Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Alagappan, R.
Right arrow Articles by McGahan, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Alagappan, R.
Right arrow Articles by McGahan, J. P.

Radiology, Vol 193, 405-408, Copyright © 1994 by Radiological Society of North America


ARTICLES

Distal lateral ventricular atrium: reevaluation of normal range

R Alagappan, PD Browning, A Laorr and JP McGahan
Department of Radiology, University of California Davis Medical Center, Sacramento 95817.

PURPOSE: To reassess the mean size of the lateral cerebral ventricular atrium in the fetus. MATERIALS AND METHODS: Measurements were obtained from axial ultrasound (US) images of 500 fetuses by using the standard criteria, and they were reviewed for consistency. Eleven fetuses had ventricular atrial measurements of 10 mm or more, and they were also followed up. Postnatal evaluation consisted of US examinations of the head in three patients and clinical examination of all 11 patients. RESULTS: The mean size of the ventricular atrium was 6.6 mm with a standard deviation (SD) of 1.4 mm. However, the mean plus 2.5 SD would yield an upper normal limit of 10.1 mm. Findings at the postnatal examinations of the 11 fetuses with isolated lateral ventriculomegaly (three with measurements of 13 mm or less and eight with measurements at 10 mm) were normal. CONCLUSION: Use of 10 mm (mean from this study plus 2.5 SD) as the upper limit of normal for the ventricular atrial measurement should be continued. Measurements of 10 mm or above should prompt a careful search for associated fetal abnormalities and consideration of amniocentesis.


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
R. Bronsteen, W. Lee, I. Vettraino, M. Balasubramaniam, and C. Comstock
Isolated choroid plexus separation on second-trimester sonography: natural history and postnatal importance.
J. Ultrasound Med., March 1, 2006; 25(3): 343 - 347.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
D. V. Valsky, L. Ben-Sira, S. Porat, N. Yanai, A. Lewin, M. Nadjari, J. M. Gomori, and S. Yagel
The Role of Magnetic Resonance Imaging in the Evaluation of Isolated Mild Ventriculomegaly
J. Ultrasound Med., April 1, 2004; 23(4): 519 - 523.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
B. Almog, R. Gamzu, R. Achiron, O. Fainaru, and Y. Zalel
Fetal Lateral Ventricular Width: What Should Be Its Upper Limit? A Prospective Cohort Study and Reanalysis of the Current and Previous Data
J. Ultrasound Med., January 1, 2003; 22(1): 39 - 43.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.