology Imaging Associates, Englewood, CO 80111.

PURPOSE: To assess the reliability and reproducibility of automated large-core breast biopsy. MATERIALS AND METHODS: A consortium of 20 institutions reported, in a standardized fashion, their core breast biopsy data. All biopsies were performed with "long-throw" (2.3-cm) automated core biopsy devices fitted with 14-gauge needles. Needle guidance was accomplished by means of either a dedicated, stereotaxic device, in which the patient lies in the prone position, or high- frequency electronically focused ultrasound equipment. RESULTS: The data in 6,152 lesions were gathered. Clinical or surgical follow-up was available in 3,765 lesions; 1,363 of these lesions were subsequently surgically excised, and the core histologic study showed cancer in 910 lesions, mammary intraepithelial neoplasia in 173 lesions, and benign disease in 280 lesions. In these 280 lesions, there were 15 false- negative core biopsies. CONCLUSION: The data show that percutaneous large-core breast biopsy is a reproducible and reliable alternative to surgical biopsy.


This article has been cited by other articles:


Home page
RadiologyHome page
G. Schueller, S. Jaromi, L. Ponhold, M. Fuchsjaeger, M. Memarsadeghi, M. Rudas, M. Weber, L. Liberman, and T. H. Helbich
US-guided 14-gauge Core-Needle Breast Biopsy: Results of a Validation Study in 1352 Cases
Radiology, August 1, 2008; 248(2): 406 - 413.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Pathol.Home page
E A Rakha and I O Ellis
An overview of assessment of prognostic and predictive factors in breast cancer needle core biopsy specimens
J. Clin. Pathol., December 1, 2007; 60(12): 1300 - 1306.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
C. M. B. Holloway, R. Saskin, M. Brackstone, and L. Paszat
Variation in the Use of Percutaneous Biopsy for Diagnosis of Breast Abnormalities in Ontario
Ann. Surg. Oncol., October 1, 2007; 14(10): 2932 - 2939.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
V. Sohn, Z. Arthurs, G. Herbert, J. Keylock, J. Perry, M. Eckert, D. Fellabaum, D. Smith, and T. Brown
Atypical Ductal Hyperplasia: Improved Accuracy with the 11-Gauge Vacuum-Assisted versus the 14-Gauge Core Biopsy Needle
Ann. Surg. Oncol., September 1, 2007; 14(9): 2497 - 2501.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. H. Youk, E.-K. Kim, M. J. Kim, J. Y. Lee, and K. K. Oh
Missed Breast Cancers at US-guided Core Needle Biopsy: How to Reduce Them
RadioGraphics, January 1, 2007; 27(1): 79 - 94.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Pathol.Home page
M F Dillon, C M Quinn, E W McDermott, A O'Doherty, N O'Higgins, and A D K Hill
Diagnostic accuracy of core biopsy for ductal carcinoma in situ and its implications for surgical practice.
J. Clin. Pathol., July 1, 2006; 59(7): 740 - 743.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. A. Berg
Sonographically Depicted Breast Clustered Microcysts: Is Follow-Up Appropriate?
Am. J. Roentgenol., October 1, 2005; 185(4): 952 - 959.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen
Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis?
Radiology, September 1, 2005; 236(3): 801 - 809.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman
Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy
Radiology, September 1, 2004; 232(3): 897 - 903.
[Abstract] [Full Text] [PDF]


Home page
JNCI J Natl Cancer InstHome page
G. D. Leonard and S. M. Swain
Ductal Carcinoma In Situ, Complexities and Challenges
J Natl Cancer Inst, June 16, 2004; 96(12): 906 - 920.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
R. M. Golub, C. L. Bennett, T. Stinson, L. Venta, and M. Morrow
Cost Minimization Study of Image-Guided Core Biopsy Versus Surgical Excisional Biopsy for Women With Abnormal Mammograms
J. Clin. Oncol., June 15, 2004; 22(12): 2430 - 2437.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
K. Kerlikowske, R. Smith-Bindman, B.-M. Ljung, and D. Grady
Evaluation of Abnormal Mammography Results and Palpable Breast Abnormalities
Ann Intern Med, August 19, 2003; 139(4): 274 - 284.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. J. Kirshenbaum, T. Voruganti, C. Overbeeke, M. D. Kirshenbaum, P. Patel, G. Kaplan, V. Maker, C. August, and R. P. Cavallino
Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions Using a Conventional Mammography Unit with an Add-On Device
Am. J. Roentgenol., August 1, 2003; 181(2): 527 - 531.
[Abstract] [Full Text] [PDF]


