Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Quinn, S. F.
Right arrow Articles by Szumowski, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Quinn, S. F.
Right arrow Articles by Szumowski, J.

Radiology, Vol 195, 497-500, Copyright © 1995 by Radiological Society of North America


ARTICLES

Rotator cuff tendon tears: evaluation with fat-suppressed MR imaging with arthroscopic correlation in 100 patients

SF Quinn, RC Sheley, TA Demlow and J Szumowski
Department of Radiology, Good Samaritan Hospital and Medical Center, Portland, OR 97210, USA.

PURPOSE: To evaluate the diagnostic accuracy of fat-suppressed magnetic resonance (MR) imaging of rotator cuff tears in a large symptomatic population. MATERIALS AND METHODS: One hundred patients underwent both MR imaging and arthroscopy of the shoulder. Ninety-two patients underwent fat-suppressed conventional spin-echo MR imaging (repetition time msec/echo time msec = 2,500/20, 60), and eight patients underwent fat-suppressed, fast spin-echo MR imaging (2,000/80). RESULTS: With data combined for complete and partial tears of the rotator cuff (n = 31), MR imaging had an accuracy of 93%; sensitivity, 84%; and specificity, 97%. Seventeen of 20 complete tears and nine of 11 partial tears were properly identified with MR imaging. Two partial tears were not detected and three complete tears were incorrectly called partial tears at MR imaging. Of two false-positive MR imaging findings, one was called a complete tear and the other, a partial tear. CONCLUSION: Fat- suppressed MR imaging has high diagnostic accuracy in evaluating tears of the rotator cuff tendon.


This article has been cited by other articles:


Home page
Rheumatology (Oxford)Home page
L. Silva, J. L. Andreu, P. Munoz, M. Pastrana, I. Millan, J. Sanz, C. Barbadillo, and M. Fernandez-Castro
Accuracy of physical examination in subacromial impingement syndrome
Rheumatology, May 1, 2008; 47(5): 679 - 683.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
E. E. Spencer Jr, W. R. Dunn, R. W. Wright, B. R. Wolf, K. P. Spindler, E. McCarty, C. B. Ma, G. Jones, M. Safran, G. B. Holloway, et al.
Interobserver Agreement in the Classification of Rotator Cuff Tears Using Magnetic Resonance Imaging
Am. J. Sports Med., January 1, 2008; 36(1): 99 - 103.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. Hambly, P. Fitzpatrick, P. MacMahon, and S. Eustace
Rotator Cuff Impingement: Correlation Between Findings on MRI and Outcome After Fluoroscopically Guided Subacromial Bursography and Steroid Injection
Am. J. Roentgenol., November 1, 2007; 189(5): 1179 - 1184.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
A. Farber, L. Fayad, T. Johnson, B. Cascio, M. Shindle, P. Neubauer, and A. J. Khanna
Magnetic Resonance Imaging of the Shoulder. Current Techniques and Spectrum of Disease
J. Bone Joint Surg. Am., December 1, 2006; 88(suppl_4): 64 - 79.
[Full Text] [PDF]


Home page
RadiologyHome page
T. Herold, M. Bachthaler, O. W. Hamer, R. Hente, S. Feuerbach, C. Fellner, M. Strotzer, M. Lenhart, and C. Paetzel
Indirect MR Arthrography of the Shoulder: Use of Abduction and External Rotation to Detect Full- and Partial-Thickness Tears of the Supraspinatus Tendon
Radiology, July 1, 2006; 240(1): 152 - 160.
[Abstract] [Full Text] [PDF]


Home page
radtechHome page
M. E. MADDEN
The Magic-angle Effect of the Supraspinatus Tendon.
Radiol. Technol., May 1, 2006; 77(5): 357 - 365.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. D. Traughber, S. Merandi, and K. A. Traughber
MR Arthrography Is Not Proven to Be Preferred Baseline MRI Examination
Am. J. Roentgenol., January 1, 2006; 186(1): 265 - 266.
[Full Text] [PDF]


Home page
JBJSHome page
W. B. Stetson, T. Phillips, and A. Deutsch
The Use of Magnetic Resonance Arthrography to Detect Partial-Thickness Rotator Cuff Tears
J. Bone Joint Surg. Am., December 1, 2005; 87(suppl_2): 81 - 88.
[Full Text] [PDF]


