Radiology, Vol 193, 359-364, Copyright © 1994 by Radiological Society of North America
ARTICLES |
SH Parker, F Burbank, RJ Jackman, CJ Aucreman, G Cardenosa, TM Cink, JL Coscia Jr, GW Eklund, WP Evans 3rd and PR Garver
Breast Diagnostic and Counseling Centre, Radiology Imaging Associates, Englewood, CO 80111.
PURPOSE: To assess the reliability and reproducibility of automated large-core breast biopsy. MATERIALS AND METHODS: A consortium of 20 institutions reported, in a standardized fashion, their core breast biopsy data. All biopsies were performed with "long-throw" (2.3-cm) automated core biopsy devices fitted with 14-gauge needles. Needle guidance was accomplished by means of either a dedicated, stereotaxic device, in which the patient lies in the prone position, or high- frequency electronically focused ultrasound equipment. RESULTS: The data in 6,152 lesions were gathered. Clinical or surgical follow-up was available in 3,765 lesions; 1,363 of these lesions were subsequently surgically excised, and the core histologic study showed cancer in 910 lesions, mammary intraepithelial neoplasia in 173 lesions, and benign disease in 280 lesions. In these 280 lesions, there were 15 false- negative core biopsies. CONCLUSION: The data show that percutaneous large-core breast biopsy is a reproducible and reliable alternative to surgical biopsy.
This article has been cited by other articles:
![]() |
G. Schueller, S. Jaromi, L. Ponhold, M. Fuchsjaeger, M. Memarsadeghi, M. Rudas, M. Weber, L. Liberman, and T. H. Helbich US-guided 14-gauge Core-Needle Breast Biopsy: Results of a Validation Study in 1352 Cases Radiology, August 1, 2008; 248(2): 406 - 413. [Abstract] [Full Text] [PDF] |
||||
![]() |
E A Rakha and I O Ellis An overview of assessment of prognostic and predictive factors in breast cancer needle core biopsy specimens J. Clin. Pathol., December 1, 2007; 60(12): 1300 - 1306. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. M. B. Holloway, R. Saskin, M. Brackstone, and L. Paszat Variation in the Use of Percutaneous Biopsy for Diagnosis of Breast Abnormalities in Ontario Ann. Surg. Oncol., October 1, 2007; 14(10): 2932 - 2939. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Sohn, Z. Arthurs, G. Herbert, J. Keylock, J. Perry, M. Eckert, D. Fellabaum, D. Smith, and T. Brown Atypical Ductal Hyperplasia: Improved Accuracy with the 11-Gauge Vacuum-Assisted versus the 14-Gauge Core Biopsy Needle Ann. Surg. Oncol., September 1, 2007; 14(9): 2497 - 2501. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Youk, E.-K. Kim, M. J. Kim, J. Y. Lee, and K. K. Oh Missed Breast Cancers at US-guided Core Needle Biopsy: How to Reduce Them RadioGraphics, January 1, 2007; 27(1): 79 - 94. [Abstract] [Full Text] [PDF] |
||||
![]() |
M F Dillon, C M Quinn, E W McDermott, A O'Doherty, N O'Higgins, and A D K Hill Diagnostic accuracy of core biopsy for ductal carcinoma in situ and its implications for surgical practice. J. Clin. Pathol., July 1, 2006; 59(7): 740 - 743. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. A. Berg Sonographically Depicted Breast Clustered Microcysts: Is Follow-Up Appropriate? Am. J. Roentgenol., October 1, 2005; 185(4): 952 - 959. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis? Radiology, September 1, 2005; 236(3): 801 - 809. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy Radiology, September 1, 2004; 232(3): 897 - 903. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. D. Leonard and S. M. Swain Ductal Carcinoma In Situ, Complexities and Challenges J Natl Cancer Inst, June 16, 2004; 96(12): 906 - 920. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Golub, C. L. Bennett, T. Stinson, L. Venta, and M. Morrow Cost Minimization Study of Image-Guided Core Biopsy Versus Surgical Excisional Biopsy for Women With Abnormal Mammograms J. Clin. Oncol., June 15, 2004; 22(12): 2430 - 2437. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Kerlikowske, R. Smith-Bindman, B.-M. Ljung, and D. Grady Evaluation of Abnormal Mammography Results and Palpable Breast Abnormalities Ann Intern Med, August 19, 2003; 139(4): 274 - 284. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Kirshenbaum, T. Voruganti, C. Overbeeke, M. D. Kirshenbaum, P. Patel, G. Kaplan, V. Maker, C. August, and R. P. Cavallino Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions Using a Conventional Mammography Unit with an Add-On Device Am. J. Roentgenol., August 1, 2003; 181(2): 527 - 531. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Shousha Issues in the Interpretation of Breast Core Biopsies International Journal of Surgical Pathology, July 1, 2003; 11(3): 167 - 176. [Abstract] [PDF] |
||||
![]() |
D. J. Winchester, J. R. Bernstein, J. M. Jeske, M. H. Nicholson, E. A. Hahn, R. A. Goldschmidt, W. G. Watkin, S. F. Sener, M. B. Bilimoria, E. Barrera Jr, et al. Upstaging of Atypical Ductal Hyperplasia After Vacuum-Assisted 11-Gauge Stereotactic Core Needle Biopsy Arch Surg, June 1, 2003; 138(6): 619 - 623. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. E. March, B. F. Coughlin, R. B. Barham, R. A. Goulart, S. V. Klein, M. E. Bur, J. L. Frank, and G. Makari-Judson Breast Masses: Removal of All US Evidence during Biopsy by Using a Handheld Vacuum-assisted Device--Initial Experience Radiology, May 1, 2003; 227(2): 549 - 555. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Fishman, C. Milikowski, R. Ramsinghani, M. V. Velasquez, and G. Aviram US-guided Core-Needle Biopsy of the Breast: How Many Specimens Are Necessary? Radiology, March 1, 2003; 226(3): 779 - 782. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. Philpotts, R. J. Hooley, and C. H. Lee Comparison of Automated Versus Vacuum-Assisted Biopsy Methods for Sonographically Guided Core Biopsy of the Breast Am. J. Roentgenol., February 1, 2003; 180(2): 347 - 351. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Chen, B. G. Haffty, and C. H. Lee Local Recurrence of Breast Cancer after Breast Conservation Therapy in Patients Examined by Means of Stereotactic Core-Needle Biopsy Radiology, December 1, 2002; 225(3): 707 - 712. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Mainiero, I. F. Gareen, C. E. Bird, W. Smith, C. Cobb, and B. Schepps Preferential Use of Sonographically Guided Biopsy to Minimize Patient Discomfort and Procedure Time in a Percutaneous Image-Guided Breast Biopsy Program J. Ultrasound Med., November 1, 2002; 21(11): 1221 - 1226. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Bazzocchi, G. E. Francescutti, C. Zuiani, C. Del Frate, and V. Londero Breast Pseudoaneurysm in a Woman After Core Biopsy: Percutaneous Treatment with Alcohol Am. J. Roentgenol., September 1, 2002; 179(3): 696 - 698. [Full Text] [PDF] |
||||
![]() |
P. Wunderbaldinger, G. Wolf, K. Turetschek, and T. H. Helbich Comparison of Sitting Versus Prone Position for Stereotactic Large-Core Breast Biopsy in Surgically Proven Lesions Am. J. Roentgenol., May 1, 2002; 178(5): 1221 - 1225. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Esserman, H. Cowley, C. Eberle, A. Kirkpatrick, S. Chang, K. Berbaum, and A. Gale Improving the Accuracy of Mammography: Volume and Outcome Relationships J Natl Cancer Inst, March 6, 2002; 94(5): 369 - 375. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Bos, J. J.M. van der Hoeven, E. van der Wall, P. van der Groep, P. J. van Diest, E. F.I. Comans, U. Joshi, G. L. Semenza, O. S. Hoekstra, A. A. Lammertsma, et al. Biologic Correlates of 18Fluorodeoxyglucose Uptake in Human Breast Cancer Measured by Positron Emission Tomography J. Clin. Oncol., January 15, 2002; 20(2): 379 - 387. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Becker, D. Taves, L. McCurdy, G. Muscedere, S. Karlik, and S. Ward Stereotactic Core Biopsy of Breast Microcalcifications: Comparison of Film Versus Digital Mammography, Both Using an Add-On Unit Am. J. Roentgenol., December 1, 2001; 177(6): 1451 - 1457. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Perez-Fuentes, I. R. Longobardi, V. F. Acosta, C. E. Marin, and L. Liberman Sonographically Guided Directional Vacuum-Assisted Breast Biopsy: Preliminary Experience in Venezuela Am. J. Roentgenol., December 1, 2001; 177(6): 1459 - 1463. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. N. Fahy, R. J. Bold, P. D. Schneider, V. Khatri, and J. E. Goodnight Jr Cost-Benefit Analysis of Biopsy Methods for Suspicious Mammographic Lesions Arch Surg, September 1, 2001; 136(9): 990 - 995. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. R. Margolin, J. W. T. Leung, R. P. Jacobs, and S. R. Denny Percutaneous Imaging-Guided Core Breast Biopsy: 5 Years' Experience in a Community Hospital Am. J. Roentgenol., September 1, 2001; 177(3): 559 - 564. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Parker, A. J. Klaus, P. J. Mc Wey, K. J. Schilling, T. E. Cupples, N. Duchesne, M. A. Guenin, and J. K. Harness Sonographically Guided Directional Vacuum-Assisted Breast Biopsy Using a Handheld Device Am. J. Roentgenol., August 1, 2001; 177(2): 405 - 408. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. K. Kuhl, N. Morakkabati, C. C. Leutner, A. Schmiedel, E. Wardelmann, and H. H. Schild MR Imaging-guided Large-Core (14-Gauge) Needle Biopsy of Small Lesions Visible at Breast MR Imaging Alone Radiology, July 1, 2001; 220(1): 31 - 39. [Abstract] [Full Text] [PDF] |
||||
![]() |
R Warren and P Kessar A method of coil localization for breast lesions seen only on MRI Br. J. Radiol., June 1, 2001; 74(882): 548 - 551. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. D. Pisano, L. L. Fajardo, D. J. Caudry, N. Sneige, W. J. Frable, W. A. Berg, I. Tocino, S. J. Schnitt, J. L. Connolly, C. A. Gatsonis, et al. Fine-Needle Aspiration Biopsy of Nonpalpable Breast Lesions in a Multicenter Clinical Trial: Results from the Radiologic Diagnostic Oncology Group V Radiology, June 1, 2001; 219(3): 785 - 792. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Vizcaíno, L. Gadea, L. Andreo, D. Salas, F. Ruiz-Perales, D. Cuevas, C. Herranz, and F. Bueno Short-term Follow-up Results in 795 Nonpalpable Probably Benign Lesions Detected at Screening Mammography Radiology, May 1, 2001; 219(2): 475 - 483. [Abstract] [Full Text] |
||||
![]() |
R. J. Brenner, L. W. Bassett, L. L. Fajardo, D. D. Dershaw, W. P. Evans III, R. Hunt, C. Lee, I. Tocino, P. Fisher, M. McCombs, et al. Stereotactic Core-Needle Breast Biopsy: A Multi-institutional Prospective Trial Radiology, March 1, 2001; 218(3): 866 - 872. [Abstract] [Full Text] |
||||
![]() |
P. C. Stomper, C. C. Stewart, and D. L. Stoler Stereotactic Core Biopsy Breast and Blood Cell By-products: A Source of Material for Molecular Genetics Research-Initial Experience Radiology, March 1, 2001; 218(3): 881 - 885. [Abstract] [Full Text] |
||||
![]() |
A E K Ibrahim, A C Bateman, J M Theaker, J L Low, B Addis, P Tidbury, C Rubin, M Briley, and G T Royle The role and histological classification of needle core biopsy in comparison with fine needle aspiration cytology in the preoperative assessment of impalpable breast lesions J. Clin. Pathol., February 1, 2001; 54(2): 121 - 125. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. A. Berg, H. E. Mrose, and O. B. Ioffe Atypical Lobular Hyperplasia or Lobular Carcinoma in Situ at Core-Needle Breast Biopsy Radiology, February 1, 2001; 218(2): 503 - 509. [Abstract] [Full Text] |
