|
|
||||||||
Radiology, Vol 195, 497-500, Copyright © 1995 by Radiological Society of North America
ARTICLES |
SF Quinn, RC Sheley, TA Demlow and J Szumowski
Department of Radiology, Good Samaritan Hospital and Medical Center, Portland, OR 97210, USA.
PURPOSE: To evaluate the diagnostic accuracy of fat-suppressed magnetic resonance (MR) imaging of rotator cuff tears in a large symptomatic population. MATERIALS AND METHODS: One hundred patients underwent both MR imaging and arthroscopy of the shoulder. Ninety-two patients underwent fat-suppressed conventional spin-echo MR imaging (repetition time msec/echo time msec = 2,500/20, 60), and eight patients underwent fat-suppressed, fast spin-echo MR imaging (2,000/80). RESULTS: With data combined for complete and partial tears of the rotator cuff (n = 31), MR imaging had an accuracy of 93%; sensitivity, 84%; and specificity, 97%. Seventeen of 20 complete tears and nine of 11 partial tears were properly identified with MR imaging. Two partial tears were not detected and three complete tears were incorrectly called partial tears at MR imaging. Of two false-positive MR imaging findings, one was called a complete tear and the other, a partial tear. CONCLUSION: Fat- suppressed MR imaging has high diagnostic accuracy in evaluating tears of the rotator cuff tendon.
This article has been cited by other articles:
![]() |
L. Silva, J. L. Andreu, P. Munoz, M. Pastrana, I. Millan, J. Sanz, C. Barbadillo, and M. Fernandez-Castro Accuracy of physical examination in subacromial impingement syndrome Rheumatology, May 1, 2008; 47(5): 679 - 683. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. E. Spencer Jr, W. R. Dunn, R. W. Wright, B. R. Wolf, K. P. Spindler, E. McCarty, C. B. Ma, G. Jones, M. Safran, G. B. Holloway, et al. Interobserver Agreement in the Classification of Rotator Cuff Tears Using Magnetic Resonance Imaging Am. J. Sports Med., January 1, 2008; 36(1): 99 - 103. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Hambly, P. Fitzpatrick, P. MacMahon, and S. Eustace Rotator Cuff Impingement: Correlation Between Findings on MRI and Outcome After Fluoroscopically Guided Subacromial Bursography and Steroid Injection Am. J. Roentgenol., November 1, 2007; 189(5): 1179 - 1184. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Farber, L. Fayad, T. Johnson, B. Cascio, M. Shindle, P. Neubauer, and A. J. Khanna Magnetic Resonance Imaging of the Shoulder. Current Techniques and Spectrum of Disease J. Bone Joint Surg. Am., December 1, 2006; 88(suppl_4): 64 - 79. [Full Text] [PDF] |
||||
![]() |
T. Herold, M. Bachthaler, O. W. Hamer, R. Hente, S. Feuerbach, C. Fellner, M. Strotzer, M. Lenhart, and C. Paetzel Indirect MR Arthrography of the Shoulder: Use of Abduction and External Rotation to Detect Full- and Partial-Thickness Tears of the Supraspinatus Tendon Radiology, July 1, 2006; 240(1): 152 - 160. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E. MADDEN The Magic-angle Effect of the Supraspinatus Tendon. Radiol. Technol., May 1, 2006; 77(5): 357 - 365. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. D. Traughber, S. Merandi, and K. A. Traughber MR Arthrography Is Not Proven to Be Preferred Baseline MRI Examination Am. J. Roentgenol., January 1, 2006; 186(1): 265 - 266. [Full Text] [PDF] |
||||
![]() |
W. B. Stetson, T. Phillips, and A. Deutsch The Use of Magnetic Resonance Arthrography to Detect Partial-Thickness Rotator Cuff Tears J. Bone Joint Surg. Am., December 1, 2005; 87(suppl_2): 81 - 88. [Full Text] [PDF] |
||||
![]() |
