Radiology, Vol 194, 425-429, Copyright © 1995 by Radiological Society of North America
ARTICLES |
DJ Macfarlane, L Cotton, RJ Ackermann, H Minn, EP Ficaro, PD Shreve and RL Wahl
Division of Nuclear Medicine, University of Michigan Hospitals 48109- 0028.
PURPOSE: In patients with cancer, performance was assessed of a commercially available triple-head gamma camera fitted with ultra-high energy parallel-hole collimators performing single photon emission computed tomography (SPECT) with 2-[fluorine-18]fluoro-2-deoxy-D- glucose (FDG). Results were compared with those of positron emission tomography (PET) with FDG. MATERIALS AND METHODS: Performance characteristics were first determined in phantom studies for FDG PET and triple-head gamma camera SPECT systems. In 13 patients with malignancies, FDG PET was followed by SPECT of the same region, and imaging results were independently assessed. RESULTS: Sensitivity of the PET and SPECT systems was 58.3 counts/MBq/min and 4.5 counts/MBq/min, respectively. Reconstructed spatial resolution was approximately 7 mm for PET and 20 mm for SPECT. All known cancer foci were detected at PET. SPECT depicted 11 of the 22 lesions detected at PET, but only five of the 14 lesions less than 3 cm in diameter. CONCLUSION: FDG SPECT performed with a specially collimated triple-head gamma camera depicted some cancers but had an unacceptably low sensitivity compared with PET for lesions less than 3 cm in diameter. PET is preferable for detecting small cancers.
This article has been cited by other articles:
![]() |
O. Israel, M. Mor, D. Gaitini, Z. Keidar, L. Guralnik, A. Engel, A. Frenkel, R. Bar-Shalom, and A. Kuten Combined Functional and Structural Evaluation of Cancer Patients with a Hybrid Camera-Based PET/CT System Using 18F-FDG J. Nucl. Med., September 1, 2002; 43(9): 1129 - 1136. [Abstract] [Full Text] [PDF] |
||||
![]() |
H Zhang, M Tian, N Oriuchi, T Higuchi, S Tanada, and K Endo Oncological diagnosis using positron coincidence gamma camera with fluorodeoxyglucose in comparison with dedicated PET Br. J. Radiol., May 31, 2002; 75(893): 409 - 416. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Shiga, E. Tsukamoto, K. Nakada, K. Morita, T. Kato, M. Mabuchi, K. Yoshinaga, C. Katoh, Y. Kuge, and N. Tamaki Comparison of 18F-FDG, 131I-Na, and 201Tl in Diagnosis of Recurrent or Metastatic Thyroid Carcinoma J. Nucl. Med., March 1, 2001; 42(3): 414 - 419. [Abstract] [Full Text] |
||||
![]() |
M. K. Gould, C. C. Maclean, W. G. Kuschner, C. E. Rydzak, and D. K. Owens Accuracy of Positron Emission Tomography for Diagnosis of Pulmonary Nodules and Mass Lesions: A Meta-analysis JAMA, February 21, 2001; 285(7): 914 - 924. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Delbeke, W. H. Martin, J. A. Patton, and M. P. Sandler Value of Iterative Reconstruction,AttenuationCorrection,and Image Fusion in the Interpretation of FDG PET Images with an Integrated Dual-Head Coincidence Camera and X-Ray-based Attenuation Maps Radiology, January 1, 2001; 218(1): 163 - 171. [Abstract] [Full Text] |
||||
![]() |
V. Bousson, J.-L. Moretti, P. Weinmann, N. Safi, F. Tamgac, C. Groiselle, V. de Beco, Y. Hillali, D. Valeyre, and J.-L. Breau Assessment of Malignancy in Pulmonary Lesions: FDG Dual-Head Coincidence Gamma Camera Imaging in Association with Serum Tumor Marker Measurement J. Nucl. Med., November 1, 2000; 41(11): 1801 - 1807. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. T. Mastin, W. E. Drane, E. M. Harman, J. J. Fenton, and L. Quesenberry FDG SPECT in Patients With Lung Masses Chest, April 1, 1999; 115(4): 1012 - 1017. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |