PURPOSE: To evaluate the accuracy and limitations of magnetic resonance (MR) angiographic screening for incidental intracranial aneurysms (IAs) in healthy individuals with a family history of IA. MATERIALS AND METHODS: Four hundred asymptomatic individuals in 68 families with a history of aneurysmal subarachnoid hemorrhage underwent MR angiography. Six families also had a history of polycystic kidney disease. A multislab, three-dimensional, time-of-flight sequence was used. Conventional angiography was performed to confirm positive MR angiographic findings. RESULTS: IAs were detected with MR angiography in 37 individuals, 32 of whom underwent conventional angiography. Intraobserver consistency was excellent (kappa = 0.96), and interobserver reproducibility was good to excellent (kappa = 0.59- 0.82). Both techniques showed similar results in the evaluation of size, localization, and orientation of aneurysms and visibility of the aneurysm neck. CONCLUSION: MR angiography is an accurate and feasible method of noninvasive screening for IAs in individuals at high risk. Conventional angiography is still necessary before operative treatment.
This article has been cited by other articles:
![]() |
D.Y. Yoon, K.J. Lim, C.S. Choi, B.M. Cho, S.M. Oh, and S.K. Chang Detection and Characterization of Intracranial Aneurysms with 16-Channel Multidetector Row CT Angiography: A Prospective Comparison of Volume-Rendered Images and Digital Subtraction Angiography AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 60 - 67. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Hirai, Y. Korogi, H. Arimura, S. Katsuragawa, M. Kitajima, M. Yamura, Y. Yamashita, and K. Doi Intracranial Aneurysms at MR Angiography: Effect of Computer-aided Diagnosis on Radiologists' Detection Performance Radiology, November 1, 2005; 237(2): 605 - 610. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Wills, A. Ronkainen, M. van der Voet, H. Kuivaniemi, K. Helin, E. Leinonen, J. Frosen, M. Niemela, J. Jaaskelainen, J. Hernesniemi, et al. Familial Intracranial Aneurysms: An Analysis of 346 Multiplex Finnish Families Stroke, June 1, 2003; 34(6): 1370 - 1374. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Okahara, H. Kiyosue, M. Yamashita, H. Nagatomi, H. Hata, T. Saginoya, Y. Sagara, and H. Mori Diagnostic Accuracy of Magnetic Resonance Angiography for Cerebral Aneurysms in Correlation With 3D-Digital Subtraction Angiographic Images: A Study of 133 Aneurysms Stroke, July 1, 2002; 33(7): 1803 - 1808. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. White, E. M. Teasdale, J. M. Wardlaw, and V. Easton Intracranial Aneurysms: CT Angiography and MR Angiography for Detection—Prospective Blinded Comparison in a Large Patient Cohort Radiology, June 1, 2001; 219(3): 739 - 749. [Abstract] [Full Text] [PDF] |
||||
![]() |
G.J. Hademenos, M.J. Alberts, I. Awad, M. Mayberg, T. Shephard, A. Jagoda, R.E. Latchaw, H.W. Todd, K. Viste, R. Starke, et al. Advances in the genetics of cerebrovascular disease and stroke Neurology, April 24, 2001; 56(8): 997 - 1008. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Boulin and L. Pierot Follow-up of Intracranial Aneurysms Treated with Detachable Coils: Comparison of Gadolinium-enhanced 3D Time-of-Flight MR Angiography and Digital Subtraction Angiography Radiology, April 1, 2001; 219(1): 108 - 113. [Abstract] [Full Text] |
||||
![]() |