M. J. Matava, D. B. Purcell, and J. R. Rudzki Partial-Thickness Rotator Cuff Tears Am. J. Sports Med., September 1, 2005; 33(9): 1405 - 1417. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Kijowski, J. M. Farber, J. Medina, W. Morrison, J. Ying, and K. Buckwalter Comparison of Fat-Suppressed T2-Weighted Fast Spin-Echo Sequence and Modified STIR Sequence in the Evaluation of the Rotator Cuff Tendon Am. J. Roentgenol., August 1, 2005; 185(2): 371 - 378. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kassarjian, M. Torriani, H. Ouellette, and W. E. Palmer Intramuscular Rotator Cuff Cysts: Association with Tendon Tears on MRI and Arthroscopy Am. J. Roentgenol., July 1, 2005; 185(1): 160 - 165. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. G. Sanders and M. D. Miller A Systematic Approach to Magnetic Resonance Imaging Interpretation of Sports Medicine Injuries of the Shoulder Am. J. Sports Med., July 1, 2005; 33(7): 1088 - 1105. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Charousset, L. Bellaiche, L. D. Duranthon, and J. Grimberg Accuracy of CT arthrography in the assessment of tears of the rotator cuff J Bone Joint Surg Br, June 1, 2005; 87-B(6): 824 - 828. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. W. A. Pfirrmann, M. R. Schmid, M. Zanetti, B. Jost, C. Gerber, and J. Hodler Assessment of Fat Content in Supraspinatus Muscle with Proton MR Spectroscopy in Asymptomatic Volunteers and Patients with Supraspinatus Tendon Lesions Radiology, September 1, 2004; 232(3): 709 - 715. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. Teefey, D. A. Rubin, W. D. Middleton, C. F. Hildebolt, R. A. Leibold, and K. Yamaguchi Detection and Quantification of Rotator Cuff Tears. Comparison of Ultrasonographic, Magnetic Resonance Imaging, and Arthroscopic Findings in Seventy-one Consecutive Cases J. Bone Joint Surg. Am., April 1, 2004; 86(4): 708 - 716. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K Walsworth, J. T Mills III, and L. A Michener Diagnosing Suprascapular Neuropathy in Patients With Shoulder Dysfunction: A Report of 5 Cases Physical Therapy, April 1, 2004; 84(4): 359 - 372. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Strobel, M. Zanetti, L. Nagy, and J. Hodler Suspected Rotator Cuff Lesions: Tissue Harmonic Imaging versus Conventional US of the Shoulder Radiology, January 1, 2004; 230(1): 243 - 249. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. P. Beall, E. E. Williamson, J. Q. Ly, M. C. Adkins, R. L. Emery, T. P. Jones, and C. M. Rowland Association of Biceps Tendon Tears with Rotator Cuff Abnormalities: Degree of Correlation with Tears of the Anterior and Superior Portions of the Rotator Cuff Am. J. Roentgenol., March 1, 2003; 180(3): 633 - 639. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Y. Lee and J. K. Lee Horizontal Component of Partial-Thickness Tears of Rotator Cuff: Imaging Characteristics and Comparison of ABER View with Oblique Coronal View at MR Arthrography— Initial Results Radiology, August 1, 2002; 224(2): 470 - 476. [Abstract] [Full Text] [PDF] |
||||
![]() |
E Naredo, P Aguado, E De Miguel, J Uson, L Mayordomo, J Gijon-Banos, and E Martin-Mola Painful shoulder: comparison of physical examination and ultrasonographic findings Ann Rheum Dis, February 1, 2002; 61(2): 132 - 136. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Miniaci, A. T. Mascia, D. C. Salonen, and E. J. Becker Magnetic Resonance Imaging of the Shoulder in Asymptomatic Professional Baseball Pitchers Am. J. Sports Med., January 1, 2002; 30(1): 66 - 73. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. L. Spielmann, B. B. Forster, P. Kokan, R. H. Hawkins, and D. L. Janzen Shoulder after Rotator Cuff Repair: MR Imaging Findings in Asymptomatic Individuals-Initial Experience Radiology, December 1, 1999; 213(3): 705 - 708. [Abstract] [Full Text] |
||||
![]() |
C. W. A. Pfirrmann, M. Zanetti, D. Weishaupt, C. Gerber, and J. Hodler Subscapularis Tendon Tears: Detection and Grading at MR Arthrography Radiology, December 1, 1999; 213(3): 709 - 714. [Abstract] [Full Text] |
||||
![]() |
C. J. Seibold, T. A. Mallisee, S. J. Erickson, M. D. Boynton, W. G. Raasch, and M. E. Timins Rotator Cuff: Evaluation with US and MR Imaging RadioGraphics, May 1, 1999; 19(3): 685 - 705. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. HERZOG Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Magnetic Resonance Imaging of the Shoulder*{{dagger}} J. Bone Joint Surg. Am., June 1, 1997; 79(6): 934 - 53. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |