Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fleckenstein, J. L.
Right arrow Articles by Burns, D. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fleckenstein, J. L.
Right arrow Articles by Burns, D. K.

Radiology, Vol 195, 205-210, Copyright © 1995 by Radiological Society of North America


ARTICLES

High-voltage electric injury: assessment of muscle viability with MR imaging and Tc-99m pyrophosphate scintigraphy

JL Fleckenstein, DP Chason, FJ Bonte, RW Parkey, JL Hunt, GF Purdue and DK Burns
Department of Radiology, University of Texas Southwestern Medical Center, Dallas 75235-8896.

PURPOSE: To evaluate use of magnetic resonance (MR) imaging and technetium-99m pyrophosphate (PYP) scintigraphy in preoperative assessment of muscle viability after high-voltage electric injury. MATERIALS AND METHODS: Twelve injured limbs were studied. Immediate, equilibrium, and delayed Tc-99m PYP scintigrams and gadolinium-enhanced and unenhanced MR images were obtained. Imaging results were compared with clinical findings. RESULTS: Scintigraphy demonstrated nonperfusion in four limbs that were subsequently amputated, but MR imaging had poor sensitivity in nonperfused regions owing to lack of edema. Tc-99m PYP uptake increased at transition zones between normal and nonperfused regions. MR imaging allowed further characterization of these zones by demonstrating edema as enhancing (perfused) or nonenhancing (nonperfused). In all nonamputated limbs, edema showed enhancement. CONCLUSION: In high-voltage electric injury, gadolinium-enhanced MR imaging appears able to demonstrate zones of potential viability within radionuclide-avid tissue but has poor perfusion sensitivity when used alone.


This article has been cited by other articles:


Home page
Ann. N. Y. Acad. Sci.Home page
H. GISSEL, F. DESPA, J. COLLINS, D. MUSTAFI, K. ROJAHN, G. KARCZMAR, and R. LEE
Magnetic Resonance Imaging of Changes in Muscle Tissues after Membrane Trauma
Ann. N.Y. Acad. Sci., December 1, 2005; 1066(1): 272 - 285.
[Abstract] [Full Text] [PDF]


Home page
Ann. N. Y. Acad. Sci.Home page
E. E. TREDGET, H. A. SHANKOWSKY, and W. A. TILLEY
Electrical Injuries in Canadian Burn Care: Identification of Unsolved Problems
Ann. N.Y. Acad. Sci., October 30, 1999; 888(1): 75 - 87.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.