J. van Gijn and G. J. E. Rinkel Subarachnoid haemorrhage: diagnosis, causes and management Brain, February 1, 2001; 124(2): 249 - 278. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. White, J. M. Wardlaw, and V. Easton Can Noninvasive Imaging Accurately Depict Intracranial Aneurysms? A Systematic Review Radiology, November 1, 2000; 217(2): 361 - 370. [Abstract] [Full Text] |
||||
![]() |
J. B. Bederson, I. A. Awad, D. O. Wiebers, D. Piepgras, E. C. Haley Jr, T. Brott, G. Hademenos, D. Chyatte, R. Rosenwasser, and C. Caroselli Recommendations for the Management of Patients With Unruptured Intracranial Aneurysms : A Statement for Healthcare Professionals From the Stroke Council of the American Heart Association Stroke, November 1, 2000; 31(11): 2742 - 2750. [Full Text] [PDF] |
||||
![]() |
J. B. Bederson, I. A. Awad, D. O. Wiebers, D. Piepgras, E. C. Haley Jr, T. Brott, G. Hademenos, D. Chyatte, R. Rosenwasser, and C. Caroselli Recommendations for the Management of Patients With Unruptured Intracranial Aneurysms : A Statement for Healthcare Professionals From the Stroke Council of the American Heart Association Circulation, October 31, 2000; 102(18): 2300 - 2308. [Full Text] [PDF] |
||||
![]() |
T. Metens, F. Rio, D. Balériaux, T. Roger, P. David, and G. Rodesch Intracranial Aneurysms: Detection with Gadolinium-enhanced Dynamic Three-dimensional MR Angiography-Initial Results Radiology, July 1, 2000; 216(1): 39 - 46. [Abstract] [Full Text] |
||||
![]() |
J. M. Wardlaw and P. M. White The detection and management of unruptured intracranial aneurysms Brain, February 1, 2000; 123(2): 205 - 221. [Abstract] [Full Text] [PDF] |
||||
![]() |
The Magnetic Resonance Angiography in Relatives of Risks and Benefits of Screening for Intracranial Aneurysms in First-Degree Relatives of Patients with Sporadic Subarachnoid Hemorrhage N. Engl. J. Med., October 28, 1999; 341(18): 1344 - 1350. [Abstract] [Full Text] [PDF] |
||||
![]() |
P.M. White, K.W. Lindsay, E. Teasdale, G.M. Teasdale, J.M. Wardlaw, M. M. Brown, F. Crawley, and A. Clifton Should We Screen for Familial Intracranial Aneurysm? • Response Stroke, October 1, 1999; 30 (10): 2238g - 2248. [Full Text] [PDF] |
||||
![]() |
V. J. Kähärä, S. K. Seppänen, P. S. Ryymin, P. Mattila, T. Kuurne, and E. M. Laasonen MR Angiography with Three-Dimensional Time-of-Flight and Targeted Maximum-Intensity-Projection Reconstructions in the Follow-up of Intracranial Aneurysms Embolized with Guglielmi Detachable Coils AJNR Am. J. Neuroradiol., September 1, 1999; 20(8): 1470 - 1475. [Abstract] [Full Text] |
||||
![]() |
T.-S. Chung, J.-Y. Joo, S.-K. Lee, D. Chien, and G. Laub Evaluation of Cerebral Aneurysms with High-Resolution MR Angiography Using a Section-Interpolation Technique: Correlation with Digital Subtraction Angiography AJNR Am. J. Neuroradiol., February 1, 1999; 20(2): 229 - 235. [Abstract] [Full Text] |
||||
![]() |
A. Ronkainen, H. Miettinen, K. Karkola, S. Papinaho, R. Vanninen, M. Puranen, and J. Hernesniemi Risk of Harboring an Unruptured Intracranial Aneurysm Stroke, February 1, 1998; 29(2): 359 - 362. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J. E. Rinkel, M. Djibuti, A. Algra, and J. van Gijn Prevalence and Risk of Rupture of Intracranial Aneurysms : A Systematic Review Stroke, January 1, 1998; 29(1): 251 - 256. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. I. Schievink Intracranial Aneurysms N. Engl. J. Med., January 2, 1997; 336(1): 28 - 40. [Full Text] [PDF] |
||||