Home page
Am J Sports MedHome page
M. J. Matava, D. B. Purcell, and J. R. Rudzki
Partial-Thickness Rotator Cuff Tears
Am. J. Sports Med., September 1, 2005; 33(9): 1405 - 1417.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Kijowski, J. M. Farber, J. Medina, W. Morrison, J. Ying, and K. Buckwalter
Comparison of Fat-Suppressed T2-Weighted Fast Spin-Echo Sequence and Modified STIR Sequence in the Evaluation of the Rotator Cuff Tendon
Am. J. Roentgenol., August 1, 2005; 185(2): 371 - 378.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Kassarjian, M. Torriani, H. Ouellette, and W. E. Palmer
Intramuscular Rotator Cuff Cysts: Association with Tendon Tears on MRI and Arthroscopy
Am. J. Roentgenol., July 1, 2005; 185(1): 160 - 165.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
T. G. Sanders and M. D. Miller
A Systematic Approach to Magnetic Resonance Imaging Interpretation of Sports Medicine Injuries of the Shoulder
Am. J. Sports Med., July 1, 2005; 33(7): 1088 - 1105.
[Abstract] [Full Text] [PDF]


Home page
J Bone Joint Surg BrHome page
C. Charousset, L. Bellaiche, L. D. Duranthon, and J. Grimberg
Accuracy of CT arthrography in the assessment of tears of the rotator cuff
J Bone Joint Surg Br, June 1, 2005; 87-B(6): 824 - 828.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. W. A. Pfirrmann, M. R. Schmid, M. Zanetti, B. Jost, C. Gerber, and J. Hodler
Assessment of Fat Content in Supraspinatus Muscle with Proton MR Spectroscopy in Asymptomatic Volunteers and Patients with Supraspinatus Tendon Lesions
Radiology, September 1, 2004; 232(3): 709 - 715.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
S. A. Teefey, D. A. Rubin, W. D. Middleton, C. F. Hildebolt, R. A. Leibold, and K. Yamaguchi
Detection and Quantification of Rotator Cuff Tears. Comparison of Ultrasonographic, Magnetic Resonance Imaging, and Arthroscopic Findings in Seventy-one Consecutive Cases
J. Bone Joint Surg. Am., April 1, 2004; 86(4): 708 - 716.
[Abstract] [Full Text] [PDF]


Home page
ptjournalHome page
M. K Walsworth, J. T Mills III, and L. A Michener
Diagnosing Suprascapular Neuropathy in Patients With Shoulder Dysfunction: A Report of 5 Cases
Physical Therapy, April 1, 2004; 84(4): 359 - 372.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Strobel, M. Zanetti, L. Nagy, and J. Hodler
Suspected Rotator Cuff Lesions: Tissue Harmonic Imaging versus Conventional US of the Shoulder
Radiology, January 1, 2004; 230(1): 243 - 249.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. P. Beall, E. E. Williamson, J. Q. Ly, M. C. Adkins, R. L. Emery, T. P. Jones, and C. M. Rowland
Association of Biceps Tendon Tears with Rotator Cuff Abnormalities: Degree of Correlation with Tears of the Anterior and Superior Portions of the Rotator Cuff
Am. J. Roentgenol., March 1, 2003; 180(3): 633 - 639.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Y. Lee and J. K. Lee
Horizontal Component of Partial-Thickness Tears of Rotator Cuff: Imaging Characteristics and Comparison of ABER View with Oblique Coronal View at MR Arthrography— Initial Results
Radiology, August 1, 2002; 224(2): 470 - 476.
[Abstract] [Full Text] [PDF]


Home page
Ann Rheum DisHome page
E Naredo, P Aguado, E De Miguel, J Uson, L Mayordomo, J Gijon-Banos, and E Martin-Mola
Painful shoulder: comparison of physical examination and ultrasonographic findings
Ann Rheum Dis, February 1, 2002; 61(2): 132 - 136.
[Abstract] [Full Text] [PDF]


Home page
Am J Sports MedHome page
A. Miniaci, A. T. Mascia, D. C. Salonen, and E. J. Becker
Magnetic Resonance Imaging of the Shoulder in Asymptomatic Professional Baseball Pitchers
Am. J. Sports Med., January 1, 2002; 30(1): 66 - 73.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. L. Spielmann, B. B. Forster, P. Kokan, R. H. Hawkins, and D. L. Janzen
Shoulder after Rotator Cuff Repair: MR Imaging Findings in Asymptomatic Individuals-Initial Experience
Radiology, December 1, 1999; 213(3): 705 - 708.
[Abstract] [Full Text]


Home page
RadiologyHome page
C. W. A. Pfirrmann, M. Zanetti, D. Weishaupt, C. Gerber, and J. Hodler
Subscapularis Tendon Tears: Detection and Grading at MR Arthrography
Radiology, December 1, 1999; 213(3): 709 - 714.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
C. J. Seibold, T. A. Mallisee, S. J. Erickson, M. D. Boynton, W. G. Raasch, and M. E. Timins
Rotator Cuff: Evaluation with US and MR Imaging
RadioGraphics, May 1, 1999; 19(3): 685 - 705.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
R. J. HERZOG
Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Magnetic Resonance Imaging of the Shoulder*{{dagger}}
J. Bone Joint Surg. Am., June 1, 1997; 79(6): 934 - 53.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1995 by the Radiological Society of North America.