Radiology, Vol 194, 843-850, Copyright © 1995 by Radiological Society of North America
ARTICLES |
F Jamar, PT Chapman, AA Harrison, RM Binns, DO Haskard and AM Peters
Department of Diagnostic Radiology, Royal Postgraduate Medical School, Hammersmith Hospital, London, England.
PURPOSE: To use imaging performed with an indium-111-labeled F(ab')2 fragment of monoclonal antibody that recognizes E-selectin (1.2B6) to evaluate inflammation. MATERIALS AND METHODS: After the in vivo immunoreactivity of In-111-F(ab')2 was verified, imaging experiments were conducted on pigs with induced arthritis of the right knee. In-111- labeled 1.2B6-F(ab')2, technetium-99m-hexamethylpropyleneamine oxime- labeled polymorphonuclear leukocytes (PMNs), and iodine-125-MOPC 21- labeled F(ab')2 (the control) were administered by means of intravenous injection. Scintigrams were obtained until 20 hours after injection, and tissue sampling was performed. RESULTS: Scintigrams showed uptake of 1.2B6 in the right knee but only faint filling of the joint space with PMNs. The right knee-to-left knee ratios on images obtained 20 hours after injection of the tracers were 10.8 +/- 3.6 for 1.2B6 and 1.1 +/- 0.4 for PMNs (P < .05). CONCLUSION: Endothelial cell immunotargeting with a radiolabeled anti-E-selectin F(ab')2 monoclonal antibody is feasible for use in imaging of inflammation.
This article has been cited by other articles:
![]() |
P. R. Reynolds, D. J. Larkman, D. O. Haskard, J. V. Hajnal, N. L. Kennea, A. J. T. George, and A. D. Edwards Detection of Vascular Expression of E-selectin in Vivo with MR Imaging Radiology, November 1, 2006; 241(2): 469 - 476. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Jamar, F. A. Houssiau, J.-P. Devogelaer, P. T. Chapman, D. O. Haskard, V. Beaujean, C. Beckers, D.-H. Manicourt, and A. M. Peters Scintigraphy using a technetium 99m-labelled anti-E-selectin Fab fragment in rheumatoid arthritis Rheumatology, January 1, 2002; 41(1): 53 - 61. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. W. Cockerill, T. Y. Huehns, A. Weerasinghe, C. Stocker, P. G. Lerch, N. E. Miller, and D. O. Haskard Elevation of Plasma High-Density Lipoprotein Concentration Reduces Interleukin-1-Induced Expression of E-Selectin in an In Vivo Model of Acute Inflammation Circulation, January 2, 2001; 103(1): 108 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Golledge, R. M. Greenhalgh, and A. H. Davies The Symptomatic Carotid Plaque Stroke, March 1, 2000; 31(3): 774 - 781. [Abstract] [Full Text] [PDF] |
||||
![]() |
M Bhatti, P Chapman, M Peters, D Haskard, and H J F Hodgson Visualising E-selectin in the detection and evaluation of inflammatory bowel disease Gut, July 1, 1998; 43(1): 40 - 47. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |