|
|
||||||||
Radiology, Vol 195, 363-370, Copyright © 1995 by Radiological Society of North America
ARTICLES |
TC Winter 3rd, PC Freeny, HV Nghiem, SC Hommeyer, D Barr, AM Croghan, DM Coldwell, SJ Althaus and LA Mack
Department of Radiology, University of Washington Medical Center, Seattle 98195, USA.
PURPOSE: To assess the utility of three-dimensional (3D) hepatic helical computed tomographic (CT) arteriography as a replacement for conventional angiography in the evaluation of the arterial anatomy of patients being considered for liver transplantation. MATERIALS AND METHODS: Three-dimensional CT arteriograms were obtained in 115 patients. Seventeen patients also underwent conventional angiography, and 16 patients who did not undergo angiography underwent hepatic transplantation. RESULTS: Among the 3D CT arteriograms, 106 delineated the major arteries that supplied the liver. Nine were considered technical failures. In the 17 patients with angiographic correlation, there was only one marked disagreement with 3D CT arteriography. In the 16 patients with surgical correlation, no marked discrepancies were found. CONCLUSION: In transplantation candidates, successful 3D CT arteriography was as accurate as angiography in the assessment of hepatic arterial anatomy. It was also safer, more convenient, and more easily tolerated. Conventional CT plus 3D CT arteriography was only 25% as expensive as the cost of conventional CT and conventional angiography.
This article has been cited by other articles:
![]() |
S. K. An, J. M. Lee, K.-S. Suh, N. J. Lee, S. H. Kim, Y. J. Kim, J. K. Han, and B. I. Choi Gadobenate dimeglumine-enhanced liver MRI as the sole preoperative imaging technique: a prospective study of living liver donors. Am. J. Roentgenol., November 1, 2006; 187(5): 1223 - 1233. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. J. Stemmler, E. K. Paulson, F. J. Thornton, S. R. Winters, R. C. Nelson, and B. M. Clary Dual-Phase 3D MDCT Angiography for Evaluation of the Liver Before Hepatic Resection Am. J. Roentgenol., December 1, 2004; 183(6): 1551 - 1557. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Sahani, A. Mehta, M. Blake, S. Prasad, G. Harris, and S. Saini Preoperative Hepatic Vascular Evaluation with CT and MR Angiography: Implications for Surgery RadioGraphics, September 1, 2004; 24(5): 1367 - 1380. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Matsuki, H. Kani, F. Tatsugami, S. Yoshikawa, I. Narabayashi, S.-W. Lee, H. Shinohara, E. Nomura, and N. Tanigawa Preoperative Assessment of Vascular Anatomy Around the Stomach by 3D Imaging Using MDCT Before Laparoscopy-Assisted Gastrectomy Am. J. Roentgenol., July 1, 2004; 183(1): 145 - 151. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Guiney, J. B. Kruskal, J. Sosna, D. W. Hanto, S. N. Goldberg, and V. Raptopoulos Multi-Detector Row CT of Relevant Vascular Anatomy of the Surgical Plane in Split-Liver Transplantation Radiology, November 1, 2003; 229(2): 401 - 407. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Erbay, V. Raptopoulos, E. A. Pomfret, I. R. Kamel, and J. B. Kruskal Living Donor Liver Transplantation in Adults: Vascular Variants Important in Surgical Planning for Donors and Recipients Am. J. Roentgenol., July 1, 2003; 181(1): 109 - 114. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Tanikake, T. Shimizu, I. Narabayashi, M. Matsuki, K. Masuda, K. Yamamoto, Y. Uesugi, and S. Yoshikawa Three-dimensional CT Angiography of the Hepatic Artery: Use of Multi-Detector Row Helical CT and a Contrast Agent Radiology, June 1, 2003; 227(3): 883 - 889. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Schroeder, S. Nadalin, J. Stattaus, J. F. Debatin, M. Malago, and S. G. Ruehm Potential Living Liver Donors: Evaluation with an All-in-One Protocol with Multi-Detector Row CT Radiology, August 1, 2002; 224(2): 586 - 591. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Sahani, S. Saini, C. Pena, S. Nichols, S. R. Prasad, P. F. Hahn, E. F. Halpern, K. K. Tanabe, and P. R. Mueller Using Multidetector CT for Preoperative Vascular Evaluation of Liver Neoplasms: Technique and Results Am. J. Roentgenol., July 1, 2002; 179(1): 53 - 59. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Kawata, T. Murakami, T. Kim, M. Hori, M. P. Federle, S. Kumano, E. Sugihara, S. Makino, H. Nakamura, and M. Kudo Multidetector CT: Diagnostic Impact of Slice Thickness on Detection of Hypervascular Hepatocellular Carcinoma Am. J. Roentgenol., July 1, 2002; 179(1): 61 - 66. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. K. Pannu, W. R. Maley, and E. K. Fishman Liver Transplantation: Preoperative CT Evaluation RadioGraphics, October 1, 2001; 21(90001): S133 - 146. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Matsumoto, M. Kitamoto, M. Imamura, T. Nakanishi, C. Ono, K. Ito, and G. Kajiyama Three-Dimensional Portography Using Multislice Helical CT Is Clinically Useful for Management of Gastric Fundic Varices Am. J. Roentgenol., April 1, 2001; 176(4): 899 - 905. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. T. Lavelle, V. S. Lee, N. M. Rofsky, G. A. Krinsky, and J. C. Weinreb Dynamic Contrast-enhanced Three-dimensional MR Imaging of Liver Parenchyma: Source Images and Angiographic Reconstructions to Define Hepatic Arterial Anatomy Radiology, February 1, 2001; 218(2): 389 - 394. [Abstract] [Full Text] |
||||
![]() |
I. R. Kamel, J. B. Kruskal, E. A. Pomfret, M. T. Keogan, G. Warmbrand, and V. Raptopoulos Impact of Multidetector CT on Donor Selection and Surgical Planning Before Living Adult Right Lobe Liver Transplantation Am. J. Roentgenol., January 1, 2001; 176(1): 193 - 200. [Abstract] [Full Text] |
||||
![]() |
S. Katyal, J. H. Oliver III, D. G. Buck, and M. P. Federle Detection of Vascular Complications After Liver Transplantation: Early Experience in Multislice CT Angiography with Volume Rendering Am. J. Roentgenol., December 1, 2000; 175(6): 1735 - 1739. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee, M. T. Lavelle, N. M. Rofsky, G. Laub, D. M. Thomasson, G. A. Krinsky, and J. C. Weinreb Hepatic MR Imaging with a Dynamic Contrast-enhanced Isotropic Volumetric Interpolated Breath-hold Examination: Feasibility, Reproducibility, and Technical Quality Radiology, May 1, 2000; 215(2): 365 - 372. [Abstract] [Full Text] |
||||
![]() |
Y. Watanabe, M. Dohke, T. Ishimori, Y. Amoh, A. Okumura, K. Oda, T. Hayashi, A. Hiyama, and Y. Dodo Pseudo-obstruction of the Extrahepatic Bile Duct Due to Artifact from Arterial Pulsatile Compression: A Diagnostic Pitfall of MR Cholangiopancreatography Radiology, March 1, 2000; 214(3): 856 - 860. [Abstract] [Full Text] |
||||
![]() |
P. S. Calhoun, B. S. Kuszyk, D. G. Heath, J. C. Carley, and E. K. Fishman Three-dimensional Volume Rendering of Spiral CT Data: Theory and Method RadioGraphics, May 1, 1999; 19(3): 745 - 764. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Kopka, J. Rodenwaldt, R. Vosshenrich, U. Fischer, B. Renner, T. Lorf, J. Graessner, B. Ringe, and E. Grabbe Hepatic Blood Supply: Comparison of Optimized Dual Phase Contrast-enhanced Three-dimensional MR Angiography and Digital Subtraction Angiography Radiology, April 1, 1999; 211(1): 51 - 58. [Abstract] [Full Text] |
||||
![]() |
S. G. Lalka, M. S. Johnson, and S. M. Stockberger Evaluation of Abdominal Aortic Aneurysms Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 1999; 10(1): 43 - 68. [Abstract] [PDF] |
||||
![]() |
S. Takahashi, T. Murakami, M. Takamura, T. Kim, M. Hori, Y. Narumi, H. Nakamura, and M. Kudo Multi-Detector Row Helical CT Angiography of Hepatic Vessels: Depiction with Dual-arterial Phase Acquisition during Single Breath Hold Radiology, January 1, 2002; 222(1): 81 - 88. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |