Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Seltzer, S. E.
Right arrow Articles by Janoff, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seltzer, S. E.
Right arrow Articles by Janoff, A. S.

Radiology, Vol 194, 775-781, Copyright © 1995 by Radiological Society of North America


ARTICLES

Contrast material-carrying liposomes: biodistribution, clearance, and imaging characteristics

SE Seltzer, M Blau, LW Herman, RL Hooshmand, LA Herman, DF Adams, SR Minchey and AS Janoff
Department of Radiology, Brigham and Women's Hospital, Boston, MA 02115.

PURPOSE: To assess the biodistribution, clearance, and computed tomographic (CT) imaging characteristics of interdigitation-fusion (IF) liposomes that carry iotrolan in their aqueous phases. MATERIALS AND METHODS: Biodistribution and clearance of liposomes containing iotrolan produced with the IF method (IF vesicles) were assessed in rats. CT scans of rats and dogs were obtained after injection of IF vesicles at 100 and 250 mg of iodine per kilogram of body weight. RESULTS: A high initial uptake (63%-96% of the injected dose) was found in the liver and spleen. Liver elimination showed half-lives to be 12.9 days at 250 mg of iodine per kilogram, 10.9 days at 100 mg, and 8.7 days at 25 mg. At 250 mg of iodine per kilogram, the rats had an average of 96 HU of hepatic and 321 HU of splenic enhancement. The dogs had 116 HU of hepatic and 65 HU of splenic enhancement. CONCLUSION: IF liposomes have favorable biodistribution, clearance, and imaging characteristics as hepatosplenic contrast agents.


This article has been cited by other articles:


Home page
RadiologyHome page
P. Reimer
Tumor-targeted MR Contrast Agents: Hype or Future Hope?
Radiology, April 1, 2004; 231(1): 1 - 2.
[Full Text] [PDF]


Home page
RadiologyHome page
A. Luciani, J.-C. Olivier, O. Clement, N. Siauve, P.-Y. Brillet, B. Bessoud, F. Gazeau, I. F. Uchegbu, E. Kahn, G. Frija, et al.
Glucose-Receptor MR Imaging of Tumors: Study in Mice with PEGylated Paramagnetic Niosomes
Radiology, April 1, 2004; 231(1): 135 - 142.
[Abstract] [Full Text] [PDF]


Home page
J Biomater ApplHome page
R. Banerjee
Liposomes: Applications in Medicine
J Biomater Appl, July 1, 2001; 16(1): 3 - 21.
[Abstract] [PDF]


Home page
Drug Metab. Dispos.Home page
P. B. Jacobsen, A. Larsen, R. Konarboland, and T. Skotland
Biotransformation of Nonionic X-Ray Contrast Agents In Vivo and In Vitro
Drug Metab. Dispos., October 1, 1999; 27(10): 1205 - 1213.
[Abstract] [Full Text]


Home page
J. Biol. Chem.Home page
S. Raffy and J. Teissie
Electroinsertion of Glycophorin A in Interdigitation-Fusion Giant Unilamellar Lipid Vesicles
J. Biol. Chem., October 10, 1997; 272(41): 25524 - 25530.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.