Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chambers, T. P.
Right arrow Articles by Lush, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chambers, T. P.
Right arrow Articles by Lush, R. M.

Radiology, Vol 193, 513-517, Copyright © 1994 by Radiological Society of North America


ARTICLES

Hepatic CT enhancement. Part I. Alterations in the volume of contrast material within the same patients

TP Chambers, RL Baron and RM Lush
Department of Radiology, University of Pittsburgh Medical Center, PA 15213-2582.

PURPOSE: To evaluate the effects of alterations in the volume of contrast material on liver enhancement. MATERIALS AND METHODS: Thirty patients underwent repeat computed tomographic (CT) examinations within 6 months, the first with either 100, 150, or 180 mL of nonionic contrast material (2 mL/sec). In the second, only volume was altered. Liver attenuation was measured before and after contrast material administration, and enhancement was calculated for each image. Comparisons were made only within the same patients. RESULTS: Mean liver enhancement was greater with 150 mL compared with 100 mL beyond 55 seconds after injection. Mean peak enhancement was greater by 21 HU with 150 mL; mean time to peak enhancement was longer by 14 seconds. Mean liver enhancement was greater with 180 mL compared with 150 mL at all intervals beyond 80 seconds. Mean peak enhancement was greater by 22 HU; mean time to peak liver enhancement was longer by 24 seconds. CONCLUSION: Alterations in contrast material volume have substantial impact on liver enhancement and potentially tumor conspicuity. The optimal window of time for liver imaging after contrast material injection varies with the volume administered.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard
Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity
Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Furuta, K. Ito, T. Fujita, S. Koike, A. Shimizu, and N. Matsunaga
Hepatic Enhancement in Multiphasic Contrast-Enhanced MDCT: Comparison of High- and Low-Iodine-Concentration Contrast Medium in Same Patients with Chronic Liver Disease
Am. J. Roentgenol., July 1, 2004; 183(1): 157 - 162.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Imbriaco, A. J. Megibow, L. Camera, L. Pace, P. P. Mainenti, M. Romano, G. Selva, and M. Salvatore
Dual-Phase Versus Single-Phase Helical CT to Detect and Assess Resectability of Pancreatic Carcinoma
Am. J. Roentgenol., June 1, 2002; 178(6): 1473 - 1479.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Kim, M. P. Federle, R. L. Baron, M. S. Peterson, and Y. Kawamori
Discrimination of Small Hepatic Hemangiomas from Hypervascular Malignant Tumors Smaller than 3 cm with Three-Phase Helical CT
Radiology, June 1, 2001; 219(3): 699 - 706.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. R. Herts, C. M. O'Malley, S. L. Wirth, M. L. Lieber, and B. Pohlman
Power Injection of Contrast Media Using Central Venous Catheters: Feasibility, Safety, and Efficacy
Am. J. Roentgenol., February 1, 2001; 176(2): 447 - 453.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Yamashita, Y. Komohara, M. Takahashi, M. Uchida, N. Hayabuchi, T. Shimizu, and I. Narabayashi
Abdominal Helical CT: Evaluation of Optimal Doses of Intravenous Contrast Material-A Prospective Randomized Study
Radiology, September 1, 2000; 216(3): 718 - 723.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
B. S. Kuszyk, D. A. Bluemke, M. A. Choti, K. M. Horton, C. A. Magee, and E. K. Fishman
Contrast-Enhanced CT of Small Hypovascular Hepatic Tumors: Effect of Lesion Enhancement on Conspicuity in Rabbits
Am. J. Roentgenol., February 1, 2000; 174(2): 471 - 0.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Kim, T. Murakami, S. Takahashi, A. Okada, M. Hori, Y. Narumi, and H. Nakamura
Pancreatic CT Imaging: Effects of Different Injection Rates and Doses of Contrast Material
Radiology, July 1, 1999; 212(1): 219 - 225.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1994 by the Radiological Society of North America.