||||
![]() |
H Denley, S E Pinder, C W Elston, A H S Lee, and I O Ellis Preoperative assessment of prognostic factors in breast cancer J. Clin. Pathol., January 1, 2001; 54(1): 20 - 24. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. H. Lee, D. Carter, L. E. Philpotts, M. E. Couce, L. J. Horvath, R. C. Lange, and I. Tocino Ductal Carcinoma in Situ Diagnosed with Stereotactic Core Needle Biopsy: Can Invasion Be Predicted? Radiology, November 1, 2000; 217(2): 466 - 470. [Abstract] [Full Text] |
||||
![]() |
M. L. R. Darling, D. N. Smith, S. C. Lester, C. Kaelin, D.-L. G. Selland, C. M. Denison, P. J. DiPiro, D. I. Rose, E. Rhei, and J. E. Meyer Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy: Results of Surgical Excision Am. J. Roentgenol., November 1, 2000; 175(5): 1341 - 1346. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. Philpotts, N. A. Shaheen, K. S. Jain, D. Carter, and C. H. Lee Uncommon High-Risk Lesions of the Breast Diagnosed at Stereotactic Core-Needle Biopsy: Clinical Importance Radiology, September 1, 2000; 216(3): 831 - 837. [Abstract] [Full Text] |
||||
![]() |
G. J. Welle, M. Clark, S. Loos, D. Pauls, D. Warden, M. Sheffield, and C. Parsells Stereotactic Breast Biopsy: Recumbent Biopsy Using Add-On Upright Equipment Am. J. Roentgenol., July 1, 2000; 175(1): 59 - 63. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Klaus, W. C. Klingensmith III, S. H. Parker, A. T. Stavros, J. D. Sutherland, and K. D. Aldrete Comparative Value of 99mTc-Sestamibi Scintimammography and Sonography in the Diagnostic Workup of Breast Masses Am. J. Roentgenol., June 1, 2000; 174(6): 1779 - 1783. [Abstract] [Full Text] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
E. A. Sickles Breast Imaging: From 1965 to the Present Radiology, April 1, 2000; 215(1): 1 - 16. [Abstract] [Full Text] |
||||
![]() |
R. J. Brenner Lesions Entirely Removed during Stereotactic Biopsy: Preoperative Localization on the Basis of Mammographic Landmarks and Feasibility of Freehand Technique-Initial Experience Radiology, February 1, 2000; 214(2): 585 - 590. [Abstract] [Full Text] |
||||
![]() |
M. K. Melotti and W. A. Berg Core Needle Breast Biopsy in Patients Undergoing Anticoagulation Therapy: Preliminary Results Am. J. Roentgenol., January 1, 2000; 174(1): 245 - 249. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Hrung, C. P. Langlotz, S. G. Orel, K. R. Fox, M. D. Schnall, and J. S. Schwartz Cost-effectiveness of MR Imaging and Core-Needle Biopsy in the Preoperative Work-up of Suspicious Breast Lesions Radiology, October 1, 1999; 213(1): 39 - 49. [Abstract] [Full Text] |
||||
![]() |
J. M. Johnson, R. R. Dalton, S. M. Wester, J. Landercasper, and P. J. Lambert Histological Correlation of Microcalcifications in Breast Biopsy Specimens Arch Surg, July 1, 1999; 134(7): 712 - 716. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. H. Lee, L. E. Philpotts, L. J. Horvath, and I. Tocino Follow-up of Breast Lesions Diagnosed as Benign with Stereotactic Core-Needle Biopsy: Frequency of Mammographic Change and False-Negative Rate Radiology, July 1, 1999; 212(1): 189 - 194. [Abstract] [Full Text] |
||||
![]() |
H. Seoudi, J. Mortier, R. Basile, and E. Curletti Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions: Initial Experience With a Promising Technique Arch Surg, April 1, 1998; 133(4): 366 - 372. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |