Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schlueter, F. J.
Right arrow Articles by Vannier, M. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schlueter, F. J.
Right arrow Articles by Vannier, M. W.

Radiology, Vol 193, 413-418, Copyright © 1994 by Radiological Society of North America


ARTICLES

Longitudinal image deblurring in spiral CT

FJ Schlueter, G Wang, PS Hsieh, JA Brink, DM Balfe and MW Vannier
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, MO 63110.

PURPOSE: To assess the feasibility of digital deconvolution techniques to improve longitudinal resolution of spiral computed tomography (CT) multiplanar reformations and evaluate how technical factors in deconvolution affect longitudinal resolution, noise, and edge ringing. MATERIALS AND METHODS: Longitudinal line spread function (LSF) of the system was estimated from longitudinal reformations of transaxial spiral CT images of a step test phantom. By using the estimated LSF, longitudinal reformations of the phantom and three clinical spiral CT studies were deconvolved by the methods of Wiener filtering and constrained iterative deconvolution. Edge ringing and image noise were quantified for Wiener filtering and constrained iterative deconvolution. RESULTS: Longitudinal reformations were substantially deblurred and resolution improved after deconvolution. Anatomic boundaries in clinical images were more clearly delineated after restoration. The methods of Wiener deconvolution and constrained iterative deconvolution improved the sharpness of the phantom step boundary at the expense of increased edge ringing and image noise. CONCLUSION: In longitudinal spiral CT reformations, blurring along the longitudinal axis can be reduced by Wiener filtering or constrained iterative deconvolution.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
O. I. Saba, E. A. Hoffman, and J. M. Reinhardt
Maximizing quantitative accuracy of lung airway lumen and wall measures obtained from X-ray CT imaging
J Appl Physiol, September 1, 2003; 95(3): 1063 - 1075.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. R. Whiting, E. G. McFarland, and J. A. Brink
Influence of Image Acquisition Parameters on CT Artifacts and Polyp Depiction in Spiral CT Colonography: In Vitro Evaluation
Radiology, October 1, 2000; 217(1): 165 - 172.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.