PURPOSE: To assess the accuracy with which stereotaxic core biopsy of breast carcinoma predicts the presence of invasion. MATERIALS AND METHODS: Stereotaxic core biopsy was performed in 63 breast carcinomas in 59 patients in the prone position. All patients subsequently underwent surgery. Histopathologic results of stereotaxic core biopsy and surgery were correlated. RESULTS: Results of stereotaxic core biopsy and surgery were concordant in 58 (92%) of the 63 cases, yielding invasive carcinoma in 46 cases and ductal carcinoma in situ (DCIS) in 12 cases. Results were discordant in five cases (8%), including three cases for which stereotaxic core biopsy results indicated DCIS but surgery yielded invasive ductal carcinoma. The positive predictive value of stereotaxic core biopsy for the presence of invasion was 98% (47 of 48 cases) and the negative predictive value was 80% (12 of 15 cases). CONCLUSION: Stereotaxic core biopsy of breast carcinoma can help confirm invasion with high accuracy but cannot reliably indicate the absence of tumor invasion when only DCIS is found.
This article has been cited by other articles:
![]() |
G. Arpino, R. Laucirica, and R. M. Elledge Premalignant and In Situ Breast Disease: Biology and Clinical Implications Ann Intern Med, September 20, 2005; 143(6): 446 - 457. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis? Radiology, September 1, 2005; 236(3): 801 - 809. [Abstract] [Full Text] [PDF] |
||||
![]() |
I O Ellis, S Humphreys, M Michell, S E Pinder, C A Wells, and H D Zakhour Best Practice No 179: Guidelines for breast needle core biopsy handling and reporting in breast screening assessment J. Clin. Pathol., September 1, 2004; 57(9): 897 - 902. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Chen, B. G. Haffty, and C. H. Lee Local Recurrence of Breast Cancer after Breast Conservation Therapy in Patients Examined by Means of Stereotactic Core-Needle Biopsy Radiology, December 1, 2002; 225(3): 707 - 712. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, S. L. Goodstine, D. D. Dershaw, E. A. Morris, L. R. LaTrenta, A. F. Abramson, and K. J. V. Zee One Operation After Percutaneous Diagnosis of Nonpalpable Breast Cancer: Frequency and Associated Factors Am. J. Roentgenol., March 1, 2002; 178(3): 673 - 679. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Parker, A. J. Klaus, P. J. Mc Wey, K. J. Schilling, T. E. Cupples, N. Duchesne, M. A. Guenin, and J. K. Harness Sonographically Guided Directional Vacuum-Assisted Breast Biopsy Using a Handheld Device Am. J. Roentgenol., August 1, 2001; 177(2): 405 - 408. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Brenner, L. W. Bassett, L. L. Fajardo, D. D. Dershaw, W. P. Evans III, R. Hunt, C. Lee, I. Tocino, P. Fisher, M. McCombs, et al. Stereotactic Core-Needle Breast Biopsy: A Multi-institutional Prospective Trial Radiology, March 1, 2001; 218(3): 866 - 872. [Abstract] [Full Text] |
||||
![]() |
R. J. Jackman, F. Burbank, S. H. Parker, W. P. Evans III, M. C. Lechner, T. R. Richardson, A. A. Smid, H. B. Borofsky, C. H. Lee, H. M. Goldstein, et al. Stereotactic Breast Biopsy of Nonpalpable Lesions: Determinants of Ductal Carcinoma in Situ Underestimation Rates Radiology, February 1, 2001; 218(2): 497 - 502. [Abstract] [Full Text] |
||||
![]() |
C. H. Lee, D. Carter, L. E. Philpotts, M. E. Couce, L. J. Horvath, R. C. Lange, and I. Tocino Ductal Carcinoma in Situ Diagnosed with Stereotactic Core Needle Biopsy: Can Invasion Be Predicted? Radiology, November 1, 2000; 217(2): 466 - 470. [Abstract] [Full Text] |
||||
![]() |
M. L. R. Darling, D. N. Smith, S. C. Lester, C. Kaelin, D.-L. G. Selland, C. M. Denison, P. J. DiPiro, D. I. Rose, E. Rhei, and J. E. Meyer Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy: Results of Surgical Excision Am. J. Roentgenol., November 1, 2000; 175(5): 1341 - 1346. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. Philpotts, C. H. Lee, L. J. Horvath, R. C. Lange, D. Carter, and I. Tocino Underestimation of Breast Cancer with II-Gauge Vacuum Suction Biopsy Am. J. Roentgenol., October 1, 2000; 175(4): 1047 - 1050. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
R. J. Jackman, K. W. Nowels, J. Rodriguez-Soto, F. A. Marzoni Jr, S. I. Finkelstein, and M. J. Shepard Stereotactic, Automated, Large-Core Needle Biopsy of Nonpalpable Breast Lesions: False-Negative and Histologic Underestimation Rates after Long-term Follow-up Radiology, March 1, 1999; 210(3): 799 - 805. [Abstract] [Full Text] |
||||
![]() |
H. Seoudi, J. Mortier, R. Basile, and E. Curletti Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions: Initial Experience With a Promising Technique Arch Surg, April 1, 1998; 133(4): 366 - 372. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |