Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Li, K. C.
Right arrow Articles by Song, C. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Li, K. C.
Right arrow Articles by Song, C. K.

Radiology, Vol 194, 321-325, Copyright © 1995 by Radiological Society of North America


ARTICLES

Oxygen saturation of blood in the superior mesenteric vein: in vivo verification of MR imaging measurements in a canine model. Work in progress

KC Li, GA Wright, LR Pelc, RL Dalman, JH Brittain, H Wegmueller, DT Lin and CK Song
Department of Radiology, Stanford University School of Medicine, CA 94305.

PURPOSE: To evaluate the accuracy of magnetic resonance (MR) imaging in estimating oxygen saturation of blood (%HbO2) in the superior mesenteric vein (SMV) of a canine model in vivo. MATERIALS AND METHODS: MR imaging was used to measure the T2 of blood in samples obtained via a catheter placed in the SMV in seven mongrel dogs. %HbO2 was measured with a reflectance oximeter. These measurements were obtained at the resting state, during superior mesenteric artery occlusion, and after reperfusion. MR imaging and oximeter measurements were then compared by using linear regression analysis. RESULTS: Refocusing intervals (tau 180) of 12 and 24 msec were used for 17 and 18 %HbO2 measurements with MR imaging, respectively. With tau 180 of 12 msec, there was an excellent correlation between MR imaging measurements and oximeter measurements (r = .969). The intercept was 5.3% and the slope was 0.959. With tau 180 of 24 msec, r = .953, the intercept was 15.4%, and the slope was 0.817. CONCLUSION: Estimates of %HbO2 in the SMV with MR imaging are accurate in the range of most clinical interest.


This article has been cited by other articles:


Home page
JNMHome page
K. A. Krohn, J. M. Link, and R. P. Mason
Molecular Imaging of Hypoxia
J. Nucl. Med., June 1, 2008; 49(Suppl_2): 129S - 148S.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. E. Gold, E. Han, J. Stainsby, G. Wright, J. Brittain, and C. Beaulieu
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Am. J. Roentgenol., August 1, 2004; 183(2): 343 - 351.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. S. Bradbury, P. V. Kavanagh, R. E. Bechtold, M. Y. Chen, D. J. Ott, J. D. Regan, and T. M. Weber
Mesenteric Venous Thrombosis: Diagnosis and Noninvasive Imaging
RadioGraphics, May 1, 2002; 22(3): 527 - 541.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
B. Driessen, J. S. Jahr, F. Lurie, S. M. Griffey, and R. A. Gunther
Effects of haemoglobin-based oxygen carrier Hemoglobin glutamer-200 (bovine) on intestinal perfusion and oxygenation in a canine hypovolaemia model
Br. J. Anaesth., May 1, 2001; 86(5): 683 - 692.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.