Home page
INT J SURG PATHOLHome page
S. Shousha
Issues in the Interpretation of Breast Core Biopsies
International Journal of Surgical Pathology, July 1, 2003; 11(3): 167 - 176.
[Abstract] [PDF]


Home page
Arch SurgHome page
D. J. Winchester, J. R. Bernstein, J. M. Jeske, M. H. Nicholson, E. A. Hahn, R. A. Goldschmidt, W. G. Watkin, S. F. Sener, M. B. Bilimoria, E. Barrera Jr, et al.
Upstaging of Atypical Ductal Hyperplasia After Vacuum-Assisted 11-Gauge Stereotactic Core Needle Biopsy
Arch Surg, June 1, 2003; 138(6): 619 - 623.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. E. March, B. F. Coughlin, R. B. Barham, R. A. Goulart, S. V. Klein, M. E. Bur, J. L. Frank, and G. Makari-Judson
Breast Masses: Removal of All US Evidence during Biopsy by Using a Handheld Vacuum-assisted Device--Initial Experience
Radiology, May 1, 2003; 227(2): 549 - 555.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. E. Fishman, C. Milikowski, R. Ramsinghani, M. V. Velasquez, and G. Aviram
US-guided Core-Needle Biopsy of the Breast: How Many Specimens Are Necessary?
Radiology, March 1, 2003; 226(3): 779 - 782.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. E. Philpotts, R. J. Hooley, and C. H. Lee
Comparison of Automated Versus Vacuum-Assisted Biopsy Methods for Sonographically Guided Core Biopsy of the Breast
Am. J. Roentgenol., February 1, 2003; 180(2): 347 - 351.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. M. Chen, B. G. Haffty, and C. H. Lee
Local Recurrence of Breast Cancer after Breast Conservation Therapy in Patients Examined by Means of Stereotactic Core-Needle Biopsy
Radiology, December 1, 2002; 225(3): 707 - 712.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
M. B. Mainiero, I. F. Gareen, C. E. Bird, W. Smith, C. Cobb, and B. Schepps
Preferential Use of Sonographically Guided Biopsy to Minimize Patient Discomfort and Procedure Time in a Percutaneous Image-Guided Breast Biopsy Program
J. Ultrasound Med., November 1, 2002; 21(11): 1221 - 1226.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Bazzocchi, G. E. Francescutti, C. Zuiani, C. Del Frate, and V. Londero
Breast Pseudoaneurysm in a Woman After Core Biopsy: Percutaneous Treatment with Alcohol
Am. J. Roentgenol., September 1, 2002; 179(3): 696 - 698.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Wunderbaldinger, G. Wolf, K. Turetschek, and T. H. Helbich
Comparison of Sitting Versus Prone Position for Stereotactic Large-Core Breast Biopsy in Surgically Proven Lesions
Am. J. Roentgenol., May 1, 2002; 178(5): 1221 - 1225.
[Abstract] [Full Text] [PDF]


Home page
JNCI J Natl Cancer InstHome page
L. Esserman, H. Cowley, C. Eberle, A. Kirkpatrick, S. Chang, K. Berbaum, and A. Gale
Improving the Accuracy of Mammography: Volume and Outcome Relationships
J Natl Cancer Inst, March 6, 2002; 94(5): 369 - 375.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
R. Bos, J. J.M. van der Hoeven, E. van der Wall, P. van der Groep, P. J. van Diest, E. F.I. Comans, U. Joshi, G. L. Semenza, O. S. Hoekstra, A. A. Lammertsma, et al.
Biologic Correlates of 18Fluorodeoxyglucose Uptake in Human Breast Cancer Measured by Positron Emission Tomography
J. Clin. Oncol., January 15, 2002; 20(2): 379 - 387.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Becker, D. Taves, L. McCurdy, G. Muscedere, S. Karlik, and S. Ward
Stereotactic Core Biopsy of Breast Microcalcifications: Comparison of Film Versus Digital Mammography, Both Using an Add-On Unit
Am. J. Roentgenol., December 1, 2001; 177(6): 1451 - 1457.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. A. Perez-Fuentes, I. R. Longobardi, V. F. Acosta, C. E. Marin, and L. Liberman
Sonographically Guided Directional Vacuum-Assisted Breast Biopsy: Preliminary Experience in Venezuela
Am. J. Roentgenol., December 1, 2001; 177(6): 1459 - 1463.
[Abstract] [Full Text] [PDF]


Home page
Arch SurgHome page
B. N. Fahy, R. J. Bold, P. D. Schneider, V. Khatri, and J. E. Goodnight Jr
Cost-Benefit Analysis of Biopsy Methods for Suspicious Mammographic Lesions
Arch Surg, September 1, 2001; 136(9): 990 - 995.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. R. Margolin, J. W. T. Leung, R. P. Jacobs, and S. R. Denny
Percutaneous Imaging-Guided Core Breast Biopsy: 5 Years' Experience in a Community Hospital
Am. J. Roentgenol., September 1, 2001; 177(3): 559 - 564.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. H. Parker, A. J. Klaus, P. J. Mc Wey, K. J. Schilling, T. E. Cupples, N. Duchesne, M. A. Guenin, and J. K. Harness
Sonographically Guided Directional Vacuum-Assisted Breast Biopsy Using a Handheld Device
Am. J. Roentgenol., August 1, 2001; 177(2): 405 - 408.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. K. Kuhl, N. Morakkabati, C. C. Leutner, A. Schmiedel, E. Wardelmann, and H. H. Schild
MR Imaging-guided Large-Core (14-Gauge) Needle Biopsy of Small Lesions Visible at Breast MR Imaging Alone
Radiology, July 1, 2001; 220(1): 31 - 39.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
R Warren and P Kessar
A method of coil localization for breast lesions seen only on MRI
Br. J. Radiol., June 1, 2001; 74(882): 548 - 551.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. D. Pisano, L. L. Fajardo, D. J. Caudry, N. Sneige, W. J. Frable, W. A. Berg, I. Tocino, S. J. Schnitt, J. L. Connolly, C. A. Gatsonis, et al.
Fine-Needle Aspiration Biopsy of Nonpalpable Breast Lesions in a Multicenter Clinical Trial: Results from the Radiologic Diagnostic Oncology Group V
Radiology, June 1, 2001; 219(3): 785 - 792.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
I. Vizcaíno, L. Gadea, L. Andreo, D. Salas, F. Ruiz-Perales, D. Cuevas, C. Herranz, and F. Bueno
Short-term Follow-up Results in 795 Nonpalpable Probably Benign Lesions Detected at Screening Mammography
Radiology, May 1, 2001; 219(2): 475 - 483.
[Abstract] [Full Text]


Home page
RadiologyHome page
R. J. Brenner, L. W. Bassett, L. L. Fajardo, D. D. Dershaw, W. P. Evans III, R. Hunt, C. Lee, I. Tocino, P. Fisher, M. McCombs, et al.
Stereotactic Core-Needle Breast Biopsy: A Multi-institutional Prospective Trial
Radiology, March 1, 2001; 218(3): 866 - 872.
[Abstract] [Full Text]


Home page
RadiologyHome page
P. C. Stomper, C. C. Stewart, and D. L. Stoler
Stereotactic Core Biopsy Breast and Blood Cell By-products: A Source of Material for Molecular Genetics Research-Initial Experience
Radiology, March 1, 2001; 218(3): 881 - 885.
[Abstract] [Full Text]


Home page
J. Clin. Pathol.Home page
A E K Ibrahim, A C Bateman, J M Theaker, J L Low, B Addis, P Tidbury, C Rubin, M Briley, and G T Royle
The role and histological classification of needle core biopsy in comparison with fine needle aspiration cytology in the preoperative assessment of impalpable breast lesions
J. Clin. Pathol., February 1, 2001; 54(2): 121 - 125.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. A. Berg, H. E. Mrose, and O. B. Ioffe
Atypical Lobular Hyperplasia or Lobular Carcinoma in Situ at Core-Needle Breast Biopsy
Radiology, February 1, 2001; 218(2): 503 - 509.
[Abstract] [Full Text]


Home page
J. Clin. Pathol.Home page
H Denley, S E Pinder, C W Elston, A H S Lee, and I O Ellis
Preoperative assessment of prognostic factors in breast cancer
J. Clin. Pathol., January 1, 2001; 54(1): 20 - 24.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. H. Lee, D. Carter, L. E. Philpotts, M. E. Couce, L. J. Horvath, R. C. Lange, and I. Tocino
Ductal Carcinoma in Situ Diagnosed with Stereotactic Core Needle Biopsy: Can Invasion Be Predicted?
Radiology, November 1, 2000; 217(2): 466 - 470.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
M. L. R. Darling, D. N. Smith, S. C. Lester, C. Kaelin, D.-L. G. Selland, C. M. Denison, P. J. DiPiro, D. I. Rose, E. Rhei, and J. E. Meyer
Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy: Results of Surgical Excision
Am. J. Roentgenol., November 1, 2000; 175(5): 1341 - 1346.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. E. Philpotts, N. A. Shaheen, K. S. Jain, D. Carter, and C. H. Lee
Uncommon High-Risk Lesions of the Breast Diagnosed at Stereotactic Core-Needle Biopsy: Clinical Importance
Radiology, September 1, 2000; 216(3): 831 - 837.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
G. J. Welle, M. Clark, S. Loos, D. Pauls, D. Warden, M. Sheffield, and C. Parsells
Stereotactic Breast Biopsy: Recumbent Biopsy Using Add-On Upright Equipment
Am. J. Roentgenol., July 1, 2000; 175(1): 59 - 63.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. J. Klaus, W. C. Klingensmith III, S. H. Parker, A. T. Stavros, J. D. Sutherland, and K. D. Aldrete
Comparative Value of 99mTc-Sestamibi Scintimammography and Sonography in the Diagnostic Workup of Breast Masses
Am. J. Roentgenol., June 1, 2000; 174(6): 1779 - 1783.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
L. Liberman
Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium
Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199.
[Full Text] [PDF]


Home page
RadiologyHome page
E. A. Sickles
Breast Imaging: From 1965 to the Present
Radiology, April 1, 2000; 215(1): 1 - 16.
[Abstract] [Full Text]


Home page
RadiologyHome page
R. J. Brenner
Lesions Entirely Removed during Stereotactic Biopsy: Preoperative Localization on the Basis of Mammographic Landmarks and Feasibility of Freehand Technique-Initial Experience
Radiology, February 1, 2000; 214(2): 585 - 590.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
M. K. Melotti and W. A. Berg
Core Needle Breast Biopsy in Patients Undergoing Anticoagulation Therapy: Preliminary Results
Am. J. Roentgenol., January 1, 2000; 174(1): 245 - 249.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. M. Hrung, C. P. Langlotz, S. G. Orel, K. R. Fox, M. D. Schnall, and J. S. Schwartz
Cost-effectiveness of MR Imaging and Core-Needle Biopsy in the Preoperative Work-up of Suspicious Breast Lesions
Radiology, October 1, 1999; 213(1): 39 - 49.
[Abstract] [Full Text]


Home page
Arch SurgHome page
J. M. Johnson, R. R. Dalton, S. M. Wester, J. Landercasper, and P. J. Lambert
Histological Correlation of Microcalcifications in Breast Biopsy Specimens
Arch Surg, July 1, 1999; 134(7): 712 - 716.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. H. Lee, L. E. Philpotts, L. J. Horvath, and I. Tocino
Follow-up of Breast Lesions Diagnosed as Benign with Stereotactic Core-Needle Biopsy: Frequency of Mammographic Change and False-Negative Rate
Radiology, July 1, 1999; 212(1): 189 - 194.
[Abstract] [Full Text]


Home page
Arch SurgHome page
H. Seoudi, J. Mortier, R. Basile, and E. Curletti
Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions: Initial Experience With a Promising Technique
Arch Surg, April 1, 1998; 133(4): 366 - 372.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.