Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kazerooni, E. A.
Right arrow Articles by Gross, B. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kazerooni, E. A.
Right arrow Articles by Gross, B. H.

Radiology, Vol 194, 209-212, Copyright © 1995 by Radiological Society of North America


ARTICLES

Transplanted lungs: nodules following transbronchial biopsy

EA Kazerooni, PN Cascade and BH Gross
Department of Radiology, University of Michigan Hospital, Ann Arbor 48109-0326.

PURPOSE: To determine how often nodules occur in lung allografts due to transbronchial biopsy and the temporal relationship between the development of these lesions and biopsy. MATERIALS AND METHODS: During 2 years, 141 computed tomographic (CT) studies and 324 transbronchial biopsies were performed in 40 patients who had undergone lung transplantation. CT images and chest radiographs were retrospectively evaluated for evidence of lung injury. RESULTS: Thirteen CT studies of 12 patients revealed transbronchial biopsy injury. Seven cavitary and nine solid nodules were seen a mean of 8.8 and 18.6 days after biopsy, respectively. Two nodules were detected prospectively on radiographs; seven, retrospectively. In two patients, nodules not seen on chest radiographs obtained immediately after biopsy were seen on radiographs obtained 8 and 12 days later. Fifteen lesions resolved. One lesion left a linear scar. CONCLUSION: Nodules that represent transbronchial biopsy lung injury are seen on CT images up to 1 month after biopsy and may not be evident on chest radiographs obtained immediately after biopsy.


This article has been cited by other articles:


Home page
RadioGraphicsHome page
M. S. Krishnam, R. D. Suh, A. Tomasian, J. G. Goldin, C. Lai, K. Brown, P. Batra, and D. R. Aberle
Postoperative Complications of Lung Transplantation: Radiologic Findings along a Time Continuum
RadioGraphics, July 1, 2007; 27(4): 957 - 974.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. M. Park, J. M. Goo, H. J. Lee, C. H. Lee, E. J. Chun, and J.-G. Im
Nodular Ground-Glass Opacity at Thin-Section CT: Histologic Correlation and Evaluation of Change at Follow-up
RadioGraphics, March 1, 2007; 27(2): 391 - 408.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. S. Pinto
The CT Halo Sign
Radiology, January 1, 2004; 230(1): 109 - 110.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.